Description
1. Commercial Introduction
The non-pivoting 3M™ 9690 blades are the reference consumable replacement for the rechargeable 3M™ Surgical Clipper surgical razor (code 27054 / model 3M 9667L-E). Designed for the operating theatre, emergency and trauma services, they guarantee preoperative shaving of head and body hair with a clean, uniform finish, and their single-use, individually sealed format ensures maximum hygiene between patients. An essential consumable in surgical site preparation protocols.
2. Technical explanation of the equipment
Each 3M™ 9690 blade is individually sealed and is indicated for dense head and body hair. Its non-pivoting design removes hair quickly and effectively in trauma and neurosurgery cases, where maximum control of the area to be shaved is required. When attached to the 3M™ Surgical Clipper razor, the cutting blade works separated from the skin, minimising the possibility of cuts and abrasions and helping to reduce the risk of surgical site infection (SSI). The handle incorporates a long-lasting lithium-ion (Li-ion) battery with a charge indicator light, approximately 160 minutes of autonomy per 4-hour recharge, an ergonomic handle that is easy to grip, and a submersible body (IP X7 rating: submersible in water at no more than 1 m for 30 minutes) for simple, complete cleaning.
3. Technical Specifications
Features of the razor (code 27054) with non-pivoting 3M 9690 blades:
- Ergonomic handle, easy to grip
- Blade with easy attachment
- Removes hair quickly and effectively in trauma and neurosurgery cases
- Blade separated from the skin that minimises cuts and abrasions, reducing the risk of surgical site infections (SSI)
- Long-lasting lithium-ion (Li-ion) battery with battery indicator light
- Approximately 160 minutes of autonomy per full charge (4-hour recharge)
- Submersible for easy cleaning (IP X7 rating: submersible in water at no more than 1 m for 30 minutes)
| Brand | 3M |
|---|---|
| Manufacturer reference | 9690 (non-pivoting blades) |
| Compatibility | Surgical razor 3M™ Surgical Clipper (code 27054 · 3M 9667L-E) |
| Sales unit | Box of 20 pcs (box of 20 units) |
| Device type | Medical device (medical device) |
| Device class | I |
| CND | V010302 |
| EAN | 0707387575212 |
| Available references | Description |
|---|---|
| 3M 9690 surgical blades – non-pivoting (GM27056 · Ref. 27056) | Box of 20 units. Single-use, individually sealed; for trauma and neurosurgery; dense head and body hair |
| 3M 9660 surgical blades – pivoting (GM27055 · Ref. 27055) | Box of 50 units. Pivoting head, single-use, individually sealed |
| 3M Surgical Clipper surgical razor kit + charger (GM27054 · Ref. 27054 · 3M 9667L-E) | 1 kit. Rechargeable handle + charger; compatible with 9660 and 9690 blades |
4. Equivalences and Cross-References
This product corresponds to the original reference Ref. 27056 (SKU Cahnos GM27056) and to code 3M 9690, and is the blade replacement for the 3M™ Surgical Clipper 9667L-E surgical razor kit (code 27054, SKU GM27054). The same razor also accepts the pivoting 3M 9660 blades (code 27055, SKU GM27055). There is no manufacturer-validated equivalence table cross-referencing this reference 1:1 with other manufacturers; as a functional alternative in the same category (electric preoperative preparation trimming), the Medline Ergosafe Clipper surgical trimmer (ref. DYND70800EU) may be cited, although any substitution must be checked with the Cahnos technical-commercial department before use in protocols or tenders.
5. Selection tips and variants of interest
Select the non-pivoting 3M 9690 blade (GM27056) for trauma and neurosurgery, where rapid, controlled removal of dense head and body hair is required, and the pivoting 3M 9660 blade (GM27055) when a shave that adapts to the contours of the body is sought, on all types of hair, dry or wet, in a single pass. The 3M™ Surgical Clipper razor with charger (GM27054) is the indicated choice for equipping new operating theatre stations or replacing existing units. As these are single-use consumables sealed individually, it is recommended to plan sufficient stock according to the surgical volume of the service and to keep the handle charged and clean after each use (submersible, IP X7). For volume orders, tenders or bids, contact the Cahnos technical-commercial team to confirm the reference and supply conditions.





Reviews