Description
1. Commercial Introduction
The disposable scalpel No. 16, of our own manufacture, distributed by Cahnos, is the ready-to-use solution your facility needs for making short, precise and controlled incisions in organic tissue with the utmost guarantee of sterility. Each unit is supplied sterile, in a peelable individual package and prepared for single-use, eliminating re-sterilisation costs and the risk of cross-contamination between patients.
Its stainless steel blade, pre-mounted on an ergonomic ABS handle, offers a consistent and reproducible edge in every procedure, with a firm grip even with wet surgical gloves. It is the usual choice in operating theatres, emergency departments, ambulatory minor surgery, primary care, dermatology, podiatry and veterinary.
2. Technical explanation of the product and procedure
Blade size No. 16 follows the classic industry numbering (Bard-Parker system) shared by the main manufacturers: it belongs to the group of small blades (9 to 17) that fit on fitment No. 3 handles according to standard ISO 7740:1985, as opposed to large blades (18 to 36) that use fitment No. 4. It is a size with a contained profile, intended for short, precise incisions on skin and soft tissue, as well as for fine dissection manoeuvres.
Unlike loose blades, this scalpel integrates blade and handle into a single disposable body: the stainless steel blade is pre-mounted on an ABS handle with a fluted handle (fluted finger grips) that ensures a firm hold, and the edge is protected by an LDPE guard until the exact moment of use. The product is supplied sterile by gamma radiation (minimum dose 2.5 Mrad), is single-use and must not be re-sterilised; the size is marked on each unit or on its blister to facilitate traceability and stock replenishment.
3. Technical Specifications
| Parameter | Specification |
| Brand / Distributor | Cahnos (Soluciones Hospitalarias) |
| Manufacture | Own (Cahnos) |
| Reference Cahnos (SKU) | PDSS16 |
| Factory reference | PDSS16 (range of disposable scalpels «Disposable Scalpel», official 2025 catalogue) |
| Blade number | 16 (Bard-Parker industry numbering) |
| Profile / geometry | Small precision blade (size group 9 to 17) |
| Fitment | No. 3 (small blades, according to ISO 7740:1985) |
| Blade material | Stainless steel |
| Handle material | Medical-grade ABS, non-slip fluted handle |
| Blade protection | LDPE protective guard, removable at time of use |
| Sterilisation | Gamma radiation (minimum dose 2.5 Mrad) |
| Individual packaging | Sterile peel pouch |
| Presentation | Dispenser box of 10 units |
| Inner box dimensions | 21 × 7 × 3 cm (10 units) |
| Shelf life | 5 years from date of manufacture |
| Latex-free | Yes |
| Use | Single-use — do not reuse, do not re-sterilise |
| Application | Short, controlled incisions in organic tissue; minor surgery, emergency, dermatology, podiatry, veterinary and incision and puncture kits |
| Classification | Sterile single-use medical device, with CE marking |
Range of disposable scalpels (stainless steel blade):
| Size group | Fitment | Available sizes |
| Small blades | No. 3 | 9, 10, 10A, 11, 11K, 12, 13, 14, 15, 15B, 15C, 16 (this product), 17 |
| Large blades | No. 4 | 18, 19, 20, 21, 22, 22A, 23, 24, 25, 36 |
Packaging data: dispensing inner box 21 × 7 × 3 cm · 10 units per box · export carton 44 × 37 × 33 cm · 100 boxes per carton.
4. Equivalences and Cross-References
The Cahnos reference PDSS16 corresponds to size 16 of the disposable scalpel range; the factory code matches the distributor’s SKU and has been verified against the manufacturer’s own catalogue (Bard-Parker numbering, fitment No. 3, dispensing box of 10 units).
There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders. Figure 16 with integrated handle is an uncommon size in the verified disposable lines of the sector: it does not appear in the official catalogues of complete disposable scalpels from Feather / pfm medical (Standard Scalpel range, figs. 10, 11, 12, 15, 20 to 25, 12d, 14 and 15c), from OR / Präzisa Plus (P. J. Dahlhausen, figs. 10, 11, 12, 15, 18, 19, 20, 21, 22, 23 and 24) nor from Heinz Herenz (sizes 10, 11, 12, 15 and 20 to 24). Nor does it appear among the sizes in the Bard-Parker disposable scalpel catalogue from Aspen Surgical (sizes 10, 11, 12, 12B, 15, 20, 21 and 23). Therefore, any substitution must be considered comparable at category level and not interchangeable 1:1, always verifying in the manufacturer’s official data sheet the availability of size 16, the blade material, sterility, fitment and handle design. As homologous families in the sector with disposable stainless steel blade scalpels, Swann-Morton (United Kingdom), Feather / pfm medical (Japan / Germany), Aspen Surgical – Bard-Parker (USA) and B. Braun / Aesculap (Germany) can be cited.
5. Selection tips and variants of interest
Select the blade size according to the procedure: small sizes with fitment No. 3 (9 to 17) cover short, precise incisions in minor surgery, dermatology and podiatry, while large sizes with fitment No. 4 (18 onwards) are reserved for wide skin incisions and general surgery. Size 16 falls into that group of small blades, with the same handle ergonomics as the rest of the range.
Use and disposal: remove the LDPE guard just before the procedure and, after use, manage the sharp waste in sharps containers for healthcare waste in accordance with current regulations. Do not re-sterilise. Storage: keep the boxes in a dry place at room temperature, respecting the 5-year expiry from manufacture and checking the integrity of the individual package before each use.
Cahnos variants: in the same disposable range, other sizes are offered such as No. 15B (PDSS15B) or No. 17 (PDSS17); large sizes start at No. 18 (PDSS18). If your facility prioritises protection against accidental cuts, it has the retractable safety scalpel No. 16 (SKU PSF16, biosafety range) with anti-reuse lock and integrated metric ruler; if you prefer the loose blade format with reusable handle, the steel blade No. 16 (SKU PCS16) fits on fitment No. 3 handles according to ISO 7740.
For volume orders, public tenders or standardisation protocols, contact our technical-commercial team for special conditions and personalised advice.



Reviews