Description
1. Commercial Introduction
The T-type IUD Silver plata CU-380-AG normal (Ref. PT200N) is a copper intrauterine contraceptive device with a silver core, designed for gynaecology professionals, family planning units, reproductive health centres and emergency services seeking a long-acting, reliable and fully reversible method. Its ‘normal’ format is indicated for most patients with a standard uterine cavity, offering 5 years of effective protection without interfering with breastfeeding. Sold per unit, sterile and ready to use.
2. Technical explanation of the device
It is an intrauterine contraceptive (IUD) with a T-shaped base frame made of low-density polyethylene (LDPE), on whose stem a wire of oxygen-free electronic copper (OFE) with 99.99% purity is wound, with a silver core of 99.99% purity. The silver core provides greater mechanical strength of the wire against fragmentation and corrosion, maintaining a stable release of copper ions over time. The device is loaded into a high-density polyethylene insertion tube and introduced into the uterine cavity by means of a solid rod, being placed at the uterine fundus. The nylon extraction threads allow control and subsequent removal of the device. Protection is reversed at the moment of removal, making it a fully reversible method.
3. Technical Specifications
| Property | Detail |
|---|---|
| Product type | Copper contraceptive intrauterine device (IUD) with silver core |
| Model | CU-380-AG normal |
| Reference Cahnos | PT200N |
| Copper surface | 380 mm² |
| Wire | OFE copper 99.99% with silver core 99.99%, Ø 0.40 ± 0.01 mm |
| Structure | Low-density polyethylene (LDPE); length 31.50–33.50 mm × width 30.00–32.00 mm; stem Ø 1.45–1.65 mm |
| Insertion tube | High-density polyethylene (HDPE), length 200–204 mm, ext. Ø 3.70–3.90 mm |
| Solid rod | LDPE, length 200–206 mm, stem Ø 2.1–2.3 mm |
| Suture thread | Nylon 66 with FDA-approved dye, Ø 0.20–0.30 mm |
| Duration in situ | Up to 5 years |
| Sterilisation | Gamma radiation (single use, not reusable) |
| Marking | CE 2460 · non-active implantable medical device |
| Presentation | Sterile individual packaging, sold per unit |
* Specifications according to the manufacturer’s technical data sheet. Always consult the original labelling and instructions for use before insertion, which must be performed by qualified healthcare personnel.
4. Equivalences and Cross-References
This copper IUD with silver core (380 mm², normal T format) belongs to the 380 mm² ‘silver-core copper IUD’ family, a reference type in long-acting contraception. For clinical comparison purposes:
| Manufacturer / Brand | Family / Model | Reference | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Eurogine | Novaplus® T 380 Ag Normal (Cu380+Ag) | 01010500 | Comparable by category, not interchangeable 1:1 | Same functional type: 380 mm² copper wire (99.99%) with 0.1 mm silver core, Y/T frame, normal format. Geometry and insertion specifications specific to the manufacturer. |
There is no equivalence table validated by the manufacturer that cross-references this item 1:1 with other brands; consult the technical department before use in tenders. Within the same catalogue, the compact version CU-380-AG mini (Ref. 0633024) shares material and copper surface in a reduced format for small cavities, and the copper lines without silver core (Refs. 0633019 normal and 0633020 mini) cover the same indication. Other similar brands in the sector with 380 mm² copper and silver core include the equivalent Nova T 380 and TCu 380A families; before substituting, verify measurements, material and regulatory classification in the manufacturer’s data sheet.
5. Selection tips and variants of interest
Select this normal format for patients with a standard uterine cavity seeking long-acting hormone-free contraception. If the cavity is small or the patient reports discomfort with standard-sized devices, consider the mini (Ref. 0633024) version. When a silver core is not required, the copper 380 lines (Refs. 0633019/0633020) offer an economical alternative. The professional should always measure the cavity depth with a hysterometer before choosing the size. Check the integrity of the sterile packaging and the expiry date, store it in a cool, dry place (15–30 °C) protected from light, and dispose of it after single use without re-sterilising.





Reviews
There are no reviews yet.