Description
1. Complete kit for IUD management in the clinic
The DIU-S Kit (Ref. 770269) is a ready-to-use set that brings together in a single presentation all the instruments needed to perform the complete procedure of insertion, positioning and removal of the intrauterine device (IUD). Designed for gynaecology consultations, family planning centres, reproductive health units and emergency services, it allows the professional to have each tool at the exact moment it is needed, without relying on reprocessed metal instruments.
As it is single-use material, the kit eliminates the costs and times of cleaning, disinfection and sterilisation of reusable instruments, and minimises the risk of cross-contamination between patients. Each box contains 15 units, a format designed to guarantee immediate availability in the clinic with the best cost-benefit ratio.
2. Technical explanation of the equipment and procedure
The kit covers the four essential phases of IUD placement and control:
- Measurement of the uterine cavity: the RAMISTER hysterometer, made of malleable plastic with a rounded atraumatic tip and a graduated scale for direct reading, is gently introduced through the cervical canal until it contacts the uterine fundus to assess the depth before choosing and placing the device.
- Cervical traction-fixation: the Pozzi-Palmer forceps (TIRAPALLE) grasps the cervix and corrects the flexion angle of the uterus (up to 180°), an essential manoeuvre for introducing the instruments without risk of perforation.
- Insertion and positioning: the Kelly forceps (KELLY) allows holding and guiding the IUD to its correct position in the fundus of the cavity.
- Thread trimming: the long plastic U-CUT scissors allow cutting the IUD threads to the recommended length (usually 2–3 cm outside the external cervical os) once the device is placed, facilitating its subsequent location and control. The same traction manoeuvre with the Pozzi-Palmer forceps is used for device removal.
3. Technical Specifications
Kit contents (per unit):
| Component | Function in the procedure |
|---|---|
| RAMISTER hysterometer | Measurement of the depth of the uterine cavity before insertion or removal of the IUD |
| Pozzi-Palmer forceps (TIRAPALLE) | Cervical traction-fixation and 180° alignment of the uterine flexion angle |
| Kelly forceps (KELLY) | Insertion and positioning of the IUD in the uterine cavity |
| Long plastic scissors (U-CUT) | Cutting of the IUD threads after placement |
Indicative technical data sheet of the components:
| Property | Detail |
|---|---|
| Product type | Kit for insertion, positioning and removal of IUD |
| Reference | 770269 (DIU-S KIT, standard version with long scissors) |
| Presentation | Box of 15 units |
| RAMISTER hysterometer (GINRAM®) | Curved model: scale 5–11 cm (0.5 cm), Ø 3–4 mm, length 24.5 cm · Straight model: scale 4–15 cm (1 cm), Ø 3–5 mm, length 24.5 cm |
| Pozzi-Palmer forceps | Pozzi-type cervical traction forceps |
| Kelly forceps | Forceps for IUD insertion and positioning |
| U-CUT scissors | Long plastic scissors for cutting threads |
| Use | Single-use (disposable) |
| Field of application | Gynaecology clinic, family planning, reproductive health and emergency department |
4. Equivalences and Cross-References
The DIU-S Kit is a Cahnos own-brand product, so there is no manufacturer-validated equivalence table that cross-references it 1:1 with other brands; before using it in tenders with a closed specification, we recommend consulting our technical department. For comparison purposes in the Cahnos catalogue:
| Manufacturer / Brand | Family / Model | Reference | Equivalence level | Technical differences |
|---|---|---|---|---|
| Cahnos | LU.D. KIT (DIU-S Kit without scissors) | 770268 | Direct equivalent from the same range | Same composition (hysterometer, Pozzi-Palmer and Kelly); does not include long U-CUT scissors |
| PM-CARE® | INSERT-KIT (3 pieces) | PS4190000 | Comparable by category, not interchangeable 1:1 | Composed of straight Pozzi forceps, curved Cheron forceps and distal thread scissors; without hysterometer or Kelly forceps; sterile by ethylene oxide |
| PM-CARE® | INSERT-KIT + FR14 hysterometer | PS3840000 / PS3230000 | Comparable by category, not interchangeable 1:1 | They add FR14 hysterometer (14 Fr / 4.6 mm); they use Cheron forceps instead of Kelly forceps |
| PM-CARE® | REMOV-KIT (removal) | PS3620000 | Comparable by category (removal procedure) | Aimed at IUD removal: Pozzi forceps, extraction forceps, distal scissors and hysterometer |
| Cahnos | Disposable surgical scissors U-CUT | 770114 | Equivalent component (scissors) | Individual replacement of the kit’s long scissors |
| Cahnos | Sterile long scissors 22 cm | 47299 | Comparable component (scissors) | Longer sterile alternative for thread cutting |
The components of this type of kit are also sold separately in the catalogue: disposable hysterometers PM-CARE® FR10, FR12 and FR14 (PS1251000, PS1251200, PS1251400), straight Pozzi forceps (PS3180025) and angled ones (PS3190025), Cheron forceps (PS3200025 and PS3210025) and PM-CARE® EASYCUT scissors (PS3220022 lateral and PS3580022 distal). For removal in cases of retracted threads, the REMOV IUD forceps (PS3570025) and the PM-CARE® retrieval hook (PS3830026) complete the practice.
5. Selection tips and variants of interest
- Choose this version with long U-CUT scissors (770269) if you want a closed kit that also covers thread trimming; if you already have scissors or prefer to purchase them separately, the version without scissors (770268) is the most economical option.
- For high-volume clinics, plan the order by complete boxes of 15 units and verify the integrity of each unit’s packaging before use.
- If your protocol requires sterile instruments in individual packaging, consider the single-use sterile kits PM-CARE® INSERT-KIT (PS4190000, PS3840000 or PS3230000) and REMOV-KIT (PS3620000), all sterilised with ethylene oxide.
- Complete the prior cervical preparation with disposable specula and sterile cervical dilators if your centre’s protocol requires it.
- As this is single-use material, dispose of it after a single procedure and keep it in its original packaging, in a cool, dry place, until the moment of use.