Description
Sterile Amniocentesis Needle 21G x 100 mm — Ref. 770227
The sterile 21G x 100 mm amniocentesis needle is a single-use medical device, essential in gynaecology and obstetrics departments for obtaining amniotic fluid by transabdominal puncture. Its design, with an echo-marked stylet tip and atraumatic bevel, enables a safe, precise procedure that is minimally uncomfortable for the patient, both in routine clinical practice and in prenatal diagnostic units of hospitals and private clinics.
Technical description and procedure
Amniocentesis is a prenatal diagnostic technique that involves extracting a small sample of amniotic fluid, usually between weeks 15 and 18 of gestation, for genetic study of the fetus (karyotype, diagnosis of chromosomal abnormalities) and for cytogenetic and biochemical studies. The needle is introduced transabdominally along the path previously identified by ultrasound imaging; the stylet, with its echo-marked tip, facilitates visualisation of the tip during insertion and provides rigidity to the cannula, avoiding the coring effect. Once the amniotic sac is reached, the stylet is removed and a syringe (usually 20 cc) is connected to the female luer lock connector to aspirate the fluid. The adjustable sliding stop allows the insertion depth to be fixed, and the colour coding on the stylet hub immediately identifies the gauge (21G = green).
Technical specifications
| Characteristic | Specification |
|---|---|
| Gauge | 21G (0.8 mm outer diameter) |
| Needle length | 100 mm |
| Tip type | Atraumatic sharpening; stylet with echo-marked tip (detectable by ultrasound) |
| Depth stop | Adjustable sliding stop on the cannula |
| Connection | Female luer lock connector for collection with syringe |
| Gauge coding | Green colour (international identification code) |
| Material | Stainless steel cannula with stylet |
| Sterility | Sterile, single-use; sterilised by ethylene oxide (EtO) |
| Presentation | Sterile individual packaging; box of 25 units |
| Use | Single-use (single use) |
| Indication | Transabdominal amniocentesis and prenatal diagnosis (weeks 15-18) |
| Reference | 770227 |
Equivalences and cross-references
There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders. Reference 770227 corresponds to the internal coding of Cahnos’s own range of amniocentesis needles (21G x 100 mm, green colour, box of 25 units, individual packaging). The exact 21G x 100 mm combination with echo-marked tip, adjustable stop and luer lock connector is not published with a confirmed code by other manufacturers in open sources; the homologous families on the market that must be verified spec sheet by spec sheet (gauge, length, tip type and presentation) are: GIMA (Italy, Amniocentesis Needles series, with 21G available in 120 and 150 mm), Laboratoire CCD (needles for amniocentesis and cordocentesis, 20G gauge in 100-180 mm), M.D.L. (Amnio series, Chiba 16° tip with echogenic marking), Cook Medical (Disposable EchoTip, with echogenic tip technology) and CooperSurgical/Wallace (codes 12021 and 15021 in 21G). None of these references should be considered interchangeable 1:1 without prior technical validation.
Selection tips and variants of interest
To choose the right needle, consider the gauge against the length: a 21G (0.8 mm) gauge offers less tissue trauma and good suction flow, while the length must be adapted to the thickness of the abdominal wall (the 100 mm one is ideal for patients of medium build; the 120, 150 and 180 mm ones cover thicker walls). The Cahnos range includes sterile amniocentesis needles in 20G and 21G gauges with lengths of 80, 100, 120, 150 and 180 mm, all in boxes of 25 units with individual packaging: 770212 (20Gx80), 770228 (20Gx100), 770222 (20Gx120), 770224 (20Gx150), 770201 (20Gx180), 770226 (21Gx80), 770227 (21Gx100), 770223 (21Gx120), 770202 (21Gx150) and 770229 (21Gx180). For other puncture applications in gynaecology (follicular aspiration and oocyte retrieval), see the oocyte needle range. Always verify the compatibility of the luer connector with the syringe and the suction system used, and confirm the sterility of the individual packaging before each use. For volume orders, public tenders or technical documentation needs (IFU, declaration of conformity), contact our commercial department.





Reviews