We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Sterile Amniocentesis Needle 20G x 150 mm (0.9 mm) with Echogenic Stylet, Adjustable Stop and Luer Lock | Box of 25 units | Ref. 770224

217,00 €

Sterile single-use amniocentesis needle, gauge 20G (0.9 mm) and length 150 mm, with an echogenic-tip stylet for ultrasound-guided insertion, adjustable sliding depth stop and female Luer Lock connector for collecting amniotic fluid with a syringe. Sterilised with ethylene oxide, it is supplied in individual packaging inside a box of 25 units. Reference 770224, indicated for ultrasound-guided transabdominal puncture between weeks 15 and 18 of gestation in gynaecology, obstetrics and prenatal diagnostics services.

International shipping. Import duties and taxes are payable by the recipient.

Datasheet (opens in a new tab)

Reference
770224

Description

Precision and safety in prenatal diagnosis

The sterile amniocentesis needle 20G x 150 mm (ref. 770224) is the reference instrument for transabdominal collection of amniotic fluid in gynaecology and obstetrics clinics, fetal medicine units and prenatal diagnostic centres. It is supplied in a box of 25 units with individual sterile packaging, ensuring availability, traceability and optimal hygiene conditions in each puncture. Its intermediate 150 mm length offers an excellent balance between reach and manoeuvrability, making it the most versatile size in the family, suitable for most patients with a medium body habitus.

Technical explanation of the procedure

Amniocentesis is a prenatal diagnostic technique that involves extracting a small sample of amniotic fluid, usually between weeks 15 and 18 of gestation, for genetic studies of the fetus (karyotype and detection of chromosomal abnormalities), as well as for cytogenetic and biochemical analyses. The needle is introduced transabdominally following the path previously detected by ultrasound: the stylet incorporates an echo-marked tip, detectable by ultrasound, which allows the trajectory to be visualised in real time and provides rigidity to the cannula, avoiding the coring effect. The adjustable sliding stop allows the insertion depth to be mechanically fixed, while the female Luer Lock connector ensures secure attachment of the syringe (usually 20 cc) for sample collection without leaks or disconnections. The colour coding of the stylet hub immediately identifies the gauge (yellow = 20G) and the atraumatic sharpening of the tip minimises discomfort and the risk of complications. The procedure must always be performed by qualified personnel under ultrasound guidance, with the patient properly informed.

Technical specifications

Characteristic Specification
Gauge 20G (0.9 mm outer diameter)
Needle length 150 mm
Tip type Atraumatic bevel with echo-marked stylet tip (detectable by ultrasound)
Depth stop Adjustable sliding stop on the cannula
Connection Female Luer Lock connector for syringe collection
Gauge coding Yellow colour (international colour code 20G)
Material Stainless steel cannula with stylet
Sterilisation Ethylene oxide (EtO); sterile, single-use
Presentation Box of 25 units with individual sterile packaging
Indication Transabdominal amniocentesis and prenatal diagnosis (weeks 15-18)
Classification Medical device, CE marked
Reference 770224 (SKU)

Amniocentesis needle range (box of 25 units):

Reference Gauge Length
770212 20G 80 mm
770228 20G 100 mm
770222 20G 120 mm
770224 20G 150 mm
770201 20G 180 mm
770226 21G 80 mm
770227 21G 100 mm
770223 21G 120 mm
770202 21G 150 mm
770229 21G 180 mm
770233 22G 90 mm
770232 22G 150 mm

Equivalences and cross-references

There is no equivalence table validated by the manufacturer for this reference; consult the technical department before use in tenders. Below are references from other manufacturers verified against the official catalogue or regulatory databases (GUDID/FDA and the manufacturer’s own product data sheets), comparable by category but not interchangeable 1:1 because they differ in presentation, tip type, number of units or packaging characteristics:

Manufacturer / Brand Family / Model Code / SKU Equivalence level Technical differences / Remarks
GIMA (Italy) Aghi per Amniocentesi (Amniocentesis Needles) MM29638 (29638) Comparable by category (not interchangeable 1:1) 20G x 150 mm; stylet with echo-marked tip, sliding stop and female Luer Lock connector; box of 25 units; Class IIa; verify brand and origin in tender.
Cook Medical Disposable EchoTip® Amniocentesis Needle G16289 (J-DAN-201501) Comparable by category (not interchangeable 1:1) 20G x 15 cm without side hole; EchoTip echogenic tip; Luer connector; box of 10 units; GUDID/FDA registration confirmed.
Cook Medical Disposable EchoTip® Amniocentesis Needle (with side port) G16290 (J-DAN-201502) Comparable by category (not interchangeable 1:1) 20G x 15 cm with distal side hole for suction; EchoTip echogenic tip; box of 10 units; GUDID/FDA registration confirmed.
BPB Medica (Biopsybell) GAMMA™ Aspiration Needle for soft tissue biopsy and prenatal diagnosis GM2015EC Comparable by category (not interchangeable 1:1) 20G x 15 cm; modified Chiba-type bevel, internal echogenic marker, centimetre markings, sliding stop and Luer Lock connection; box of 20 units; code confirmed in the manufacturer’s official catalogue.

Other homologous families on the market that must be verified data sheet by data sheet (gauge, length, tip type, materials and regulatory classification) before any substitution: CooperSurgical/Wallace (Wallace® Amniocentesis Needles series), M.D.L. S.r.l. (Amnio series, Chiba-type tip with echogenic marking) and Laboratoire CCD. None of these references should be considered interchangeable 1:1 without prior technical validation by the corresponding department.

Selection tips and variants of interest

To choose the right needle, weigh the gauge against the length: 20G (0.9 mm) offers good suction flow for the usual sample volume and the 150 mm length covers most patients with a medium body habitus. If a greater abdominal wall thickness is expected, the 180 mm versions (ref. 770201) may be considered; for patients with less thickness, the 80, 100 or 120 mm versions of the same range. 21G (0.8 mm) reduces the external diameter for finer punctures and 22G (0.7 mm) further minimises tissue trauma. For protocols requiring a graduated centimetre cannula, consult the variants of the same family with a cannula marked in cm. Always verify the compatibility of the Luer Lock connector with the syringe and the suction system used, confirm the integrity and expiry date of the individual sterile packaging before each use and dispose of the product after a single use as sharps biohazard waste in accordance with current regulations. For volume orders, public tenders or technical documentation needs, contact our commercial department.

Additional information

Gauge

20G (0.9 mm outer diameter)

Material

Stainless steel cannula with stylet

Mandrel

Echogenic tip detectable by ultrasound, with colour code

Connection

Female Luer Lock connector

Cap colour code

Yellow (20 G)

Sterilisation

Ethylene oxide (EtO)

Use

Single-use (disposable), not re-sterilisable

Presentation

Box of 25 units with individual sterile packaging

Classification

Medical device with CE marking

CND code

A010204

Reference

770224

Indications

Transabdominal amniocentesis and prenatal diagnosis (weeks 15-18)

Compatibility

Latex-free and DEHP-free

Tip type

Atraumatic sharp with echo-marked stylet tip

Depth stop

Adjustable sliding stop on the cannula

Colour coding

Yellow (international colour code 20G)

Longitud

15 cm

Reviews

There are no reviews yet.

Be the first to review “Sterile Amniocentesis Needle 20G x 150 mm (0.9 mm) with Echogenic Stylet, Adjustable Stop and Luer Lock | Box of 25 units | Ref. 770224”

Your email address will not be published. Required fields are marked *