We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Electrode holder reducers (chucks) from Ø 4 mm to Ø 2.4 / 1.6 / 0.8 mm for HF electrosurgery — REGER

Price on request

Electrode holder reducers (chucks) from REGER Medizintechnik to adapt the Ø 4 mm housing of the handle to electrodes with a shaft of Ø 2.4 mm, Ø 1.6 mm or Ø 0.8 mm. Easy and quick fixing, reusable and autoclavable construction at 134 °C, with a length of 4.5 cm and a maximum voltage of 4.3 kVp. References 293-5, 293-6 and 293-8, unit per pack. Ideal for expanding the compatibility of your high-frequency (HF) surgery system and making use of smaller-diameter electrodes. Sale on quotation; consult your technical-commercial advisor at Cahnos.

International shipping. Import duties and taxes are payable by the recipient.

Reference
RGR-HF-REDUCTOR

Description

1. Introduction

The electrode holder reducers (chucks) from REGER Medizintechnik GmbH (Germany) are the ideal complement to get the most out of your high-frequency (HF) electrosurgery system. They allow the standard Ø 4 mm housing of your electrode holder handle to be adapted to electrodes with a smaller-diameter shaft (Ø 2.4 mm, Ø 1.6 mm or Ø 0.8 mm), without having to change the handle or the generator. Their easy and quick coupling, their reusable nature and their autoclave sterilisation at 134 °C make them a cost-effective and versatile solution for operating theatres, minor surgery clinics, dermatology and gynaecology.

2. Technical explanation

In monopolar electrosurgery, the high-frequency current generated by the unit reaches the active electrode through the electrode holder handle. The shaft diameters of the electrodes can vary depending on the manufacturer and the indication, so the chuck acts as a reduction and adaptation element: it fits into the Ø 4 mm socket of the handle and securely fixes the shaft of the smaller-diameter electrode (Ø 2.4 mm, Ø 1.6 mm or Ø 0.8 mm). The result is a stable, quick and backlash-free coupling that maintains the orientation of the tip during the surgical procedure. Being reusable and autoclavable (134 °C), it allows the accessory to be re-sterilised after each use and extends the service life of the system.

3. Technical Specifications

Characteristic Value
Brand / Manufacturer REGER — REGER Medizintechnik GmbH (Germany)
Product type Electrode holder reducer (chuck) for HF electrosurgery
Electrode holder diameter Ø 4 mm
Length 4.5 cm
Maximum voltage (Umax) 4.3 kVp
Use Reusable
Sterilisation Autoclavable (134 °C)
Presentation Unit per pack

Manufacturer’s specifications

Characteristic Value
Electrode holder diameter Ø 4 mm
Length 4.5 cm
Maximum voltage (Umax) 4.3 kVp

Available references

REGER reference Electrode diameter Units per pack
293-5 Ø 2.4 mm 1
293-6 Ø 1.6 mm 1
293-8 Ø 0.8 mm 1

4. Equivalences and Cross-References

References 293-5, 293-6 and 293-8 are the original catalogue designation from REGER Medizintechnik for the electrode holder reducers (Spannzangen); in Cahnos they are marketed under the RGR-HF-REDUCTOR family (base SKU), with the RGR- prefix per reference (RGR-293-5, RGR-293-6 and RGR-293-8). There is no 1:1 equivalence table validated by the manufacturer with other brands; reducing chucks from other manufacturers that adapt from Ø 4 mm to 2.38 mm (3/32″) shafts may be comparable by category, but must be validated field by field (housing diameter, shaft diameter and fixing system) before any substitution. Consult our technical department if you need to verify compatibility with your electrode holder handle.

5. Selection tips and variants of interest

Select the reducer according to the shaft diameter of the electrodes used in your HF electrosurgery system: reference 293-5 is the option for electrodes with a Ø 2.4 mm shaft (the standard range from REGER), 293-6 for a Ø 1.6 mm shaft and 293-8 for a Ø 0.8 mm shaft. Always verify that your electrode holder handle has a Ø 4 mm housing. Within the same REGER HF electrosurgery system, you will find in Cahnos the reusable electrode holder handles without buttons (RGR-MANGO-SIN-BOTONES) and the compatible active electrode families: wire loop and ribbon (RGR-HF-ASA-24 and RGR-HF-ASA-4), needle and tungsten (RGR-HF-AGUJA-24 and RGR-HF-AGUJA-4), blade, spatula and lancet (RGR-HF-HOJA-24 and RGR-HF-HOJA-4), ball (RGR-HF-BOLA-24) and conization (RGR-HF-CONIZ-24 and RGR-HF-CONIZ-4). After each use, subject the reducer to autoclave sterilisation at 134 °C and periodically inspect the condition of the housing and the electrode fit. For B2B conditions, tenders or volume orders, consult your technical-commercial advisor at Cahnos.

Additional information

Diámetro del electrodo

Ø 2,4 mm, Ø 1,6 mm, Ø 0,8 mm

Units per pack

1

REGER reference

293-5, 293-6, 293-8

Manufacturer

REGER Medizintechnik GmbH

Product type

Electrode holder reducer (chuck) for HF electrosurgery

Electrode holder diameter

Ø 4 mm

Maximum voltage umax

4.3 kVp

Sterilisation

Autoclavable (134 °C)

Presentation

1 unit per pack

References reger

293-5, 293-6, 293-8

Longitud

4.5 cm

Tipo uso

Reusable

Reviews

There are no reviews yet.

Be the first to review “Electrode holder reducers (chucks) from Ø 4 mm to Ø 2.4 / 1.6 / 0.8 mm for HF electrosurgery — REGER”

Your email address will not be published. Required fields are marked *