Description
1. Introduction
The electrode holder reducers (chucks) from REGER Medizintechnik GmbH (Germany) are the ideal complement to get the most out of your high-frequency (HF) electrosurgery system. They allow the standard Ø 4 mm housing of your electrode holder handle to be adapted to electrodes with a smaller-diameter shaft (Ø 2.4 mm, Ø 1.6 mm or Ø 0.8 mm), without having to change the handle or the generator. Their easy and quick coupling, their reusable nature and their autoclave sterilisation at 134 °C make them a cost-effective and versatile solution for operating theatres, minor surgery clinics, dermatology and gynaecology.
2. Technical explanation
In monopolar electrosurgery, the high-frequency current generated by the unit reaches the active electrode through the electrode holder handle. The shaft diameters of the electrodes can vary depending on the manufacturer and the indication, so the chuck acts as a reduction and adaptation element: it fits into the Ø 4 mm socket of the handle and securely fixes the shaft of the smaller-diameter electrode (Ø 2.4 mm, Ø 1.6 mm or Ø 0.8 mm). The result is a stable, quick and backlash-free coupling that maintains the orientation of the tip during the surgical procedure. Being reusable and autoclavable (134 °C), it allows the accessory to be re-sterilised after each use and extends the service life of the system.
3. Technical Specifications
| Characteristic | Value |
|---|---|
| Brand / Manufacturer | REGER — REGER Medizintechnik GmbH (Germany) |
| Product type | Electrode holder reducer (chuck) for HF electrosurgery |
| Electrode holder diameter | Ø 4 mm |
| Length | 4.5 cm |
| Maximum voltage (Umax) | 4.3 kVp |
| Use | Reusable |
| Sterilisation | Autoclavable (134 °C) |
| Presentation | Unit per pack |
Manufacturer’s specifications
| Characteristic | Value |
|---|---|
| Electrode holder diameter | Ø 4 mm |
| Length | 4.5 cm |
| Maximum voltage (Umax) | 4.3 kVp |
Available references
| REGER reference | Electrode diameter | Units per pack |
|---|---|---|
| 293-5 | Ø 2.4 mm | 1 |
| 293-6 | Ø 1.6 mm | 1 |
| 293-8 | Ø 0.8 mm | 1 |
4. Equivalences and Cross-References
References 293-5, 293-6 and 293-8 are the original catalogue designation from REGER Medizintechnik for the electrode holder reducers (Spannzangen); in Cahnos they are marketed under the RGR-HF-REDUCTOR family (base SKU), with the RGR- prefix per reference (RGR-293-5, RGR-293-6 and RGR-293-8). There is no 1:1 equivalence table validated by the manufacturer with other brands; reducing chucks from other manufacturers that adapt from Ø 4 mm to 2.38 mm (3/32″) shafts may be comparable by category, but must be validated field by field (housing diameter, shaft diameter and fixing system) before any substitution. Consult our technical department if you need to verify compatibility with your electrode holder handle.
5. Selection tips and variants of interest
Select the reducer according to the shaft diameter of the electrodes used in your HF electrosurgery system: reference 293-5 is the option for electrodes with a Ø 2.4 mm shaft (the standard range from REGER), 293-6 for a Ø 1.6 mm shaft and 293-8 for a Ø 0.8 mm shaft. Always verify that your electrode holder handle has a Ø 4 mm housing. Within the same REGER HF electrosurgery system, you will find in Cahnos the reusable electrode holder handles without buttons (RGR-MANGO-SIN-BOTONES) and the compatible active electrode families: wire loop and ribbon (RGR-HF-ASA-24 and RGR-HF-ASA-4), needle and tungsten (RGR-HF-AGUJA-24 and RGR-HF-AGUJA-4), blade, spatula and lancet (RGR-HF-HOJA-24 and RGR-HF-HOJA-4), ball (RGR-HF-BOLA-24) and conization (RGR-HF-CONIZ-24 and RGR-HF-CONIZ-4). After each use, subject the reducer to autoclave sterilisation at 134 °C and periodically inspect the condition of the housing and the electrode fit. For B2B conditions, tenders or volume orders, consult your technical-commercial advisor at Cahnos.