We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Disposable electrosurgical pencil with foot pedal control — 320 cm cable, 2.38 mm shaft, 3.2 mm connector and F4067 ball (Ref. F4390/PL). Box of 50 units.

159,96 €

Disposable single-use electrosurgical pencil with foot pedal control, ready for monopolar cutting and coagulation surgery. Includes F4067 ball (Ø 4 mm) mounted on a 2.38 mm shaft, 320 cm cable and 3.2 mm monopolar connector. Supplied in a box of 50 sterile units (Ref. F4390/PL), ideal for equipping operating theatres, private clinics and institutional replenishment with optimised cost per procedure.

International shipping. Import duties and taxes are payable by the recipient.

Reference
F4390/PL

Description

1. Product Presentation

The foot pedal-controlled electrosurgical pencil Ref. F4390/PL is the consumable your operating theatre team needs for open surgery: clean cutting, reliable haemostasis and the peace of mind of a sterile single-use product, ready to use in every procedure. Foot pedal activation frees the surgeon’s hands, allowing full control of cutting and coagulation with the foot, without releasing the instrument or diverting attention from the field.

Supplied in a box of 50 sterile units with factory-mounted F4067 ball, it is the ideal choice for hospitals, private clinics and purchasing centres seeking the best balance between cost per procedure, safety, consistent supply and performance in every intervention.

2. Technical explanation of the equipment and procedure

The foot pedal-controlled electrosurgical pencil is a monopolar electrosurgery pencil: the radiofrequency current generated by the generator (ESU) travels through the cable to the active electrode (the F4067 ball) and concentrates at the point of contact with the tissue, producing the desired surgical effect — cutting, coagulation or mixed — and returning via the patient’s neutral (dispersive) plate.

  • Foot pedal activation: control of cutting and coagulation with the foot, without manual buttons on the handle, ideal for prolonged manoeuvres and precise dissections.
  • F4067 ball: Ø 4 mm ball electrode in stainless steel, suitable for contact coagulation and controlled fulguration on delicate surfaces.
  • 2.38 mm shaft: standard diameter for pencil electrodes (3/32″), compatible with the housing of most pencils in the sector.
  • 320 cm cable: wide reach over the surgical field without tension, designed to distribute across the table and move the pencil freely.
  • 3.2 mm connector: standard monopolar plug for quick and secure connection to the generator socket (adapters F4830–F4838 for other standards).
  • Sterile single-use: eliminates the risk of cross-contamination and the costs of cleaning and re-sterilisation.

3. Technical Specifications

Characteristic Specification
Product type Disposable electrosurgery pencil (electrosurgical unit), single-use
System Monopolar, cut and coagulation
Activation Foot pedal control (hands-free)
Electrode F4067 stainless steel ball, ball Ø 4 mm
Shaft diameter 2.38 mm (3/32″)
Cable length 320 cm
Connector 3.2 mm monopolar plug
Sterility Sterile, single-use disposable
Presentation Box of 50 units
Reference F4390/PL

Compatibility: the 3.2 mm connector fits the standard monopolar socket of most electrosurgical generators on the market. For generators with a different connection standard (Valleylab, 4 mm, Erbe), please refer to the variants with specific connector (e.g. F4390/4M) or the reusable adapters from the F4830–F4838 range.

4. Equivalences and Cross-References

The reference F4390/PL is a proprietary distribution code of Cahnos. There is no equivalence table validated by the manufacturer covering this reference; the following rows are functional comparisons verified against official catalogues and regulatory databases (GUDID/FDA), not 1:1 equivalences.

Manufacturer / Brand Family / Model Code / SKU Equivalence Level Technical Differences / Remarks
Bovie (Aspen Surgical) Electrosurgical Foot Control Pencil (disposable monopolar pencil, box of 50 units) ESP7 Comparable by category (not interchangeable 1:1) Same product type: disposable foot pedal-controlled pencil, monopolar, single-use and supplied in a box of 50 units. Differs: the mounted electrode (standard steel blade vs. F4067 Ø 4 mm ball), cable length and connector standard (3-pin Valleylab type vs. 3.2 mm plug). Code and attributes verified in GUDID/FDA (model ESP7, Aspen Surgical Products, Inc.).
Medline (Medline Industries) Pencil, Cautery, Foot Switch, PTFE Blade ESFS3002 Comparable by category (not interchangeable 1:1) Disposable cauterisation pencil with foot switch and mounted electrode. Differs: PTFE-coated blade electrode vs. F4067 stainless steel ball, in addition to cable length and connector. Code and attributes verified in GUDID/FDA (model ESFS3002, Medline Industries, Inc.).

There is no equivalence table validated by the manufacturer; consult with the technical department before use in tenders. For a 1:1 substitution, always verify field by field: electrode type (Ø 4 mm ball vs. blade or needle), shaft diameter (2.38 mm / 3/32″), cable length, type of connector of the installed generator (3.2 mm vs. 4 mm or Valleylab), sterility and presentation.

5. Selection tips and variants of interest

Check your generator connector: this pencil is fitted with a 3.2 mm monopolar connector; if your ESU is of a different standard (Valleylab, 4 mm, Erbe), choose the variant with specific connector F4390/4M (4 mm plug) or use the reusable adapters from the range (F4830–F4838).

Choose the electrode geometry according to the technique: the F4067 ball is ideal for contact coagulation and fulguration; for cutting and dissection, the same family is completed with the F4046 blade (F4390), the F4048 needle (F4390/A), the F4044 ball (F4390/P), the F4050 blade (F4390/L) and the F4052 needle (F4390/AL), all with 2.38 mm shaft and 320 cm cable; the F4390/5 variant incorporates a 500 cm cable for maximum reach.

Recommended kits and accessories: F4390/H and F4390/5H (with sterile sheath F4545), F4390/75 and F4390/5-75 (with tip cleaner F7520); the F4545 sheath allows fixing the pencil to the field and the F7520 cleaner maintains electrode performance by removing eschar during the intervention. Single-use product: do not re-sterilise or reuse. For institutional volumes or tenders, consult our technical-commercial department.

Additional information

Reference

F4390/PL

Product type

Disposable electrosurgery pencil (electrosurgical unit), single-use

System

Monopolar, cut and coagulation

Activation

Foot pedal control (hands-free)

Electrode

F4067 stainless steel ball, ball Ø 4 mm

Shaft diameter

2.38 mm (3/32")

Cable length

320 cm

Connector

3.2 mm monopolar plug

Sterility

Sterile, single-use disposable

Presentation

Box of 50 units

Compatibility

Electrosurgical generators with 3.2 mm monopolar socket; adapters F4830–F4838 for other standards

Reviews

There are no reviews yet.

Be the first to review “Disposable electrosurgical pencil with foot pedal control — 320 cm cable, 2.38 mm shaft, 3.2 mm connector and F4067 ball (Ref. F4390/PL). Box of 50 units.”

Your email address will not be published. Required fields are marked *