We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Disposable electrosurgery pencil with dual button, without electrode, 3-pin Valleylab connector and 320 cm cable — FIAB Ref. F4797/WB · Box of 50 units

Price on request

Disposable electrosurgical pencil FIAB Ref. F4797/WB, sterile and single-use, with manual dual-button control (cut and coagulation), connector type 3-pin Valleylab and 320 cm cable. Supplied without electrode: it accepts virtually all interchangeable 2.38 mm (3/32″) shaft tips on the market, allowing the tip to be customised per procedure in open surgery and minor surgery. Manufactured by FIAB SpA (Italy), it is compatible with most electrosurgical generators (ESU). Presentation in a box of 50 units with individual sterile packaging, ideal for operating theatre supplies, clinics and institutional purchases. Sale on quotation; request conditions and availability for your centre.

International shipping. Import duties and taxes are payable by the recipient.

Reference
FIAB-F4797-WB
Brand
FIAB

Description

1. Product Presentation

The disposable electrosurgery pencil FIAB Ref. F4797/WB is the turnkey solution for surgical services that need a reliable, sterile, ready-to-use monopolar electrosurgical unit for each procedure. This single-use handpiece features manual dual-button control, a 3-pin Valleylab-type connector and a 320 cm cable, and is supplied without electrode: the hospital selects the 2.38 mm shaft tip that best suits the technique for each procedure, optimising the cost per intervention. Its presentation in a box of 50 units with individual sterile packaging facilitates stock rotation and consumption control in hospitals, clinics and purchasing centres.

2. Technical explanation of the equipment and procedure

The electrosurgical unit acts as the active electrode of a monopolar electrosurgery system: the pencil connects to the generator (ESU) via the tripolar 3-pin Valleylab-type connector and the circuit is closed through the dispersive (neutral) plate placed on the patient. The two buttons on the handle allow activation of the cut (CUT) and coagulation (COAG) functions without the need for a foot pedal, giving the surgeon ergonomic and direct control during dissection and haemostasis.

As it is supplied without an electrode, the F4797/WB works as a universal handpiece with a standard 2.38 mm (3/32″) shaft housing, compatible with virtually all interchangeable tips on the market (blade, needle, ball, coated or uncoated). The 320 cm cable provides ample freedom of movement around the operating table. Being a sterile single-use device, it eliminates the risk of cross-contamination and the costs of cleaning and re-sterilisation.

3. Technical Specifications

Available references

Characteristic Value
Brand FIAB (FIAB SpA, Vicchio, Florencia — Italia)
Reference FIAB F4797/WB
Product type Disposable electrosurgical pencil (electrosurgical unit) with push button
Control Double push button: cut (CUT) and coagulation (COAG)
Electrode Without electrode (accepts 2.38 mm / 3/32″ shaft tips)
Cable length 320 cm
Connector Valleylab (3 pins)
Sterility Sterile, single-use, individually packaged
Packaging Box of 50 individual units
Units per box (web) 50

Variants of the same family (same push-button pencil and Valleylab connector)

Reference Electrode Cable Connector
F4797 Blade F4046 320 cm Valleylab
F4797/5 Blade F4046 500 cm Valleylab
F4797/A Needle F4048 320 cm Valleylab
F4797/5A Needle F4048 500 cm Valleylab
F4797/AL F4052 needle electrode 320 cm Valleylab
F4797/L Blade F4050 320 cm Valleylab
F4797/P Sphere F4044 320 cm Valleylab
F4797/PL Sphere F4067 320 cm Valleylab
F4797/SE Blade F4046/F4050 with smoke evacuator 300 cm Valleylab (box of 10 units)

4. Equivalences and Cross-References

No official equivalence table from the manufacturer has been found in public sources to validate an exact 1:1 equivalence of this electrode-free pencil with those of other brands. The following references have been cross-checked against public documentation (official catalogues, GUDID/FDA and authorised distribution) and should be treated as comparable by category, not interchangeable 1:1 without validation from the technical department:

Manufacturer / Brand Family / Model Reference code Equivalence level
Medtronic / Valleylab (Covidien) Disposable push-button pencil (blade or needle), 10 ft cable (≈3 m) E2516 / E2516H-DA Comparable by category
Erbe Disposable 2-button electrosurgical pencil, 3 m cable 20190-107 Comparable by category
ConMed GoldLine Push Button, pre-loaded blade, 10 ft cable 130309A Comparable by category
Bovie / Aspen Surgical Disposable push-button pencil (blade or needle) ESP1 / ESP1N Comparable by category

Before any substitution, check field by field: connector type (3-pin Valleylab vs. other systems), electrode housing (2.38 mm / 3/32″), cable length, sterility, single-use and presentation.

5. Selection tips and variants of interest

The choice of electrode conditions the effect on tissue: the F4046 blade (F4797) is the versatile option for cutting; the F4048 needle (F4797/A) provides maximum precision in pinpoint incisions; and the F4044/F4067 balls (F4797/P, F4797/PL) are indicated for coagulation of large surfaces. If more reach around the operating table is needed, request the variants with a 500 cm cable (F4797/5, F4797/5A) and, for procedures with surgical smoke generation, the F4797/SE version with integrated smoke evacuator.

Always verify that your electrosurgical generator has a 3-pin Valleylab-type socket: if you use an Erbe generator, request the direct connection variant (/ERB) or the F4831, F4832 and F4833 adapters for Berchtold, Martin and Erbe generators. As complementary accessories from the electrosurgery catalogue, the sterile sheath F4545 and the sterile tip cleaner F7520 are recommended. Single-use product: do not re-sterilise or reuse. For institutional volumes or tenders, consult our technical-commercial department.

Additional information

Brand

FIAB (FIAB SpA)

Packaging

box of 50 single units

Product type

Disposable electrosurgical pencil (electrosurgical unit) with push button

Manufacturer reference

F4797/WB

Control

Double push button: cut (CUT) and coagulation (COAG)

Electrode

Without electrode (compatible with 2.38 mm / 3/32" shaft tips)

Cable length

320 cm

Connector

Valleylab (3 pins)

Sterility

Sterile, single-use, individually packaged

Presentation

Box of 50 units

Manufacturer

FIAB SpA (Vicchio, Florence, Italy)

Documentation

Reviews

There are no reviews yet.

Be the first to review “Disposable electrosurgery pencil with dual button, without electrode, 3-pin Valleylab connector and 320 cm cable — FIAB Ref. F4797/WB · Box of 50 units”

Your email address will not be published. Required fields are marked *