Split rubber REM plate 20 x 15 cm
The REM rubber electrosurgical plate is the reusable return electrode that your monopolar electrosurgical unit needs to operate with maximum safety. Its split 20 x 15 cm surface together with the REM system ensures continuous monitoring of the skin-plate contact, reducing the risk of burns at the return point. An essential component for providing a neutral plate for the company’s diathermy units. For large orders you can request a quote.
How this REM return plate works
In any procedure with a monopolar electrosurgical unit, the high-frequency current leaving the active electrode must return to the generator through a low current-density pathway. The split neutral plate collects this current in a controlled manner: its surface is divided into two sectors, allowing the generator with REM (Return Electrode Monitoring) system to continuously measure contact impedance. If the system detects partial detachment or contact failure, it interrupts energy delivery before injury can occur. As it is a reusable rubber plate without cable, it is connected to the electrosurgical unit using the plate cable Ref. 30575, which is reused between patients.
Technical specifications
| Characteristic | Value |
|---|---|
| Manufacturer | GIMA |
| Manufacturer reference | 30574 (Cahnos code: GM30574) |
| Product type | Reusable rubber electrosurgical plate (return electrode) |
| Plate type | Split (two sectors) with REM system |
| Measurements | 20 x 15 cm |
| Cable | Without cable — requires plate cable Ref. 30575 (not included) |
| Compatibility | Diathermy Ref. 30626-31, 30633-5, 30693/5/7 |
| Sales unit | 1 unit |
| Device type | Medical device (medical device) |
| Device class | II B |
| CND | Z12010980 |
| GMDN | 42551 |
| EAN | 8033003264706 |
Equivalences and cross-references
There is no official equivalence table validated by the manufacturer that cross-references reference 30574 with codes from other brands. Comparisons must be treated as functional and not as 1:1 interchangeable, so it is recommended to always validate with the technical department before any substitution and to check field by field: dimensions, plate type, REM system and generator connector.
Within the reusable plate range itself there are the flexible steel-rubber plate (Ref. 30556, 120 x 210 mm, autoclavable, with cable Ref. 30560) and the disposable split plates with solid gel (Refs. 30488 and 30493), which cover the same REM return purpose with a different usage configuration.
Selection tips and variants of interest
Check compatibility with your electrosurgical unit: this plate is indicated for the diathermy units Ref. 30626-31, 30633-5 and 30693/5/7 and requires the cable Ref. 30575, which must be purchased separately. As it is reusable, it must be cleaned after each use following the manufacturer’s instructions and visually inspected before each procedure, replacing it in the event of any crack, cut or loss of conductivity. Always apply it to dry, intact, hair-free skin, on a well-perfused muscle area away from the surgical site, and verify correct adhesion of both sectors so that REM monitoring works properly. For volume orders or special B2B conditions, consult our technical-commercial department.