Description
1. Product Presentation
Introducing the genuine FIAB connection cable (Ref. F7922) for reusable neutral plates, an essential accessory for completing the monopolar circuit of your electrosurgery with maximum reliability. With a length of 500 cm, 6.3 mm mono jack connector and integrated junction box, this cable connects the return plate to the electrosurgical unit and allows the neutral electrode to be reused in multiple procedures after cleaning.
It is the usual choice in operating theatres, minor surgery clinics, dermatology, dentistry and veterinary clinics that wish to reduce clinical waste and the recurring cost of single-use electrodes, while maintaining a safe and stable return contact.
2. Technical explanation
In monopolar electrosurgery, the high-frequency current leaves through the active electrode (pencil), passes through the patient’s tissue and must return to the generator through a low current-density path: the neutral plate or return electrode. The quality of that return path depends both on the plate and on the cable connecting it to the electrosurgical unit.
This FIAB F7922 cable guarantees that connection with a 6.3 mm mono jack connector and features a junction box, an element that facilitates the distribution and organisation of the electrical connection between the plate and the unit. When used with reusable neutral plates fitted with a 4 mm socket, the plate-cable assembly ensures a low and stable contact impedance, an essential condition for avoiding current-density concentrations that could lead to patient burns.
It is a reusable accessory: it must be cleaned after each use, visually inspected (no cuts, cracks or deterioration of the insulation) and its continuity periodically checked before each procedure.
3. Technical Specifications
Manufacturer’s specifications
| Characteristic | Value |
|---|---|
| Reference FIAB | F7922 |
| Packaging | Single unit |
| Units per box (web) | 1 |
Product features
| Characteristic | Value |
|---|---|
| Brand / Manufacturer | FIAB / FIAB SpA (Vicchio, Florence, Italy) |
| Product type | Connection cable for reusable neutral plate (return electrode) |
| Length | 500 cm |
| Connector | 6.3 mm mono jack |
| Junction box | Yes (integrated) |
| Type of use | Reusable |
| Compatibility | Reusable neutral plates FIAB with 4 mm socket: F7930 (with REM system) and F7915 (without REM) |
Available references
| Reference | Description | Length |
|---|---|---|
| F7922 | Universal cable, 6.3 mm mono jack connector, with junction box | 500 cm |
4. Equivalences and Cross-References
This cable belongs to the FIAB range of connection cables for reusable neutral plates. Reference F7922 corresponds to the version with junction box; its complementary variant within the same family is F7922/WB (6.3 mm mono jack connector without junction box). Depending on the generator connector installed in your facility, it can be completed with the following references from the same commercial family:
| Reference | Description |
|---|---|
| F7922 | Universal cable, 6.3 mm mono jack connector, with junction box, 500 cm |
| F7922/WB | Cable with 6.3 mm mono jack connector, without junction box, 500 cm |
| F7922/4 | Cable with 4 mm plug, 500 cm |
| F7922/24 | Cable with double 4 mm plug, 500 cm |
| F7923 | Valleylab type cable (ESU with REM), 500 cm |
| F7923/F | Valleylab type cable (ESU without REM), 500 cm |
| F7924 | Special 6.3 mm mono jack cable for ERBE (ACC, ICC, VIO, T), 500 cm |
This cable is intended for use with the reusable silicone neutral plates from the same range: plate F7930 (200 x 150 mm, 250 cm², with REM system and 4 mm socket) and plate F7915 (without REM system, same 4 mm socket). There is no official equivalence table validated by the manufacturer for cables from other brands; before any replacement, confirm with the technical department the compatibility of the connector with your generator.
5. Selection tips and variants of interest
Check the connector on your unit: reference F7922 uses a 6.3 mm mono jack connector and incorporates a junction box. If your installation prefers a direct cable run without an intermediate box, consider reference F7922/WB.
Other connector configurations: if your unit uses a single or double 4 mm plug, consider references F7922/4 and F7922/24; if it uses a Valleylab-type connector, references F7923 (with REM) or F7923/F (without REM); for ERBE generators from the ACC, ICC, VIO and T series, reference F7924.
Compatible plate: use it with reusable FIAB plates with 4 mm socket (F7930 with REM or F7915 without REM) to ensure a stable return contact.
Maintenance: clean the cable after each use with the products indicated by the manufacturer, dry it completely and avoid sharp bends; check the insulation and continuity before each procedure and replace it at any sign of degradation.
Institutional purchasing: for operating theatre equipment or volume orders with special B2B conditions, contact our technical-commercial department.