We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Neutral shaft electrode with cable for electrosurgical unit DIATERMO 50 (Ref. 30625) and 30516 – Monopolar return plate (Ref. 30561)

44,65 €

Neutral shaft electrode with cable from the manufacturer (Ref. 30561), the dispersive return electrode designed to complete the monopolar circuit of the electrosurgical unit DIATERMO 50 (Ref. 30625) and of the unit Ref. 30516. Its shaft geometry and integrated cable ensure stable contact and safe evacuation of high-frequency current during cutting and coagulation, minimising the risk of burns at the return point. Medical device class II B, supplied as a unit and can be ordered on request for other compatible electrocautery units. For large orders you can request a quote: contact our technical-commercial team for B2B terms and volume agreements.

Sales unit: 1 unidad
Minimum order for products shipped from Italy: 150,00 € excluding VAT (can be combined)

Delivery time: 15 days

International shipping. Import duties and taxes are payable by the recipient.

Reference
GM30561

Description

Neutral shaft electrode with cable for electrosurgical unit

The neutral shaft electrode with cable (Ref. 30561) is the return accessory that completes the monopolar circuit of your electrosurgical unit, whether in the consulting room, veterinary clinic, ambulatory surgery or operating theatre. It is supplied ready to use with its cable included, which facilitates equipment preparation for each procedure. For large orders you can request a quote: contact our technical-commercial team for B2B terms, supply times and volume agreements.

How the neutral electrode works in monopolar electrosurgery

In a monopolar electrosurgery system, the generator sends high-frequency current through the active electrode (handle or pencil), which concentrates the energy at the point of contact with the tissue. The circuit is closed by means of the neutral or dispersive electrode placed on the patient, which collects the return current in a controlled and distributed manner. If the contact is not correct or the return surface is insufficient, the current density in that area increases and, with it, the risk of thermal burn to the patient. This shaft electrode, with its integrated cable, ensures a firm and stable connection with the electrosurgical unit, contributing to safe and reproducible electrosurgery.

Technical specifications

Manufacturer GIMA
Manufacturer reference 30561
Sales unit 1 pc (1 unit)
Device type Medical device (Medical device)
Device class II B
EAN 8033638322246

Compatibility: electrosurgical units Ref. 30625 (DIATERMO 50) and Ref. 30516. Available on request for other electrocautery units (check availability).

Equivalences and cross-references

No official equivalence table validated by the manufacturer and cross-referencing reference 30561 with 1:1 codes from other brands has been found in reliable sources; any substitution with neutral electrodes from other manufacturers must be validated field by field (electrode type, active surface, connector and compatibility with the generator’s monitoring system) with the technical department of Cahnos. Within the catalogue itself, the return family is completed with the flat neutral plate with cable 16 x 12 cm (Ref. 30564), the flexible steel neutral plate (Ref. 30555) and the cable for flexible plate (Ref. 30560). As homologous families in the sector that must be evaluated with the technical data sheet in hand before any substitution, the neutral electrodes of Aesculap (B. Braun), Medtronic-Covidien (Valleylab), Erbe, BOWA and Leonhard Lang (Skintact) are cited.

Selection tips and variants of interest

Always check that the connector of this electrode with cable is compatible with the plate socket of your electrosurgical unit and that the generator’s monitoring type accepts this type of return electrode. Always place the electrode on dry, intact, hair-free skin, in a well-perfused muscle area away from bony prominences, pacemakers and metal implants, selecting the lowest possible power. To complete the equipment of your operating theatre, Cahnos offers monopolar handles, electrodes, cables, neutral plates and pedals from the range; contact our team to configure your electrosurgery system.

Additional information

Manufacturer reference

30561

Device type

Medical device (medical device)

Sales unit

1 pc (1 unit)

EAN

8033638322246

Electrode type

Neutral shaft electrode with cable

Compatibility

Electrosurgical units ref. 30625 (DIATERMO 50) and Ref. 30516; other electrocautery units on request

Presentacion

Unit

Tipo dispositivo

Medical device

Clase sanitaria

II b

Documentation

📄 DatasheetEnglish PDF
📜 Declaration of conformityEnglish PDF
📜 CE certificateMultilingüe PDF
📜 ISO 9001 / 13485 certificatesMultilingüe PDF

Reviews

There are no reviews yet.

Be the first to review “Neutral shaft electrode with cable for electrosurgical unit DIATERMO 50 (Ref. 30625) and 30516 – Monopolar return plate (Ref. 30561)”

Your email address will not be published. Required fields are marked *