Neonatal electrosurgical foam plate 88 x 74 mm (36 cm²) with REM system, 300 cm cable and Valleylab-type connection — box of 25 units (Ref. F7820NW/V)

69,75 €

Neonatal electrosurgical foam plate single-use, with dimensions of 88 x 74 mm and active surface of 36 cm², equipped with REM return monitoring system and integrated 300 cm cable with Valleylab-type connection. The conductive hydrogel adhesive on a polyethylene foam backing ensures anatomical adaptation to the newborn, low contact impedance and uniform current distribution at the return point. Reference F7820NW/V, presentation in box of 25 units with individual packaging; non-sterile, single-use and latex-free product, indicated for operating theatre and neonatology units with REM generators compatible with Valleylab plug.

International shipping. Import duties and taxes are payable by the recipient.

Datasheet (opens in a new tab)

Reference
F7820NW/V

Description

Neonatal return electrode for safe electrosurgery

The neonatal foam electrosurgical plate is the essential neutral return electrode for completing the monopolar circuit when operating on neonatal or very low birth weight patients. With a compact support of 88 x 74 mm (36 cm² of active surface), this reference offers the optimal balance between contact surface and adaptation to the newborn’s anatomy, minimising current density in the return zone.

It is presented in a box of 25 units with individual packaging: a consumption format chosen by hospitals, clinics and neonatology units that need permanent stock, batch traceability and predictable cost per procedure. Each package protects the conductive hydrogel until the moment of use.

How the return plate with REM system works

In any intervention with a monopolar electrosurgical unit, the high-frequency current that leaves the active electrode (handle or pencil) passes through the tissue and must return to the generator via a low current density path. The neutral plate collects this current in a controlled manner: if the contact is not correct or the surface is insufficient, the current density at the return point increases and with it the risk of thermal burn.

This plate incorporates a REM (Return Electrode Monitoring) system: its conductive surface is divided into two sectors, allowing the electrosurgical generator to continuously measure the skin-plate contact impedance. If the system detects partial detachment, gel dryness or a failure in contact quality, it interrupts energy emission before injury occurs. The polyethylene foam support with conductive hydrogel adhesive favours adaptation to the neonate’s contour and uniform contact, while the 300 cm cable with Valleylab-type connection offers direct compatibility with REM generators that use this plug and freedom of plate placement during the intervention.

Technical specifications

Reference / SKU F7820NW/V
Product type Disposable return plate (electrode) for monopolar electrosurgery
Population Neonatal
Measurements 88 x 74 mm
Active surface 36 cm²
Support Polyethylene foam
Conductive adhesive Hydrogel
Safety system REM (Return Electrode Monitoring), plate divided into two sections
Cable length 300 cm
Connection Valleylab type (REM)
Use Single-use (disposable, non-sterile)
Latex-free Yes
Presentation Box of 25 units with individual packaging
Regulatory classification CE-marked medical device, class IIb (family F7820)

Neonatal range of the foam family (88 x 74 mm): all references share the same foam support and hydrogel adhesive; the difference lies in the REM system and the connection mode to the generator.

Reference Measurements Active surface REM Cable Connection
F7805N 88 x 74 mm 36 cm² No No TAB (tabs)
F7820N 88 x 74 mm 36 cm² Yes No TAB (tabs)
F7820NW/V 88 x 74 mm 36 cm² Yes 300 cm Valleylab

Equivalences and cross-references

There is no official equivalence table validated by the manufacturer that cross-references this reference with codes from other brands. The comparisons shown below are functional comparisons verified against documentation from each cited manufacturer and should not be treated as 1:1 interchangeable without validation from the technical department.

Manufacturer / Brand Family / Model Reference Code / SKU Equivalence Level Technical Differences / Remarks
Medtronic / Covidien (Valleylab) Valleylab™ REM PolyHesive™ II Infant Patient Return Electrode (with cable) E7510-25 (UDI 10884524001043) Comparable by category (not interchangeable 1:1) Same REM return function with Valleylab-type connector, integrated cable and use in paediatric patients from 2.7 to 13.6 kg. They differ in the substrate (PolyHesive™ II hydrogel versus foam support), exact measurements and cable length (2.7 m / 9 ft versus 300 cm). Code and attributes verified in GUDID/FDA and on the manufacturer’s official website.
Nissha Medical Technologies (Graphic Controls) SWAROPLATE Split Diathermy Pad Infant/Pediatric REM 1253H (PMF 6000834N) Comparable by category (not interchangeable 1:1) Very similar option: split plate with REM control, polyethylene foam support (PE foam), conductive hydrogel adhesive and Valleylab-REM connector with cable, for infants and premature babies < 5 kg. Differences: measurements (165 x 74 mm versus 88 x 74 mm) and active surface (≈66 cm² versus 36 cm²). Code and attributes verified in the manufacturer’s official catalogue.
BOENMED Grounding Pad with Cable, Bipolar, Valleylab REM Plug, Infant 512412 Comparable by category (not interchangeable 1:1) Infant return plate with foam support, conductive hydrogel and REM plug type Valleylab with cable. The measurements and active surface differ (not officially published) and the presentation (box of 500 units versus box of 25 units). Code and attributes verified in the manufacturer’s official catalogue.

The cited references have been cross-checked against regulatory databases (GUDID/FDA), official catalogues and technical data sheets of each cited manufacturer. Although they coincide in function (return with REM control, Valleylab-type connector, paediatric/neonatal population and single-use), they differ in substrate, exact measurements, active surface and cable length, so they are not 1:1 interchangeable. There is no equivalence table validated by the manufacturer; consult the technical department before use in tendering.

Other homologous families in the sector that must be evaluated with the technical data sheet in hand before any substitution: split paediatric/neonatal neutral plates from B. Braun / Aesculap, disposable REM bipartite plates from GIMA and infant neutral electrodes from manufacturers present on technical portals such as EMED, Promed or Upspring Medical. In all cases, check field by field: exact dimensions, active surface in cm², support and type of hydrogel, REM system, physical connector and compatibility with the installed generator.

Selection tips and variants of interest

Check your generator’s plug: this reference F7820NW/V is for equipment with a Valleylab-type return socket with REM control. If your electrosurgical unit uses a bipolar jack of Ø6.3 mm (Erbe-type standard), consider the adult reference F7820W/6.3 or consult the technical department for the appropriate neonatal variant.

  • Cableless version with tab connection (TAB) in the same neonatal population: F7820N (88 x 74 mm, 36 cm², with REM), indicated when the generator has its own plate cable or when working with cables type F7903 (Valleylab with REM).
  • If your generator does not have REM control, the homologous option in the same size with TAB connection is the F7805N (88 x 74 mm, 36 cm², without REM).
  • For other populations: paediatric F7820PW/V (148 x 90 mm, 72 cm², REM, 300 cm, Valleylab) and adult F7820W/V (202 x 101 mm, 118 cm², REM, 300 cm, Valleylab).
  • To extend compatibility with other generators, the adapters F4828 (from Valleylab-type connection to 4 mm plug) and F4829 (to 6.3 mm plug) can be used, as well as the connection cable F7903 (Valleylab type with REM).

Always apply to dry, intact, hair-free skin, on a well-perfused muscle area and away from prominent bony areas. In neonatal patients, especially check the available contact surface and do not cut or reuse the plate. Check the integrity of the individual packaging and the expiry date before each use: it is a single-use and non-sterile product.

Additional information

Material

Foam support (PE foam) with conductive hydrogel adhesive

Measurements

88 x 74 mm

Active surface

36 cm²

Safety system

REM (Return Electrode Monitoring), plate divided into two sections

Connection

Valleylab type (REM)

Cable length

300 cm

Use

Single-use (disposable, non-sterile)

Presentation

Box of 25 units with individual packaging

Compatibility

Electrosurgical generators with Valleylab-type connector and REM control

Regulatory classification

CE-marked medical device, class IIb (family F7820)

Reference

F7820NW/V

Product type

Disposable return plate (electrode) for monopolar electrosurgery

Tipo paciente

Neonatal

Latex

Latex-free

Reviews

There are no reviews yet.

Be the first to review “Neonatal electrosurgical foam plate 88 x 74 mm (36 cm²) with REM system, 300 cm cable and Valleylab-type connection — box of 25 units (Ref. F7820NW/V)”