We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Adult foam electrosurgical plate, 202 x 101 mm (132 cm²), without REM system, without cable and with TAB (tab) connection — box of 25 units (Ref. F7805)

23,65 €

Foam electrosurgical plate (neutral return electrode) for adults, with a 202 x 101 mm backing and an active surface of 132 cm². Model without REM system and without cable, with tab connection (TAB): use it with the reusable plate cable of your electrosurgical unit (F7902 universal 6.3 mm, F7903 Valleylab type or F7904 for Erbe) and reduce the cost per procedure. The hydrogel adhesive on polyethylene foam ensures anatomical adaptation, low contact impedance and uniform distribution of the return current. Presentation in a box of 25 units with individual packaging; single-use, non-sterile and latex-free product. Ref. F7805.

International shipping. Import duties and taxes are payable by the recipient.

Reference
F7805

Description

Foam return electrode for monopolar electrosurgery in adult patients

The foam electrosurgical plate Ref. F7805 is the essential neutral return electrode for completing the monopolar circuit of any high-frequency electrosurgery unit. With a backing of 202 x 101 mm and 132 cm² of active surface, it provides the contact area required by the adult patient, minimising current density in the return zone and, with it, the risk of thermal burns. It is supplied in a box of 25 units with individual packaging, the consumption format chosen by hospitals, clinics and ambulatory surgery centres that need permanent stock and predictable cost per procedure.

How the return plate works and why it is important

In any monopolar electrosurgery procedure, the high-frequency current leaves the active electrode (handle or pencil), passes through the patient’s tissue and must return to the generator via a low current density path. The neutral plate collects this current in a controlled manner: if contact is not correct or the surface is insufficient, the current density at the return point increases and with it the risk of burns to the patient.

This plate is constructed with a polyethylene foam backing (PE foam) and conductive hydrogel adhesive, which favours adaptation to the body contour of the adult patient and uniform contact on the skin. It belongs to the series without REM system: it does not activate the return monitoring control (REM) of the generator, so it must be used with conventional equipment without the requirement of a split plate, always selecting the lowest possible energy level. As it is a cable-free plate with TAB (tab) connection, the professional must use a reusable plate cable (F7902 universal 6.3 mm, F7903 Valleylab type or F7904 for Erbe), a configuration that reduces the cost per procedure and facilitates warehouse management.

Technical specifications

Reference / SKU F7805
Product type Disposable return plate (electrode) for monopolar electrosurgery
Dimensions 202 x 101 mm
Active surface 132 cm²
Support Polyethylene foam
Conductive adhesive Hydrogel
System Without REM system (does not activate the generator’s REM control)
Power supply Without cable
Connection TAB (tab)
Population Adult
Use Single-use (disposable, non-sterile)
Latex-free Yes
Presentation Box of 25 units with individual packaging
Regulatory classification Medical device with CE marking

Adult range of the foam family without REM (same base of 132 cm²): the three references share the same hydrogel and foam base and the same active surface; the difference lies exclusively in the connection system to the generator.

Reference Dimensions Support Active surface REM Cable Connection
F7805 (this product) 202 x 101 mm Foam 132 cm² No No TAB (tab)
F7805W/V 202 x 101 mm Foam 132 cm² No 300 cm Valleylab type
F7805W6.3 202 x 101 mm Foam 132 cm² No 300 cm Bipolar Ø 6.3 mm

Equivalences and cross-references

There is no official equivalence table validated by the manufacturer that cross-references this reference with codes from other brands. The comparisons shown below are functional comparisons verified against public documentation from each cited manufacturer (GUDID/FDA regulatory databases, official catalogues and technical data sheets) and should not be treated as 1:1 interchangeable without validation from the technical department.

Manufacturer / Brand Family / Model Reference Code / SKU Equivalence Level Technical Differences / Remarks
Leonhard Lang (Skintact® Cool Contact) Universal Neutral Electrode, unsplit, for adult, without cable RS05 Comparable by category (not interchangeable 1:1) Structurally very similar option: non-split plate (without REM) for adult (> 15 kg), flexible foam backing, low-impedance hydrogel and tab connection without pre-wired cable, compatible with reusable cables. The conductive surface differs (134 cm² vs 132 cm²), the geometry (bottle shape with c-LINE technology) and the presentation (pack of 1 or 5 units, box of 50 vs box of 25). Code and attributes verified in the manufacturer’s official technical documentation and in authorised distribution catalogues.
Medtronic / Covidien (Valleylab) Valleylab™ REM PolyHesive™ II Adult Patient Return Electrode (with cable) E7507 (UDI 10884524000077) Comparable by category (not interchangeable 1:1) Same return function for adult, single-use and for one use only; indicated for patients over 13.6 kg. The substrate differs (PolyHesive™ II hydrogel adhesive vs polyethylene foam backing), the configuration (split REM plate vs non-REM plate) and the connection (integrated 2.7 m cable with Valleylab type plug vs cable-free TAB). Code and attributes verified in GUDID/FDA and on the manufacturer’s official website.
Nissha Medical Technologies (ex Graphic Controls) SWAROPLATE Split Diathermy Pad, Adult, REM connector 1251H / 6000811N Comparable by category (not interchangeable 1:1) Return plate for adult with polyethylene foam backing (PE foam) and conductive hydrogel adhesive. The backing size differs (200 x 106 mm vs 202 x 101 mm), the adhesive surface (144 cm² vs 132 cm² active surface) and the configuration (split plate with REM control and Valleylab-REM connector with cable vs non-REM plate and cable-free TAB connection). Code and attributes verified in GUDID/FDA (catalogue 6000811N, model 1251H).

The cited references have been cross-checked against regulatory databases (GUDID/FDA), official catalogues and technical data sheets of each cited manufacturer. Although they coincide in function (single-use return electrode for adult), they differ in substrate, exact measurements, active surface, REM system or connection system, so they are not 1:1 interchangeable. Other homologous families in the sector that should be evaluated with the technical data sheet in hand before any substitution: adult neutral plates from B. Braun / Aesculap (Patient Plates), PolyHesive series from Medtronic-Covidien / Valleylab, SWAROPLATE from Nissha Medical Technologies, Skintact from Leonhard Lang, disposable plates from GIMA, BOWA Medical return plates, EMED neutral electrodes and Taktvoll Patient Return Electrode. In all cases, each field must be checked: exact dimensions, active surface in cm², backing and type of hydrogel, REM system, physical connector (TAB tab) and compatibility with the installed electrosurgical generator. Do not assume equivalence based only on the generic product name.

There is no equivalence table validated by the manufacturer; consult the technical department before using in tender.

Selection tips and variants of interest

Check your generator connection: the cable-free F7805 plate with TAB connection requires a reusable plate cable (F7902 universal 6.3 mm, F7903 Valleylab type or F7904 for Erbe). Choose the cable according to the plug of your electrosurgical unit; the cable is reused between patients, which reduces the cost per procedure.

Do you prefer a plate with integrated cable? The models F7805W/V (Valleylab type connection) and F7805W6.3 (bipolar connection Ø 6.3 mm) offer the same plate body (202 x 101 mm, 132 cm², without REM) with a 300 cm cable, for direct use without an additional cable.

Does your generator have REM control? The homologous alternative in the same size with REM system and TAB connection is the F7820 (202 x 101 mm, 118 cm², with REM, without cable); there are also cable versions F7820W/V and F7820W/6.3.

Other patient groups in the same family without REM: paediatric F7805P (148 x 90 mm, 78 cm², TAB), paediatric with cable F7805PW/V and neonatal F7805N (88 x 74 mm, 36 cm², TAB).

Extended compatibility: adapters F4828 (from Valleylab-type connection to 4 mm plug) and F4829 (to 6.3 mm plug) for other generators.

Application: always place on dry, intact, hair-free skin, on a well-vascularised muscle area away from bony prominences, pacemakers and metal implants. Check the integrity of the individual packaging and the expiry date before each use: it is a single-use, non-sterile product. Do not cut or reuse the plate.

Additional information

Material

Foam support (PE foam) with conductive hydrogel adhesive

Measurements

202 x 101 mm

Active surface

132 cm²

Safety system

Without REM system (does not activate the generator's REM control)

Connection

TAB (tab), without cable

Cable

Not included

Use

Single-use (disposable, non-sterile)

Presentation

Box of 25 units with individual packaging

Sterilisation

Non-sterile

Compatibility

Conventional electrosurgical generators (without split plate requirement) via reusable plate cable F7902/F7903/F7904

Regulatory classification

Medical device with CE marking

Tipo paciente

Adult

Latex

Latex-free

Reviews

There are no reviews yet.

Be the first to review “Adult foam electrosurgical plate, 202 x 101 mm (132 cm²), without REM system, without cable and with TAB (tab) connection — box of 25 units (Ref. F7805)”

Your email address will not be published. Required fields are marked *