Description
1. Product Presentation
Complete the equipment of your operating theatre, gynaecology practice or minor surgery centre with this straight loop electrode of Ø 8 mm (ref. 30343), designed for high-frequency monopolar electrosurgery. Its loop tip allows controlled cutting and coagulation on soft tissue with excellent precision, while its universal shaft of Ø 2.4 mm fits the vast majority of electrosurgical pencils and handles on the market.
As a reusable electrode autoclavable up to 30 times, it offers consistent performance at a low cost per procedure, provided the cleaning and sterilisation cycles indicated by the manufacturer are respected. It is supplied in a box of 6 units.
2. Technical explanation
In monopolar electrosurgery, the electrosurgical generator sends high-frequency current to the active electrode, which concentrates the energy at the point of contact with the tissue; the circuit is closed through the neutral (dispersive) plate placed on the patient. The loop geometry delimits the contact area and allows controlled cutting and coagulation, achieving defined margins and facilitating the excision of lesions.
The configuration of straight loop of Ø 8 mm on a straight shaft of 10 cm offers a large working surface, ideal for cervical excisions such as LEEP/LLETZ, polyp removal and resection of medium-sized lesions in gynaecology and colposcopy, as well as for minor surgery on soft tissue. Its Ø 2.4 mm shaft ensures a firm fit and stable electrical transmission throughout the procedure.
3. Technical Specifications
Electrode features
| Characteristic | Specification |
|---|---|
| Manufacturer | GIMA |
| Manufacturer reference (SKU Cahnos) | 30343 (GM30343) |
| Tip shape | Straight loop (ansa) |
| Loop diameter | Ø 8 mm |
| Shaft diameter | Ø 2.4 mm |
| Length | 10 cm |
| Sterilisation | Autoclavable up to 30 times |
| Type of use | Reusable, non-sterile |
| Presentation | Box of 6 units |
| Instructions | Multilingual: GB, FR, IT, ES, PT, DE, NL, SE, LT, PL, CZ, HU, HR, RO, GR and Arabic |
Product data
| Sales unit | box of 6 pcs |
|---|---|
| Device type | Medical device |
| Device class | II B |
| CND | Z12010980 |
| GMDN | 44683 |
| EAN | 8033638322147 |
4. Equivalences and Cross-References
Reference 30343 is the manufacturer’s original catalogue code for this straight loop electrode of Ø 8 mm and 10 cm. Within the same family, the straight loop electrode of Ø 4 mm and 10 cm corresponds to ref. 30342, and the set of 10 autoclavable electrodes of 10 cm (refs. 30340 to 30349) is marketed under ref. 30351.
No official 1:1 equivalence table cross-referencing this reference with third-party manufacturer codes has been found in reliable sources. Before comparing or substituting, verify field by field the shaft diameter (Ø 2.4 mm), the length (10 cm), the exact diameter and geometry of the tip, as well as the compatibility of the fixation system with your handle or electrosurgical unit. Consult our technical-commercial team with any compatibility questions or for tenders and bids.
5. Selection tips and variants of interest
First check the shaft diameter accepted by your electrosurgical pencil: the Ø 2.4 mm gauge of this model must fit correctly into the handle connector. Then select the tip geometry according to the technique: the loop of Ø 8 mm offers a larger excision surface, ideal for medium-sized lesions and curved cuts; if the procedure requires a finer, more conservative resection, the straight loop electrode of Ø 4 mm (ref. 30342) is available.
To immediately equip a minor surgery area, the set of 10 autoclavable electrodes (ref. 30351) brings together the most frequently used tips. If your priority is a deeper loop electrode for cervical excision, consider the loop electrode of 15 x 8 mm (ref. 30687). Always follow the recommended autoclaving cycles (up to 30 times) and the manufacturer’s cleaning instructions to preserve the electrode’s performance. For large orders you can request a quote: request your B2B offer through Cahnos.