Description
1. Product Presentation
The square loop electrode of 10 × 8 mm is a reusable electrosurgery active electrode, with a Ø 2.4 mm shaft and 13 cm length, intended for monopolar cutting and coagulation procedures and cervical excision (LEEP/LLETZ). It is supplied non-sterile for sterilisation by autoclaving at 134 °C, making it a cost-effective and sustainable solution for operating theatres, gynaecology units, colposcopy clinics and minor surgery rooms with high turnover.
2. Technical explanation of the product and procedure
In monopolar electrosurgery, the active electrode concentrates the high-frequency current emitted by the electrosurgical generator at the point of contact with the tissue; the energy returns to the unit through the neutral plate or dispersive electrode. The square geometry of the 10 × 8 mm loop (width × depth) delimits the excision area and allows tissue samples with regular, well-defined margins to be obtained, ideal for excision of the cervical transformation zone in LEEP/LLETZ techniques.
As a reusable and autoclavable instrument, the professional can reprocess it in an autoclave at 134 °C between procedures, eliminating the consumable cost per procedure compared with disposable electrodes. Its Ø 2.4 mm shaft fits most electrosurgical pencils and handles on the market with universal connection, and its 13 cm length facilitates ergonomic and precise handling during the procedure.
3. Technical Specifications
| Characteristic | Value |
|---|---|
| Loop shape | Square (loop square) |
| Loop dimensions | 10 × 8 mm (width × depth) |
| Shaft diameter | 2.4 mm |
| Stem length | 13 cm |
| Sterilisation | Autoclavable at 134 °C |
| Sterility | Non-sterile (reprocessable) |
Product data
| Manufacturer | GIMA |
|---|---|
| Sales unit | 1 pc |
| Device type | Medical device |
| Device class | IIb |
| CND | K02030101 |
| EAN | 8023279306866 |
| Manufacturer reference | 30686 |
4. Equivalences and Cross-References
There is no manufacturer-validated equivalence table cross-referencing reference 30686 with codes from other manufacturers, so it should not be treated as 1:1 interchangeable without prior technical verification. As a functional category comparison, the Cahnos reference F4631 shares the square geometry and loop dimensions (10 × 8 mm), but it is a single-use disposable tungsten electrode, whereas the present model is reusable and autoclavable. Square 10 × 8 mm formats are also found on the market in loop handle ranges from distributors such as AB Medica Group / LESSA (ref. 88.200.77), always in sterile disposable version, so shaft diameter, material and sterilisation method must be checked before any substitution or tender.
5. Selection tips and variants of interest
First check the shaft diameter accepted by your electrosurgical pencil: this electrode has a Ø 2.4 mm shaft, compatible with most universal connections on the market. Next, select the loop geometry according to the technique: the square 10 × 8 mm format offers intermediate-depth excision with regular margins, ideal for small and medium lesions of the cervical transformation zone, while deeper loops allow larger samples. Remember that, as a non-sterile product, it must be reprocessed in an autoclave at 134 °C before each use. For those who prefer to avoid reprocessing, at Cahnos we offer disposable electrodes from the same family (F4631, square loop 10 × 8 mm) in sterile single-use presentation, as well as other square geometries (F4630 10 × 4 mm and F4632 10 × 10 mm).






Reviews