Description
1. Product Presentation
The disposable electrosurgery electrode Ref. F4642 is a single-use consumable with a tip in the form of a triangular 17 × 12 mm loop, mounted on a Ø 2.38 mm shaft, designed for professionals who need precision, hygiene and optimised cost per procedure. It is marketed in a box of 24 units, an ideal format to ensure stock rotation in gynaecology clinics, colposcopy units and minor surgery operating theatres. Each unit is presented in individual sterile packaging, ready to use, eliminating cross-contamination risks and reprocessing costs.
2. Technical explanation of the product and procedure
In monopolar electrosurgery, the active electrode concentrates the high-frequency current emitted by the electrosurgical generator; the energy is applied at the point of contact with the tissue and returns through the neutral plate or dispersive electrode. The geometry of the loop delimits the contact area and allows cutting and coagulating in a controlled manner, extracting a tissue sample with defined margins.
The triangular 17 × 12 mm geometry combines good width coverage with a narrower tip, facilitating access to the cervical transformation zone and performing excisions with profiles adapted to the lesion contour. Tungsten wire offers two clinical advantages over steel: it maintains the loop shape throughout the procedure even at high powers and minimises carbonisation and lateral thermal damage, favouring the histological quality of the sample. The Ø 2.38 mm shaft corresponds to the compatibility standard of most electrosurgical pencils and handles on the market (equivalent to 3/32″).
3. Technical Specifications
| Characteristic | Value |
|---|---|
| Tip shape | Triangular loop (triangular loop) |
| Loop dimensions | 17 × 12 mm |
| Loop material | Tungsten (tungsten-coated loop family) |
| Shaft material | Stainless steel |
| Shaft diameter | 2.38 mm (3/32″) |
| Type of use | Disposable, single-use |
| Sterility | Sterile, individually packaged |
| Latex | Latex-free |
| Presentation | Box of 24 units |
| Application | Cutting and coagulation; cervical excision (LEEP/LLETZ, conisation) and soft tissue surgery |
| Compatibility | Electrosurgical pencils and generators with shaft Ø 2.38 mm (3/32″) |
| Reference | F4642 |
| SKU | 0108003 |
4. Equivalences and Cross-References
There is no equivalence table validated by the manufacturer that cross-references the F4642 reference with codes from other houses. The following references are offered as a functional category comparison verified against the cited sources (official manufacturer catalogue or authorised distributor), never as direct 1:1 interchangeable:
| Manufacturer / Brand | Family / Model | Reference Code / SKU | Equivalence Level | Technical Differences / Remarks |
|---|---|---|---|---|
| AB Medica Group – LESSA | Sterile triangular loop electrode 17 × 12 mm (24 units) | 8820081 (Henry Schein Spain: 905-8398) | Comparable by category (not interchangeable 1:1) | They match triangular geometry, dimensions 17 × 12 mm, sterile format and presentation of 24 units; verified in the Henry Schein Spain catalogue. Confirm shaft diameter and CE marking with the distributor before replacing stock. |
| Bovie (Aspen Surgical) | LLETZ Disposable Loop Electrode | ES53 | Comparable by category (not interchangeable 1:1) | Round tungsten loop 15 × 12 mm, standard shaft 3/32″ (2.3 mm), sterile, pack of 5 units; differs in geometry (round vs triangular), width (15 vs 17 mm) and units per pack. |
There is no equivalence table validated by the manufacturer that cross-references the F4642 reference with codes from other houses; consult with the technical department before using in tenders. As homologous market families for this category (disposable tungsten loops for cervical excision) the following ranges are identified: CooperSurgical LEEP, MegaDyne LLETZ Loops (Ethicon group), UtahLoop by Utah Medical Products, MedGyn Disposable Electrodes, Bovie (Aspen Surgical), DTR Medical and Medline. Before using any of these references as stock replacement, check shaft diameter, exact tip geometry (triangular, round, square or trapezoidal), sterility and units per pack against the manufacturer’s technical data sheet.
5. Selection tips and variants of interest
First verify the shaft diameter accepted by your electrosurgical pencil: the standard Ø 2.38 mm (3/32″) is the most common; there are Ø 4 mm versions that require an adapter. Then select the loop geometry according to the technique: the 17 × 12 mm triangular loop offers an intermediate profile, with good width coverage and a narrower tip, indicated for excisions of the cervical transformation zone in colposcopy; round loops facilitate curved cuts, square loops provide samples with regular margins, and trapezoidal loops allow wide, shallow excisions.
In this same family, interesting variants are offered in a box of 24 units: F4630 (square loop 10 × 4 mm), F4631 (square loop 10 × 8 mm), F4632 (square loop 10 × 10 mm), F4640 (trapezoidal 30 × 5 mm) and F4641 (inverted curve 23 × 13 mm), all on a Ø 2.38 mm shaft platform and tungsten loop. For hospital purchases and tender processes, check the CE marking under Regulation (EU) 2017/745 (MDR) and request special volume conditions from our sales department.





Reviews