Description
1. Product Presentation
The disposable electrosurgery electrode Ref. F4622 is a single-use consumable with a round loop tip of 10 × 7 mm, made of tungsten wire and mounted on a universal stainless steel shaft of Ø 2.38 mm (3/32″). It is marketed in a box of 24 individually packaged units, a format designed to ensure stock rotation and consumption planning in operating theatres, gynaecology units, colposcopy clinics and minor surgery rooms. It is the ideal reference for the professional seeking a reliable, sterile replacement electrode with optimised cost per procedure, ready for immediate use in cervical excision techniques such as LEEP/LLETZ.
2. Technical explanation of the product and procedure
In monopolar electrosurgery, the active electrode concentrates the high-frequency current emitted by the electrosurgical generator; the energy is applied at the point of contact with the tissue and returns through the neutral plate or dispersive electrode. The round geometry of the loop delimits the contact area and allows controlled cutting and coagulation, extracting a tissue sample with defined margins and facilitating curved cuts over the cervical transformation zone in LEEP (loop electrosurgical excision procedure) and LLETZ (large loop excision of the transformation zone) techniques.
Tungsten wire offers two clinical advantages over steel: it maintains the shape of the loop throughout the procedure even at high powers and minimises carbonisation and lateral thermal damage, favouring the histological quality of the sample for histopathological analysis. The 10 × 7 mm profile (width 10 mm, depth 7 mm) offers a medium-depth excision, indicated for small to medium-sized lesions in the cervical transformation zone. The Ø 2.38 mm shaft corresponds to the universal compatibility standard of most electrosurgical pencils and handles on the market (equivalent to 3/32″). Being a single-use product, the risk of cross-contamination and reprocessing costs are eliminated, guaranteeing traceability and sterility in each procedure.
3. Technical Specifications
| Characteristic | Value |
|---|---|
| Shape | Round loop (round loop) |
| Loop dimensions | 10 × 7 mm (width × depth) |
| Loop material | Tungsten (wire) |
| Shaft material | AISI stainless steel |
| Shaft diameter | 2.38 mm (3/32″) |
| Total length | 135 mm ± 3% |
| Insulation / protection | Anti-shock protector made of HIPS plastic, latex-free; anti-rotation hexagonal lock |
| Type of use | Disposable, single-use |
| Sterilisation | Ethylene oxide (EO); individual sterile heat-sealed packaging |
| Latex | Latex-free |
| Presentation | Box of 24 individually packaged units |
| Application | Cutting and coagulation; cervical excision (LEEP/LLETZ, conisation) and soft tissue surgery |
| Compatibility | Electrosurgical pencils and generators with universal connection of Ø 2.38 mm (3/32″) |
| Regulatory classification | Medical device class IIb, in accordance with Directive 93/42/EEC and amendments |
| Expiry | 4 years from production date if stored correctly |
| Storage | Temperature 0 to +50 °C; relative humidity 20–80% |
| Reference | F4622 |
4. Equivalences and Cross-References
There is no equivalence table validated by the manufacturer that cross-references the F4622 reference with codes from other brands. The following references are offered as a functional category comparison verified against the cited sources (official manufacturer catalogue or GUDID regulatory database), never as direct 1:1 interchangeable items:
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| CooperSurgical (LEEP®) | LEEP Radius Electrode 1.0 × 0.7 cm | R1007 | Comparable by category (not interchangeable 1:1) | Medium-radius round loop 10 × 7 mm in tungsten wire, 12 cm shaft with universal 3/32″ connector, sterile and single-use; pack of 5 units versus 24. Verified in GUDID (DI 00888937010763) and on the manufacturer’s official website. |
| MedGyn Products | Disposable Loop Electrode 10 × 7 mm | 028070 | Comparable by category (not interchangeable 1:1) | Round loop 10 × 7 mm in tungsten wire on a stainless steel shaft of 2.3 mm, sterile and disposable; pack of 5 units. Verified on the manufacturer’s official website and in authorised distribution catalogues (e.g. McKesson). Differs in shaft diameter (2.3 mm) and in units per pack. |
| Gynex Corporation | LLETZ-Radius Loop Electrodes, Single-Use | 12-1007 | Comparable by category (not interchangeable 1:1) | Round loop 10 × 7 mm in 0.20 mm tungsten wire, handle with HexLoc anti-rotation system and standard 3/32″ connector, sterile and single-use; box of 5 units. Verified in the manufacturer’s official catalogue. Differs in presentation. |
There is no equivalence table validated by the manufacturer that allows these references to be treated as direct substitutes for the F4622; consult the technical department before use in tenders. The homologous families on the market for this category (disposable tungsten loops for cervical excision) include the LEEP ranges from CooperSurgical and DTR Medical, LLETZ from Bovie (Aspen Surgical), Megadyne (Ethicon / Johnson & Johnson group), as well as loop electrodes from MedGyn, Medline, Prima Medical and Medtronic. In all cases, the compatibility of the connector with the electrosurgical pencil in use, sterility and the suitability of the geometry for the clinical indication must be checked in the corresponding manufacturer’s technical data sheet.
5. Selection tips and variants of interest
To choose the replacement electrode correctly, first check the shaft diameter accepted by your electrosurgical pencil: the standard Ø 2.38 mm (3/32″) is the most widespread; there are Ø 4 mm versions that require an adapter. Next, select the loop geometry according to the technique: the round 10 × 7 mm format offers a medium-depth excision, ideal for small and medium lesions with a curved contour in the cervical transformation zone; deeper loops (10 × 10 mm, 15 × 10 mm or 20 × 10 mm) allow larger samples, while square, trapezoidal or triangular ones are used depending on the contour and access.
In this same family, interesting variants are offered in boxes of 24 units: F4620 (round 10 × 3 mm), F4621 (round 10 × 5 mm), F4623 (round 10 × 10 mm), F4624 (round 15 × 10 mm) and F4625 (round 20 × 10 mm), as well as the square ranges F4630 (10 × 4 mm), F4631 (10 × 8 mm) and F4632 (10 × 10 mm), the trapezoidal F4640 (30 × 5 mm), the inverted curved F4641 (23 × 13 mm) and the triangular F4642 (17 × 12 mm). For hospital purchases and tendering processes, always verify the CE marking under Regulation (EU) 2017/745 (MDR) and request special volume conditions from our sales department.





Reviews