We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Disposable tungsten electrosurgery electrode, inverted curved loop 23 × 13 mm, shaft Ø 2.38 mm – Box of 24 units (Ref. F4641)

119,71 €

Disposable electrosurgery electrode with an inverted curved loop of tungsten 23 × 13 mm and a universal shaft of Ø 2.38 mm (3/32″), compatible with most electrosurgical pencils on the market. Sterile single-use unit, latex-free, with HIPS anti-shock protector, indicated for cutting and coagulation and LEEP/LLETZ cervical excision in colposcopy. Presentation: box of 24 individually packaged units. Reference F4641, available immediately for hospital supply.

International shipping. Import duties and taxes are payable by the recipient.

Datasheet (opens in a new tab)

Reference
0565068

Description

1. Product Presentation

The disposable electrosurgery electrode Ref. F4641 is a single-use consumable with a tip in loop format inverted curved 23 × 13 mm, made of tungsten wire Ø 0.2 mm and mounted on a stainless steel shaft Ø 2.38 mm (3/32″). It is marketed in a box of 24 units, a format designed to ensure stock rotation and consumption planning in operating theatres, gynaecology units, colposcopy clinics and minor surgery rooms. It is the ideal reference for the professional seeking a reliable, sterile replacement electrode with optimised cost per procedure.

2. Technical explanation of the product and procedure

In monopolar electrosurgery, the active electrode concentrates the high-frequency current emitted by the electrosurgical generator; the energy is applied at the point of contact with the tissue and returns through the dispersive electrode or neutral plate. The geometry of the loop delimits the contact area and allows controlled cutting and coagulation, extracting a tissue sample with defined margins.

The inverted curved sail of 23 × 13 mm (width 23 mm, depth 13 mm) offers wide coverage with a concave profile, ideal for excisions of the cervical transformation zone and for adapting to the contour of larger lesions in LEEP/LLETZ procedures. The tungsten wire provides two clinical advantages over steel: it maintains the shape of the loop throughout the procedure even at high powers and minimises carbonisation and lateral thermal damage, favouring the histological quality of the sample. The Ø 2.38 mm shaft corresponds to the universal compatibility standard of most electrosurgical pencils and handles on the market (3/32″). The hexagonal locking system of the connector prevents rotation of the electrode during use and the high-resistance plastic (HIPS) anti-shock protector protects the professional. Being a single-use product, the risk of cross-contamination and reprocessing costs are eliminated.

3. Technical Specifications

Tip shape Inverted curved loop (sail curve, reverse curved), 23 × 13 mm
Loop dimensions 23 × 13 mm
Loop material Tungsten, Ø 0.2 mm wire
Shaft material AISI stainless steel
Shaft diameter 2.38 mm (3/32″)
Total length 135 mm ± 3%
Insulation / protection High-impact plastic (HIPS) anti-shock protector, latex-free
Compatibility Electrosurgical pencils with universal 2.38 mm (3/32″) connection
Type of use Disposable, single-use
Sterilisation Ethylene oxide (EO); sterile individual packaging (PE envelope + heat-sealed paper pouch)
Presentation Box of 24 units
Regulatory classification Medical device class IIb, in accordance with Directive 93/42/EEC and amendments
Expiry 4 years from production date if stored correctly
Storage Temperature 0 to +50 °C; relative humidity 20–80%
Application Cutting and coagulation; cervical excision (LEEP/LLETZ) in colposcopy and soft tissue surgery
Reference F4641
SKU 0565068

4. Equivalences and Cross-References

There is no equivalence table validated by the manufacturer cross-referencing F4641 with codes from other brands. The following reference is offered as a functional category comparison verified against the official catalogue of the authorised distributor (LESSA / AB Medica Group, Spain), never as a direct 1:1 interchange:

Manufacturer / Brand Family / Model Code / SKU Equivalence level Technical differences / Remarks
AB Medica Group – LESSA Sterile disposable TUNGSTEN LOOP electrode, inverted curved sail 23 × 13 mm 88.200.80 Comparable by category (not interchangeable 1:1) They match in geometry (inverted curved sail), dimensions 23 × 13 mm, length 135 mm, tungsten wire, sterile and presentation of 24 units individually packaged; distribution alternative in Spain. Verified in the official catalogue of distributor LESSA. Confirm shaft diameter and CE marking before replacing stock.

The homologous brands and families on the market for this category (disposable tungsten loops for cervical excision) include the ranges LLETZ Loop Electrodes from Bovie (Aspen Surgical) (refs. ES44, ES47 and ES49), Megadyne™ LLETZ Loops from the Ethicon group (refs. 0420, 0410 and 0440), LEEP Loop Electrodes from CooperSurgical, Disposable Loop Electrodes from MedGyn (refs. 028069 and 028070), Colposcopy LLETZ Loop Electrodes from DTR Medical (refs. LEC1131005-LP and LEC1132010-RE) and the Tungsten Loop Electrodes from Valleylab/Covidien (series E1559–E1562). There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders. Before substituting with another brand, compare shaft diameter, exact tip geometry, sterility, units per package and regulatory classification with the manufacturer’s technical data sheet.

5. Selection tips and variants of interest

To choose the replacement electrode correctly, first verify the shaft diameter accepted by your electrosurgical pencil: the standard Ø 2.38 mm (3/32″) is the most widespread; there are Ø 4 mm versions that require an adapter. Next, select the loop geometry according to the technique: the inverted curved format of 23 × 13 mm offers wide coverage with a concave profile, designed for extensive excisions and lesions with irregular contours in the cervical transformation zone; round loops facilitate smaller curved cuts, square loops provide regular margins and trapezoidal loops allow wide and shallow excisions.

In this same family, interesting variants are offered in boxes of 24 units, all on a Ø 2.38 mm shaft platform and tungsten loop: F4621 (round 10 × 5 mm), F4623 (round 10 × 10 mm), F4624 (round 15 × 10 mm), F4625 (round 20 × 10 mm), F4630 (square 10 × 4 mm), F4631 (square 10 × 8 mm), F4632 (square 10 × 10 mm), F4640 (trapezoidal 30 × 5 mm) and F4642 (triangular 17 × 12 mm). For hospital purchases and tender processes, always verify the CE marking under Regulation (EU) 2017/745 (MDR) and request special volume conditions from our commercial department.

Additional information

Tip shape

Inverted curved loop (reversed curved), 23 × 13 mm

Loop dimensions

23 × 13 mm

Loop material

Tungsten (wire Ø 0.2 mm)

Shaft material

AISI stainless steel

Shaft diameter

2.38 mm (3/32")

Total length

135 mm ± 3%

Protective insulation

HIPS plastic anti-shock protector, latex-free

Compatibility

Electrosurgical pencils with universal 2.38 mm (3/32") connection

Usage type

Disposable, single-use

Sterilisation

Ethylene oxide (EO), individual sterile packaging

Presentation

Box of 24 units

Regulatory classification

Medical device class IIb (Directive 93/42/EEC)

Shelf life

4 years

Storage

0 to +50 °C; relative humidity 20–80%

Manufacturer reference

F4641

Shape

Inverted curved loop (sail curve, reverse curved)

Insulation

High-impact plastic (HIPS) anti-shock protector, latex-free

Application

Cutting and coagulation; cervical excision (LEEP/LLETZ) in colposcopy

Reference

F4641

Latex

Latex-free

Reviews

There are no reviews yet.

Be the first to review “Disposable tungsten electrosurgery electrode, inverted curved loop 23 × 13 mm, shaft Ø 2.38 mm – Box of 24 units (Ref. F4641)”

Your email address will not be published. Required fields are marked *