Description
1. Introduction
The series of monopolar electrodes REGER for dentistry and aesthetics with a Ø 1.6 mm shaft is the solution from German manufacturer REGER Medizintechnik GmbH for precision electrosurgery on soft tissues in the dental and cosmetic field. A complete set of geometries —needle, coagulation needle, balls of various sizes, straight and angled, and coagulation and fulguration electrode— designed to cover everything from fine gingival incisions to spot coagulation and delicate aesthetic work. They are reusable, autoclavable at 134 °C and compatible with high-frequency (HF) and radiofrequency (RF) generators indicated by the manufacturer, making them the reference professional consumable for practices and clinics.
2. Technical Explanation
In monopolar electrosurgery, the high-frequency current is applied in a concentrated manner through the active electrode, enabling precise cuts and controlled coagulation of soft tissue with minimal thermal damage to the surrounding area. Each geometry in this series has its specific indication: the needle electrode (Ø 0.2 mm) and the coagulation needle (Ø 1.5 mm) are used for precision incisions and haemostasis; the ball electrodes of Ø 1.7 mm and Ø 3 mm for spot and surface coagulation, and the combined coagulation and fulguration electrode (Ø 0.6 mm) allows sealing and controlled destruction of tissue. Being reusable and autoclavable at 134 °C, they offer a long service life with the safety of hospital sterilisation, reducing the cost per procedure compared to single-use consumables. The Ø 1.6 mm shaft makes them compatible with the handles and systems of the REGER HF surgery series, as well as with the HF and RF generators indicated by the manufacturer.
3. Technical specifications and available references
Manufacturer’s specifications
| Characteristic | Value |
|---|---|
| Electrode type | Monopolar (needle, ball and coagulation/fulguration) |
| Shaft diameter | Ø 1.6 mm |
| Maximum voltage (Umax) | 4.3 kVp |
| Compatibility | HF and RF generators |
| Reusable | Yes |
| Sterilisation | Autoclavable (134 °C) |
| Units per pack | 5 |
Available references
| REGER reference | Model | Size | Units per pack | Compatible with |
|---|---|---|---|---|
| 402-0 | Angled needle | Diameter Ø 0.2 mm | 5 | HF and RF generators |
| 416-0 | Coagulation needle | Diameter Ø 1.5 mm | 5 | HF and RF generators |
| 417-0 | Ball, angled | Diameter Ø 1.7 mm | 5 | HF and RF generators |
| 417-1 | Ball | Diameter Ø 1.7 mm | 5 | HF and RF generators |
| 418-0 | Angled ball | Measurements Ø 3 mm | 5 | HF and RF generators |
| 418-1 | Ball | Measurements Ø 3 mm | 5 | HF and RF generators |
| 419-0 | Coagulation and fulguration electrode | Measurements Ø 0.6 mm | 5 | HF and RF generators |
4. Equivalences and Cross-References
The references 402-0, 416-0, 417-0, 417-1, 418-0, 418-1 and 419-0 form the REGER series of dental and aesthetic electrodes with a Ø 1.6 mm shaft; they complement each other by geometry and size, without being clinically interchangeable with one another. The manufacturer REGER also offers an analogous family with a Ø 3 mm shaft (references 401-0, 404-0, 405-0 and 406-0) for those who need larger-diameter shafts in the same type of applications. Other manufacturers offer sets of dental electrodes such as the SEL/D series included in the B700/D and B730/D sets from Alsatom (ALSA Apparecchi Medicali), designed for their own handles and electrosurgical units. No direct 1:1 equivalence tables with electrodes from other manufacturers have been found in reliable sources: the clamping systems and handle connectors of brands such as Erbe, KLS Martin or BOWA are specific to each manufacturer, so any replacement must be verified with the technical department before use in tenders.
5. Selection tips and variants of interest
Ref. 402-0 (angled needle Ø 0.2 mm): fine incisions and maximum precision work on the gum and in aesthetics. Ref. 416-0 (coagulation needle Ø 1.5 mm): spot haemostasis and coagulation of small vessels. Refs. 417-0 and 417-1 (ball Ø 1.7 mm, angled and straight): delicate coagulation in small areas. Refs. 418-0 and 418-1 (ball Ø 3 mm, angled and straight): surface coagulation for slightly larger areas. Ref. 419-0 (coagulation and fulguration Ø 0.6 mm): sealing and tissue treatment with controlled fulguration. For correct operation, always use these electrodes with the electrode holder handle suitable for the Ø 1.6 mm shaft diameter and respect the autoclave sterilisation cycles at 134 °C. Consult our technical-commercial team for institutional configurations, supply of complete series or customised quotations.