Description
1. Introduction
The reusable monopolar wire and ribbon loop electrodes with Ø 4 mm shaft from REGER Medizintechnik GmbH are active electrodes designed for excision, resection and coagulation of soft tissue using high-frequency current. Thanks to their reusable nature and autoclave sterilisation at 134 °C, they help optimise the cost per procedure in operating theatres, minor surgery clinics, gynaecology and colposcopy, while maintaining stable cutting performance and excellent specimen preservation.
2. Technical explanation
In a monopolar electrosurgery system, the active electrode concentrates the current emitted by the electrosurgical generator at the point of contact with the tissue, with the circuit returning through the neutral plate. The loop geometry delimits the resection area and allows tissue samples to be taken with defined margins, simultaneously controlling cutting and haemostasis. The Ø 4 mm shaft incorporates hexagonal anti-twist protection, which secures the electrode to the electrode holder handle and prevents accidental rotation during use. These electrodes are suitable for high-frequency (HF) and radiofrequency (RF) generators, with a maximum permissible voltage that reaches, depending on the reference, 500 Vp or 4.3 kVp.
3. Technical Specifications
| Characteristic | Value |
|---|---|
| Electrode type | Reusable active monopolar loop electrode |
| Models | Wire loop and ribbon loop |
| Shaft diameter | Ø 4 mm |
| Use | Reusable |
| Sterilisation | Autoclavable at 134 °C |
| Protection | Anti-twist hexagon (hexagon anti-twist protection) |
| Compatibility | HF and RF generators |
| Maximum voltage (Umax) | 500 Vp (ref. 246-0) · 4.3 kVp (ref. 212-1) |
Available references
| REGER reference | Size | Units per pack |
|---|---|---|
| 212-1 | Wire loop · Diameter Ø 5 mm | 5 |
| 212-2 | Wire loop · Diameter Ø 10 mm | 5 |
| 213-5 | Ribbon loop · Diameter Ø 12 mm | 5 |
| 213-8 | Ribbon loop · Diameter Ø 16 mm | 5 |
| 239-1 | Wire loop · Diameter Ø 5 mm · Length 100 mm | 1 |
| 239-2 | Wire loop · Diameter Ø 10 mm · Length 100 mm | 1 |
| 246-0 | Length 120 mm · Loop Width 10 mm · Loop Height 10 mm | 1 |
| 250-1 | Length 120 mm · Loop Width 15 mm · Loop Height 15 mm | 1 |
| 250-0 | Length 120 mm · Loop Width 20 mm · Loop Height 15 mm | 1 |
| 251-0 | Length 120 mm · Loop Width 20 mm · Loop Height 20 mm | 1 |
| 252-0 | Dimensions 120 mm, 20 mm, 25 mm | 1 |
| 258-0 | Dimensions 120 mm, Ø 10 mm | 1 |
| 259-0 | Dimensions 120 mm, Ø 15 mm | 1 |
| 260-0 | Dimensions 120 mm, Ø 20 mm | 1 |
| 261-0 | Wire loop · Diameter Ø 25 mm · Length 120 mm | 1 |
| 261-1 | Wire loop · Diameter Ø 30 mm · Length 120 mm | 1 |
Data verified according to the REGER Medizintechnik catalogue (reger-medical.de) and the Cahnos-Catalog-Loader.
4. Equivalences and Cross-References
There is no equivalence table validated by the manufacturer that cross-references the 212-1 to 261-1 references of this family with codes from other brands. In the sector there are homologous families of reusable loop electrodes with Ø 4 mm shaft from manufacturers such as Erbe, KLS Martin, Bovie (Aspen Surgical) and Söring, as well as sterile disposable LEEP/LLETZ ranges from CooperSurgical, Megadyne and Medline. These alternatives are offered solely as a functional category comparison, never as direct 1:1 interchangeable items; before any substitution in tenders or surgical protocols, check shaft diameter, connector, fixation system and dimensions with the Cahnos technical department.
5. Selection tips and variants of interest
Select the loop type and size according to the lesion and technique: the wire loops of Ø 5 mm and Ø 10 mm (refs. 212-1 and 212-2, pack of 5 units) are the usual options for small resections and cervical excisions; the ribbon loops of Ø 12 mm and Ø 16 mm (refs. 213-5 and 213-8) offer a larger contact surface for wider resections. For access with a fixed handle, the 239 series (length 100 mm) and 246 to 261 (length 120 mm, with loop width and height from 10 to 25 mm and diameters from Ø 10 to Ø 30 mm) allow the loop size to be precisely adjusted. Always verify that your electrode holder handle accepts a Ø 4 mm shaft with hexagonal anti-twist fixation. As they are reusable, sterilise them in an autoclave at 134 °C after each use and periodically inspect the condition of the loop, removing the electrode if any deformation or deterioration occurs. For hospital purchases, tenders or volume conditions, consult your technical-commercial advisor at Cahnos.





Reviews