Autoclavable electrosurgery loop electrode 20 × 10 mm – Shaft Ø 2.4 mm and 13 cm (Ref. 30688)

10,45 €

20 × 10 mm loop electrode for monopolar electrosurgery in reusable version: shaft Ø 2.4 mm and 13 cm length, autoclavable at 134 °C and supplied non-sterile, therefore it must be sterilised before each use. Indicated for cutting and coagulation with maximum precision and for cervical excision procedures such as LEEP/LLETZ in colposcopy. Class IIb medical device, sales unit: 1 unit. Reference 30688.

Sales unit: 1 unidad
Minimum order for products shipped from Italy: 150,00 € excluding VAT (can be combined)

Delivery time: 15 days

International shipping. Import duties and taxes are payable by the recipient.

Reference
GM30688

You will also find it in

Description

1. Product Presentation

The 20 × 10 mm loop electrode (Ref. 30688) is a reusable active electrode designed for monopolar electrosurgery. Its loop geometry of 20 mm width and 10 mm depth, mounted on a shaft of Ø 2.4 mm and 13 cm length, offers wide, clean and controlled excision. Being autoclavable at 134 °C and non-sterile, it allows reprocessing and reuse in the operating theatre with excellent cost per procedure, making it the ideal choice for gynaecology departments, colposcopy clinics, minor surgery units and operating theatres working with electrosurgical pencils and generators.

2. Technical explanation of the product and procedure

In monopolar electrosurgery, the active electrode concentrates the high-frequency current emitted by the electrosurgical generator; the energy is applied at the point of contact with the tissue and returns through the neutral plate or dispersive electrode. The loop geometry delimits the contact area and allows simultaneous and controlled cutting and coagulation, extracting a tissue sample with defined margins.

The 20 × 10 mm profile (width × depth) offers a wide excision, suitable for larger lesions in the cervical transformation zone and for loop electrosurgical excision procedures (LEEP/LLETZ) in colposcopy, as well as for soft tissue surgery. The Ø 2.4 mm shaft with 13 cm length ensures adequate ergonomics and good accessibility. As a reusable product, it must be reprocessed after each patient following the recommended sterilisation cycles (autoclave at 134 °C, according to the manufacturer’s data sheet).

3. Technical Specifications

Characteristic Value
Electrode width 20 mm
Electrode depth 10 mm
Shaft diameter Ø 2.4 mm
Stem length 13 cm
Autoclavable Yes, at 134 °C
Sterility Non-sterile (requires sterilisation before use)
Application Cutting and coagulation; cervical excision (LEEP/LLETZ) and soft tissue surgery

Product data

Manufacturer GIMA
Sales unit 1 pc (1 unit)
Device type Medical device
Device class II B
CND K02030101
EAN 8023279306880

4. Equivalences and Cross-References

No equivalence table validated by the manufacturer cross-referencing code 30688 with codes from other brands has been found in reliable sources, therefore no direct 1:1 equivalents are indicated; consult the technical department before use in tendering.

As a functional category reference (not interchangeable), the Cahnos catalogue offers disposable tungsten loop electrodes for similar cervical excision procedures (families F4620–F4625 round and F4630–F4632 square), which share the same LEEP/LLETZ clinical indication but differ in being sterile single-use consumables with a Ø 2.38 mm (3/32″) shaft. There are also homologous families of reusable LEEP/LLETZ electrodes from other manufacturers on the market; always verify shaft diameter, exact loop geometry and compatibility system with the electrosurgical pencil in use.

5. Selection tips and variants of interest

To choose the correct electrode, first verify the shaft diameter accepted by your electrosurgical pencil or handle: in this reference the shaft is Ø 2.4 mm, so compatibility with your electrosurgery inventory must be confirmed. Next, select the loop geometry according to the technique: the 20 × 10 mm format offers a wide and homogeneous excision, indicated for larger lesions; for smaller lesions, loops with smaller coverage are preferable (e.g. 10 × 5 mm, 10 × 10 mm or 15 × 10 mm).

Remember that this electrode is supplied non-sterile and is reusable: it must be reprocessed in an autoclave at 134 °C following the manufacturer’s instructions and the centre’s regulations. For hospital purchases, operating theatre supplies or tendering processes, request a quote from our technical-commercial department.

Additional information

Manufacturer reference

30688

Loop dimensions

20 × 10 mm (width × depth)

Shaft diameter

Ø 2.4 mm

Stem length

13 cm

Autoclavable

Yes, at 134 °C

Sterility

Non-sterile (requires sterilisation before use)

Unit of sale

1 pc (1 unit)

Device type

Medical device (Medical device)

CND code

K02030101

EAN

8023279306880

Application

Cutting and coagulation in monopolar electrosurgery; cervical excision (LEEP/LLETZ) and soft tissue surgery

Presentacion

Unit

Tipo dispositivo

Medical device

Clase sanitaria

II b

Tipo uso

Reusable

Documentation

📄 DatasheetEnglish PDF
📜 Declaration of conformityEnglish PDF
📜 CE certificateDownload PDF
📜 ISO 9001 / 13485 certificatesMultilingüe PDF

Reviews

There are no reviews yet.

Be the first to review “Autoclavable electrosurgery loop electrode 20 × 10 mm – Shaft Ø 2.4 mm and 13 cm (Ref. 30688)”

Your email address will not be published. Required fields are marked *