We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

FirePen bipolar vapourisation electrodes from REGER for arthroscopy (RF plasma system)

Price on request

Range of FirePen bipolar vapourisation electrodes from REGER for the RF plasma arthroscopy system. Ideal for tissue cutting and coagulation in arthroscopic surgery of the shoulder, knee and other joints, with low-temperature technology, single-use system, suction tube in the versions that incorporate it and Plug & Play connection. Available in angles of 45°, 70° and 90°, with and without suction, and fine or standard hook variants. References: 893-37s, 893-38s, 893-39s, 893-41s, 893-43s, 893-24s, 893-25s and 893-42s, all 150 mm in length. Sold on a quotation basis.

International shipping. Import duties and taxes are payable by the recipient.

Reference
RGR-FIREPEN

Description

FirePen bipolar vapourisation electrodes from REGER

The FirePen range from REGER Medizintechnik GmbH brings together bipolar vapourisation electrodes designed specifically for the manufacturer’s RF plasma arthroscopy system. It is a complete single-use system designed to offer precision, control and efficiency during arthroscopic procedures, ensuring reproducible workflow and great comfort for the surgical team.

Technical explanation of the equipment

The FirePen electrodes work with low-temperature RF plasma technology, allowing controlled tissue cutting and coagulation in arthroscopic procedures. The system incorporates a suction tube in the versions that include it, has a non-obstructive design and Plug & Play connection to simplify its preparation in the operating theatre. Being a single-use system eliminates the costs and times associated with reprocessing. The range includes different tips and angles (45°, 70° and 90°) to adapt to the anatomy and type of intervention, and is compatible with various RF generators, allowing integration with the handles and adapters of the REGER ecosystem.

Technical specifications

Manufacturer’s specifications

Characteristic Value
Length 150 mm
System Low-temperature RF plasma
Type of use Single-use
Connection Plug & Play
Manufacturer REGER Medizintechnik GmbH

Available references

REGER reference Angle Suction Size Reference
893-37s 90° With suction Standard 893-37s
893-38s 45° With suction Standard 893-38s
893-39s 45° With suction Standard 893-39s
893-41s 45° With suction Bendable yes · Single use yes 893-41s
893-43s 70° Without suction Standard 893-43s
893-24s 90° Without suction Fine hook 893-24s
893-25s 90° Without suction Standard hook 893-25s
893-42s 90° Without suction Standard 893-42s

Equivalences and cross-references

The FirePen electrodes are part of the REGER plasma arthroscopy system, which also includes the RF plasma generator (ref. 897-10 and 897-10V), the foot pedal (ref. 897-7) and the reusable bipolar handles. Each FirePen reference has its equivalent in the BiVac series from the same manufacturer (for example, 893-37s is equivalent to the 90° suction electrode configuration type 890-1s). The REGER system also offers adapters that allow compatibility with the most common third-party generators on the market (Arthrex, Arthrocare, Mitek VUE, Mitek Vapr, BONSS and Ellman), facilitating integration into existing surgical infrastructures.

Selection tips and variants of interest

For shoulder and knee procedures requiring evacuation of vaporised tissue, the versions with suction are recommended: 893-37s (90°), 893-38s (45°), 893-39s (45°) and the bendable 893-41s (45°, single-use), which allows the tip geometry to be adapted to the approach. When access without suction is required, the options are 893-42s (90°) and 893-43s (70°). For precision hook work, the variants 893-24s (fine hook, 90°) and 893-25s (standard hook, 90°) are indicated. All references share 150 mm length and are sold on a quotation basis; consult our sales team to configure the most suitable combination for your generator fleet.

Additional information

Ángulo

90°, 45°, 70°

Aspiración

Con aspiración, Sin aspiración

Medida

Estándar, Bendable yes · Single use yes, Hook fino, Hook standard

Referencia

893-37s, 893-38s, 893-39s, 893-41s, 893-43s, 893-24s, 893-25s, 893-42s

Manufacturer

REGER Medizintechnik GmbH

System

Bipolar RF plasma vapourisation electrode

Available angles

45°, 70°, 90°

Hook

Fine and standard depending on reference

Technology

Low-temperature RF plasma, non-obstructive

Connection

Plug & Play

References

893-37s, 893-38s, 893-39s, 893-41s, 893-43s, 893-24s, 893-25s, 893-42s

Application

Shoulder, knee and joint arthroscopy

Longitud

15 cm

Tipo uso

Single-use

Reviews

There are no reviews yet.

Be the first to review “FirePen bipolar vapourisation electrodes from REGER for arthroscopy (RF plasma system)”

Your email address will not be published. Required fields are marked *