Reusable adapter for electrosurgery pencil with manual switch, from Valleylab-type connector to 4 mm plug – Compatible with Berchtold and Martin equipment · FIAB Ref. F4831

Price on request

Reusable adapter FIAB F4831 for electrosurgery pencils with manual switch: converts the Valleylab-type pencil connection to a 4 mm male plug, allowing its use with equipment from manufacturers Berchtold and Martin. Robust and practical solution to expand the compatibility of your fleet of switched pencils in the operating theatre, avoiding having to change handles depending on the generator available. It is supplied as a single unit, ready to be incorporated into the service’s reusable instruments.

International shipping. Import duties and taxes are payable by the recipient.

Reference
FIAB-F4831
Brand
FIAB

Description

Adapter for hand-held electrosurgery pencil FIAB Ref. F4831

The FIAB F4831 adapter is the connection piece that your electrosurgery service needs to make the most of its handswitch pencils. It is a reusable adapter that converts the Valleylab-type output of the pencil into a 4 mm male plug, allowing that same handle to be connected to equipment from manufacturers Berchtold and Martin. A single reference solves the interconnection between different connection systems, simplifying the material in the operating theatre and reducing the need to purchase brand-specific pencils.

Technical product explanation

In monopolar electrosurgery, the pencil (electrosurgical unit) is the active electrode handled by the surgeon and which incorporates, in versions with a manual switch, the cut and coagulation buttons on the handle itself. The pencil is connected to the electrosurgical generator through a female connector that can adopt various standards: the Valleylab type (three-socket connection) is one of the most widespread, while numerous European devices use the 4 mm male plug as the input standard. The F4831 adapter precisely resolves this transition (from Valleylab-type connector to 4 mm male plug), so that the same switched pencil can be used with equipment from different brands. Being reusable, it is incorporated into the service’s instrument set and reprocessed according to the centre’s usual protocol, providing versatility and cost containment compared with purchasing specific handles for each generator model.

Technical specifications

Characteristic Value
Product type Reusable adapter for electrosurgery pencil with manual switch
Connection conversion From Valleylab-type connector to 4 mm male plug (plug)
Equipment compatibility Berchtold and Martin devices
Use Reusable
Manufacturer FIAB SpA (Vicchio, Florence, Italy)

Manufacturer’s specifications

Characteristic Value
Reference FIAB F4831
Packaging Single unit
Units per box (web) 1

Available references

Reference FIAB Description
F4831 Reusable adapter for handswitch pencils, from Valleylab type to 4 mm plug, compatible with Berchtold and Martin equipment

Equivalences and cross-references

There is no manufacturer-validated equivalence table that directly cross-references the F4831 reference 1:1 with codes from other brands. The F4831 reference belongs to the FIAB family of reusable adapters (range F4830–F4834) for electrosurgery pencils, within which adaptations to Erbe, Berchtold and Martin equipment are contemplated. Before using this reference as a substitute for material from another brand or in tendering processes, it is recommended to consult the technical department and verify the connection standard of the generator and the pencil in use.

Selection tips and variants of interest

Before choosing an adapter, identify the connector on the electrosurgical generator and the output type of your pencil: if your switched pencil ends in a Valleylab-type connector and the equipment accepts a 4 mm plug, the F4831 adapter is the solution for Berchtold and Martin equipment. Also check the diameter of the electrode shaft (standard Ø 2.38 mm / 3/32″) and the presence of a switch on the handle. Within the same FIAB family, other adaptation references (F4830–F4834) are offered for different generator standards and brands; if your inventory includes several connection systems, consider having a set of adapters to guarantee universal compatibility of the instruments in the operating theatre. Products are supplied on quotation; contact your sales representative for volume purchase conditions and delivery times.

Additional information

Brand

FIAB

Packaging

Single unit

Manufacturer reference

F4831

Manufacturer

FIAB SpA (Vicchio, Florence, Italy)

Product type

Reusable adapter for electrosurgery pencil with manual switch

Connection conversion

From Valleylab-type connector to 4 mm male plug (plug)

Compatibility

Berchtold and Martin equipment

Presentation

Single unit

Units per box

1

Tipo uso

Reusable

Documentation

Reviews

There are no reviews yet.

Be the first to review “Reusable adapter for electrosurgery pencil with manual switch, from Valleylab-type connector to 4 mm plug – Compatible with Berchtold and Martin equipment · FIAB Ref. F4831”

Your email address will not be published. Required fields are marked *