Description
1. Product Introduction
The Ø 4 mm electrode extenders from REGER Medizintechnik GmbH (Germany) are the essential complement for extending the reach of the manufacturer’s monopolar electrodes in the HF range in operating theatres, minor surgery clinics, dermatology and ambulatory surgery centres. Designed to work with handles and electrode-holder systems with a Ø 4 mm shaft, these extenders allow comfortable access to deep fields and hard-to-reach areas without compromising the precision of the surgical gesture. Like the rest of the REGER electrosurgery range, they are reusable, autoclavable at 134 °C and compatible with high-frequency (HF) and radiofrequency (RF) generators.
2. Technical explanation
In monopolar electrosurgery, the high-frequency current is transmitted from the generator through the active electrode, which concentrates the current density at the tip to cut and coagulate tissue. The electrode extender acts as an intermediate connection element between the electrode-holder handle and the active tip, increasing the useful length of the working assembly and improving ergonomics in deep or restricted-access surgical fields.
This model incorporates hexagonal anti-rotation protection, which prevents the electrode from rotating inside the handle and ensures a stable and reproducible orientation of the tip during the procedure. The assembly is reusable and sterilised in an autoclave at 134 °C, offering a long service life and a lower cost per procedure compared with single-use consumables, with a maximum rated voltage of 4.3 kVp, sufficient to cover standard cutting and coagulation applications in HF and RF.
3. Technical specifications and available references
Common features of the REGER electrode extender family with a Ø 4 mm shaft:
| Characteristic | Value |
|---|---|
| Brand / Manufacturer | REGER Medizintechnik GmbH (Germany) |
| Accessory type | Electrode extender (extension) |
| Diameter | 4 mm |
| Maximum voltage (Umax) | 4.3 kVp |
| Compatibility | HF and RF generators |
| Protection | Hexagonal anti-rotation |
| Type of use | Reusable |
| Sterilisation | Autoclave (134 °C) |
| Units per pack | 1 |
Manufacturer’s specifications
| Characteristic | Value |
|---|---|
| Diameter | 4 mm |
| Maximum voltage (Umax) | 4.3 kVp |
Available references
| REGER reference | Length | Units per pack | Compatible with |
|---|---|---|---|
| 274-7 | 200 mm | 1 | HF and RF generators |
| 274-6 | 150 mm | 1 | HF and RF generators |
| 274-5 | 100 mm | 1 | HF and RF generators |
| 274-4 | 80 mm | 1 | HF and RF generators |
4. Equivalences and Cross-References
The Ø 4 mm electrode extender family from REGER (series 274: refs. 274-7, 274-6, 274-5 and 274-4) is registered in Cahnos under SKUs RGR-274-7, RGR-274-6, RGR-274-5 and RGR-274-4, in addition to the family SKU RGR-HF-PROLONG-4. All share the Ø 4 mm shaft diameter, the hexagonal anti-rotation protection and the maximum voltage of 4.3 kVp.
Within REGER’s own catalogue there is the equivalent family of extenders with a Ø 2.4 mm shaft (series 374: refs. 374-7, 374-6, 374-5 and 374-4), designed for electrode-holder handles of smaller diameter, with the same reuse and autoclaving performance at 134 °C. These two series should not be considered interchangeable: the shaft diameter determines compatibility with the handle.
No reliable sources have been found for a 1:1 equivalence table validated by the manufacturer with extenders from other brands. The handle clamping systems and connectors from manufacturers such as Erbe, KLS Martin or BOWA are specific to each house, so any replacement must be verified with our technical department before considering alternatives in tenders.
5. Selection tips and variants of interest
Select the length of the extender according to the depth of the surgical field: ref. 274-4 (80 mm) is ideal for superficial fields and precision gestures; ref. 274-5 (100 mm) and ref. 274-6 (150 mm) cover most general and minor surgery procedures; and ref. 274-7 (200 mm) offers the maximum reach for deep fields, allowing hands and handle to be kept out of the working area.
Always combine these extenders with Ø 4 mm shaft electrodes and handles from the REGER HF range and respect the autoclave sterilisation cycles at 134 °C. If your electrode-holder handle uses a Ø 2.4 mm diameter, consider the series 374 extender family. For hospital equipment, custom configurations or institutional budgets, contact our technical-commercial team at Cahnos.






Reviews
There are no reviews yet.