We present the original connection cable FIAB (Ref. F7902/24) for disposable neutral plates, an essential accessory to complete the monopolar circuit of your electrosurgery with maximum reliability. With a length of 500 cm and double 4 mm plug, it connects the single-use return plate directly to the electrosurgical unit and is used with cableless disposable plates with tab (TAB) connection.
It is the usual choice in operating theatres, ambulatory major surgery centres, minor surgery clinics, dermatology, dentistry and veterinary clinics that work with disposable neutral plates and want a safe and stable return contact between the plate and the generator in each procedure.
2. Technical explanation
In monopolar electrosurgery, the high-frequency current leaves through the active electrode (handle or pencil), passes through the patient’s tissue and must return to the generator through a low current density path: the neutral plate or return electrode. The quality of that return path depends both on the plate and on the cable that connects it to the equipment.
This FIAB F7902/24 cable guarantees that connection with a double 4 mm plug configuration, the usual return socket on many electrosurgical generators. When working with cableless disposable plates with tab (TAB) connection, the plate-cable assembly ensures a low and stable contact impedance, an essential condition to avoid current density concentrations that could lead to patient burns. Periodically check the condition of the cable (insulation integrity and connectors) and replace it at any sign of deterioration to ensure correct and safe electrical contact.
3. Technical Specifications
Manufacturer’s specifications
| Characteristic | Value |
|---|---|
| Reference FIAB | F7902/24 |
| Packaging | Single unit |
| Units per box (web) | 1 |
Product features
| Characteristic | Value |
|---|---|
| Brand / Manufacturer | FIAB / FIAB SpA (Vicchio, Florence, Italy) |
| Product type | Connection cable for disposable neutral plate (return electrode) |
| Length | 500 cm |
| Connector | Double 4 mm plug |
| Plate type | Disposable neutral plates without cable with tab connection (TAB) |
| Use | Disposable neutral plates (single-use return electrodes) |
| Presentation | Loose unit (1 unit per web box) |
Available references
| Reference | Description | Length |
|---|---|---|
| F7902/24 | Cable with double 4 mm plug, for disposable plate | 500 cm |
4. Equivalences and Cross-References
This cable belongs to the FIAB range of connection cables for disposable neutral plates. Depending on the generator connector installed in your facility, it can be complemented with these references from the same commercial family:
| Reference | Description |
|---|---|
| F7902 | Universal cable, 6.3 mm mono jack connector, for disposable plate, 500 cm |
| F7902/4 | Cable with 4 mm plug, for disposable plate, 500 cm |
| F7902/24 | Cable with double 4 mm plug, for disposable plate, 500 cm |
| F7903 | Valleylab type cable, for disposable plate, 500 cm |
| F7904 | Special 6.3 mm mono jack cable for ERBE (ACC, ICC, VIO, T), for disposable plate, 500 cm |
For reusable neutral plates with a 4 mm socket, the homologous FIAB family consists of references F7922/24 (double 4 mm plug), F7922/4, F7922, F7922/WB, F7923, F7923/F and F7924 (ERBE). There is no official equivalence table validated by the manufacturer with cables from other brands; before any replacement, confirm with our technical department the compatibility of the connector with your generator and with the neutral plate in use.
5. Selection tips and variants of interest
Check your equipment connector: reference F7902/24 uses a double 4 mm plug. If your generator requires a single 4 mm plug, consider reference F7902/4; if you use a Valleylab-type connector, reference F7903; for a universal 6.3 mm jack, F7902; and for ERBE-type equipment (ACC, ICC, VIO, T), F7904.
Compatible plate: use it with cableless disposable neutral plates with tab (TAB) connection from the FIAB range (series F7805 and F7820, in adult, paediatric and neonatal versions). To extend compatibility with Valleylab-type connection plates, the reusable adapters F4828 (to 4 mm plug) and F4829 (to 6.3 mm plug) can be used.
Maintenance and inspection: check the insulation and connectors before each procedure and replace the cable at any sign of degradation, as a faulty return contact can compromise patient safety.
This product is sold on quotation; contact our technical-commercial department for special B2B conditions or operating theatre equipment.