Description
1. Presentation
The rubber plate cable (ref. 30575) is the connection accessory that completes the monopolar electrosurgery system when working with the reusable rubber neutral plates with codes 30573 and 30574. It guarantees a stable and reliable connection between the return plate and the electrosurgical unit, maintaining the integrity of the high-frequency signal during the procedure. It is the ideal solution for operating theatres, minor surgery rooms, dermatology, dentistry and veterinary clinics that use reusable plates and seek to reduce the recurring cost of disposable electrodes.
2. Technical explanation
In monopolar electrosurgery, the high-frequency current leaves through the active electrode (handpiece or pencil), passes through the patient’s tissue and must return to the generator through the neutral plate, which acts as the return electrode. The rubber plate cable transmits this current back to the electrosurgical unit from the conductive reusable rubber plate, safely closing the circuit. This accessory is specifically intended by the manufacturer for the reusable rubber plates with references 30573 and 30574, ensuring correct connector fit and optimal electrical contact. Thanks to its flexibility, the rubber plate adapts to the patient’s anatomy and offers a wide, uniform contact surface, an essential requirement for the correct operation of the equipment’s safety circuit.
3. Technical Specifications
Data verified according to the manufacturer’s official catalogue (Product_DB.csv).
| Manufacturer | GIMA |
|---|---|
| Manufacturer reference | 30575 |
| SKU Cahnos | GM30575 |
| Compatibility | Reusable rubber electrosurgical plates codes 30573 and 30574 |
| Use | Monopolar electrosurgery accessory: rubber plate – electrosurgical unit connection |
| Sales unit | 1 pc |
| Device type | Medical device |
| Device class | I |
| CND | Z12010980 |
| GMDN | 35042 |
| EAN | 8033695724861 |
4. Equivalences and Cross-References
This product corresponds to reference 30575 in the manufacturer’s catalogue (marketed in Cahnos as GM30575). The cable is specifically designed to complete the system formed by the reusable rubber plates with codes 30573 and 30574.
| Reference | Description | Sales unit |
|---|---|---|
| 30575 | Cable for rubber plates (return electrode) for codes 30573 and 30574 | 1 pc |
| 30573 | Reusable rubber electrosurgical plate compatible with this cable | 1 pc |
| 30574 | Reusable rubber electrosurgical plate compatible with this cable | 1 pc |
No official 1:1 equivalence table published by the manufacturer that cross-references this reference with cables from other brands has been found in reliable sources; any substitution must be validated field by field (connector, length, insulation and generator compatibility) with the technical department of Cahnos.
5. Selection tips and variants of interest
Verify that your installed base of electrosurgical units supports reusable plates and select the appropriate rubber plate (ref. 30573 or 30574) together with this connection cable (ref. 30575) to complete the system. For other accessories in the electrosurgery range, such as 4 mm monopolar connection cables for monopolar instruments (refs. 30609 and 30610) or bipolar cables, consult our catalogue. Periodically inspect the cable and the plate: if it shows cuts, cracks, kinks or loss of conductivity, it must be replaced to ensure patient safety. For institutional orders, tenders or volume supply agreements, contact our technical-commercial team.





Reviews
There are no reviews yet.