Description
1. Introduction
The adult replacement cuff ref. 35146 is the manufacturer’s original non-invasive blood pressure (NIBP) cuff for the CMS 8000 patient multiparameter monitor (ref. 35152). Designed for adult patients with an arm circumference of 25 to 35 cm, it restores blood pressure measurement on your monitor without the need to purchase a complete unit, making it the most economical and agile solution for diagnostic services, emergency departments, hospitalisation wards, outpatient clinics and critical care units that keep these devices in continuous use.
As an original-quality replacement part, it ensures a correct fit, a reliable inflatable bladder and a connection compatible with the monitor’s pressure connector, ensuring stable readings on every measurement. For large orders you can request a quote: contact our technical-commercial team for B2B terms and availability.
2. Technical explanation
The CMS 8000 multiparameter monitor (ref. 35152) measures blood pressure using the oscillometric method (NIBP), in manual, automatic and continuous modes. To do so, it uses a cuff fitted with an inflatable bladder that is placed around the patient’s arm: when inflated, the bladder occludes the brachial artery and, during progressive deflation, the monitor detects the oscillations of the pulse wave through the connection tube to calculate systolic, diastolic and mean pressure.
This adult cuff is sized for an arm circumference of 25-35 cm, the standard range in the adult population. An appropriate cuff size is key to obtaining accurate measurements: a cuff that is too small or too large distorts blood pressure values. Its reusable design, with a durable air bladder and Velcro closure system, allows prolonged use in high-turnover healthcare environments, with only the part being replaced when the bladder, tube or closure deteriorates.
3. Technical Specifications
This cuff is supplied as a replacement (spare) for the original NIBP cuff of the CMS 8000 multiparameter monitor (ref. 35152). Always check the reference of your device before ordering the replacement.
| Parameter | Specification |
|---|---|
| Manufacturer reference | 35146 |
| Accessory type | Adult NIBP cuff / arm cuff |
| Arm circumference | 25-35 cm |
| Patient population | Adults |
| Compatibility | Multiparameter monitor CMS 8000 (ref. 35152) |
| Use | Reusable replacement (spare) |
| Measurement method | Oscillometric (NIBP) |
| Product data | |
|---|---|
| Manufacturer | GIMA |
| Sales unit | 1 pc |
| Device type | Medical device (Medical device) |
| Device class | I |
| CND | Z12040185 |
| EAN | 6945040101666 |
4. Equivalences and Cross-References
Reference 35146 is the manufacturer’s own catalogue code for the adult replacement cuff for the CMS 8000 monitor (35152). The manufacturer uses connectors and calibrations specific to each equipment family, so we do not have a manufacturer-validated equivalence table that cross-references this cuff with codes from other brands on a 1:1 interchangeable basis. Before replacing a cuff with one from another manufacturer, always check the compatibility of the connector, tube length and size with the exact make and model of your monitor.
Within the same range, the multiparameter monitor ref. 35213 shares an accessory family with the CMS 8000 (35152). Likewise, the monitoring accessories designed for these devices include the adult SpO2 catheter ref. 35153, the reusable paediatric catheter ref. 35215 and the neonatal catheter ref. 35216, which can be combined with this cuff to complete the set of replacement parts for the monitoring station.
5. Selection tips and variants of interest
- Check your monitor: this cuff is the correct replacement for the CMS 8000 multiparameter monitor (ref. 35152). Always confirm the full reference of your device before placing your order.
- Choose the correct size: for an arm circumference of 25-35 cm in the adult population, this is the standard size. If your department also treats paediatric or neonatal patients, consult the specific accessories in the catalogue to select the appropriate cuff according to the patient’s size.
- Maintenance: periodically check the condition of the bladder, tube and Velcro closure. A cuff with air leaks, a kinked tube or a worn closure produces inaccurate measurements and must be replaced.
- Stock management: as this is a frequently used replacement part, we recommend keeping at least one spare unit per monitor to avoid interruptions in patient monitoring.
- B2B terms: Contact our technical-commercial department at Cahnos for terms, lead times and availability.