Description
1. Commercial Introduction
The 24-hour ambulatory blood pressure (ABPM) Holter with pulse and SpO2 measurement (ref. 35111) is the comprehensive ambulatory monitoring solution for cardiology, primary care, internal medicine, diagnostic units, pharmacies and nursing services. This compact, portable device allows continuous blood pressure recording over a full day, adding the advantage of simultaneously measuring pulse rate and oxygen saturation (SpO2), without the need for additional equipment.
Designed to detect hypertension patterns, assess nocturnal blood pressure dip and evaluate the effectiveness of pharmacological treatment, the device combines a colour LCD screen, adjustable alarms and clinically proven accuracy, with simple operation both in the clinic and at the patient’s home.
2. Technical explanation of the equipment
The ABPM module measures blood pressure using the oscillometric method with gradual deflation. The device has two measurement modes: in manual mode a single measurement is taken per reading, while in automatic mode measurements are performed cyclically at programmable intervals of 5/10/15/20/30/45/60/90/120 minutes. In both modes, systolic pressure, diastolic pressure and mean arterial pressure (MAP) are displayed on screen, together with pulse rate and oxygen saturation.
SpO2 measurement allows non-invasive assessment of blood oxygen saturation levels, with a range of 0-100%, resolution of 1% and accuracy of ±2% in the 70-100% range. Its adjustable audible and visual alarms, 24-hour data storage and review, and suitability for adult, paediatric and neonatal patients make it a versatile device for daily clinical practice. Data is transferred to a PC using the included software, compatible with 32-bit and 64-bit Windows systems.
3. Technical Specifications
SpO2 measurement
| Parameter | Specification |
|---|---|
| Measurement range | 0-100 % |
| Resolution | 1 % |
| Accuracy | 70-100 % ±2 % |
| Alarm range | 0-100 % |
NIBP method (non-invasive blood pressure)
| Parameter | Specification |
|---|---|
| Method | Oscillometry with gradual deflation |
| Modes | Manual / automatic / continuous |
| Measurement range | 0-290 mmHg (0 KPa – 38.67 KPa) |
| Automatic measurement interval | 5/10/15/20/30/45/60/90/120 min |
| Resolution | 1 mmHg |
| Overpressure protection | 290 mmHg |
Alarms
| Parameter | Range |
|---|---|
| Systolic | 40-270 mmHg |
| Diastolic | 20-235 mmHg |
| Mean arterial pressure (MAP) | 10-270 mmHg |
Pulse rate
| Parameter | Specification |
|---|---|
| Range | 0-250 lpm |
| Resolution | 1 bpm |
| Accuracy | ±1 bpm |
| Alarm range | 30-250 bpm |
Device
| Parameter | Specification |
|---|---|
| Display | Colour LCD |
| Power supply | 2 alkaline “AA” batteries of 1.5 V |
| Dimensions | 128 x 69 x 36 mm |
| Weight | <350 g (including batteries) |
| Operating system | Windows XP/Seven, 8, 8.1, 10, 11 (32 and 64 bits) |
Included accessories
- Carry bag
- Multilingual software (GB, FR, IT, DE, ES, PL, RO, SK, TR, RU)
- 3 nylon cuffs (paediatric, adult and adult large) – latex-free
- SpO2 probe
- 1.5 m cuff connection tube
- User manual (GB, IT, FR, ES, PT, SE)
- Alkaline batteries
Product data
| Value | Value |
|---|---|
| Manufacturer | GIMA |
| Manufacturer reference | 35111 |
| Sales unit | 1 pc |
| Device type | Medical device |
| Device class | II B |
| CND | Z129010 |
| GMDN | 12849 |
| EAN | 8023279351118 |
4. Equivalences and Cross-References
The original manufacturer reference is Ref. 35111 (SKU Cahnos: GM35111). Within the same ambulatory monitoring family are:
| Reference | Description |
|---|---|
| GM35110 (ref. 35110) | ABPM Holter + pulse without SpO2 measurement (intervals from 15 to 240 min), without Bluetooth |
| GM35112 (ref. 35112) | ABPM Holter + pulse with Bluetooth (intervals from 15 to 240 min), without SpO2 |
| GM35113 (ref. 35113) | Paediatric NIBP cuff (arm circumference 18-26 cm) |
| GM35115 (ref. 35115) | Adult large NIBP cuff (arm circumference 33-47 cm) |
| GM35117 (ref. 35117) | 1.5 m cuff extension tube |
| Ref. 35118 | Spare SpO2 probe |
| Ref. 35119 | Carry bag |
No reliable sources provide a direct 1:1 equivalence table with other manufacturers for this reference: the compatibility of cuffs, SpO2 probe and accessories with the device must always be verified with the original spare part.
5. Selection tips and variants of interest
When configuring your 24-hour ambulatory monitoring system, consider which parameters you need to record: if you require blood pressure, pulse and oxygen saturation (SpO2) in a single device, this variant (GM35111) is the most complete option in the family: it includes an SpO2 probe and allows shorter automatic cycles (from 5 minutes), compared to the 15 minutes of the rest of the series. If you only need blood pressure and pulse with software transfer, the GM35110 model is the alternative; if you also need Bluetooth connectivity with a smartphone, the GM35112 includes wireless transfer.
Check the appropriate cuff size for the patient’s arm circumference (the set includes three sizes: paediatric, adult and adult large, latex-free) and periodically replace cuffs, tubing and SpO2 probe with original spare parts to maintain accuracy and hygiene of readings. For institutional orders, tenders and purchasing groups, contact the technical-commercial department of Cahnos to validate the technical data sheet and the device’s conformity documentation. For large orders you can request a quote.







Reviews