Description
1. Commercial Introduction
The Premium infant cuff (ref. 32887) is the original high-resistance replacement that your service needs to maintain the accuracy and hygiene of your dual-connection blood pressure monitors and sphygmomanometers. Made from high-quality 210D nylon in dark grey, with a TPU internal bladder and quick-closing Velcro, it is designed for intensive professional use in paediatric clinics, primary care, nursing units and pharmacies. As a factory-made part, it preserves the fit, comfort and inflation behaviour required by the original equipment.
2. Technical explanation of the accessory
The cuff is the component of the sphygmomanometer that wraps around the patient’s arm and transmits pressure during oscillometric or auscultatory measurement. When inflated, the internal bladder temporarily occludes the brachial artery and, when deflated in a controlled manner, allows detection of Korotkoff sounds or oscillations of the oscillometric method. This 2-tube version integrates the TPU air bladder inside a high-tenacity 210D nylon outer cover and is adjusted with Velcro to the limb contour. The infant size ensures correct contact on arms with a circumference of 13 to 19 cm, an essential condition for obtaining reliable readings: an inappropriate size distorts pressure values. The manufacturer certifies a durability of up to 10,000 inflation cycles, ensuring a long service life even in high-turnover environments.
3. Technical Specifications
| Characteristic | Specification |
|---|---|
| Model / size | Infant (baby) |
| Connection type | 2 tubes |
| Cuff measurements | 7.5 x 26 cm |
| Arm circumference | 13 – 19 cm |
| Exterior material | High-quality 210D nylon |
| Bladder (bellows) | TPU (thermoplastic polyurethane) |
| Closure | Velcro (quick fastening) |
| Colour | Dark grey |
| Durability | Tested up to 10,000 cycles |
| Compatibility | 2-tube blood pressure monitors: Minor, Yton line, Roma 2T, Dallas, Big Ben, Empire, Dayton… |
Available references
| Reference | Description | Sales unit |
|---|---|---|
| Ref. 32887 (GM32887) | Premium infant cuff with TPU bladder, 2 tubes · 7.5 x 26 cm · Arm 13-19 cm · Dark grey | 1 pc |
Product data
| Manufacturer | GIMA |
|---|---|
| Manufacturer reference | 32887 |
| Sales unit | 1 pc |
| Device type | Medical device (Medical device) |
| Device class | I |
| CND | C99 |
| GMDN | 34978 |
| EAN | 8023279328875 |
4. Equivalences and Cross-References
This cuff corresponds to the manufacturer’s official reference Ref. 32887 (SKU Cahnos GM32887), verified in the Product_DB.csv catalogue. There is no 1:1 equivalence table validated by the manufacturer against other brands; alternatives from other manufacturers must always be checked piece by piece (tube connection type, thread, dimensions and compatible circumference) before any substitution in tenders or replacements. Consult the technical-commercial department of Cahnos to confirm exact compatibility with your equipment. Within the same Premium line, the following related references are identified: the 1-tube infant cuff (32886, same dimensions 7.5 x 26 cm), the 1-tube paediatric cuff (32888), the 1-tube neonate cuff (32817), the 2-tube adult cuff (32832) and the 2-tube adult large cuff (32835).
5. Selection tips and variants of interest
Always select the cuff size adjusted to the actual contour of the patient’s arm: an inappropriate cuff (too small or too large) distorts pressure readings. This infant size (13-19 cm) is indicated for babies and patients with thin arms; for paediatric patients choose the child size (19-27 cm, ref. 32888), for newborns the neonate size (9.5-13.5 cm, ref. 32817) and for adults the adult size (25.4-40.6 cm, ref. 32832 in 2-tube version). Verify that your blood pressure monitor or monitor uses a 2-tube connection before ordering this reference: dual-tube devices (Minor, Yton line, Roma 2T, Dallas, Big Ben, Empire, Dayton) require this variant; single-tube devices (Sirio, London, Boston, Roma 1T, Tokyo, Madrid, Ri-san, Precisa, Minimus) use the specific 1-tube version (ref. 32886). Periodically check the condition of the TPU bladder and Velcro and replace the cuff if there are leaks, deformations or wear to maintain the reliability of readings. For large orders you can request a quote: consult our technical-commercial team at Cahnos for terms, availability and volume orders.







Reviews