Description
1. Premium cuff for patients with a large arm circumference
The cuff for obese patients (ref. 32835) is the original replacement from the Premium range, designed to ensure reliable blood pressure measurements on adult arms with a large perimeter. Its construction in high-quality 210D nylon, with a TPU bladder and Velcro closure, offers a robust, hygienic and durable solution for medical practices, primary care, emergency departments, nursing units and home care.
Being a factory-made part, it retains the fit, comfort and inflation behaviour required by the original equipment, ensuring continuity of care without relying on repairs.
2. Technical Explanation
The cuff is the component of the sphygmomanometer that wraps around the arm and, when inflated, temporarily occludes the brachial artery during the blood pressure measurement. An inappropriate size or a deteriorated cuff distorts systolic and diastolic pressure values, so a correctly sized replacement in good condition is essential for measurement accuracy.
This model from the Premium range is manufactured from high-quality 210D nylon and incorporates a TPU bladder (blister) that distributes pressure evenly over the limb. Its Velcro closure system provides a firm but not excessive fit, and the assembly has passed durability tests of up to 10,000 cycles. The 2-tube configuration makes it compatible with the dual-connection aneroid sphygmomanometers in the range (Minor, Yton line, Roma 2T, Dallas, Big Ben, Empire, Dayton and similar).
3. Technical Specifications
| Characteristic | Detail |
|---|---|
| Product | Premium cuff for obese patients with bladder and 2 tubes |
| Material | High-quality 210D nylon |
| Bladder (blister) | TPU |
| Closure | Velcro |
| Colour | Dark grey |
| Model / size | Adult large |
| Cuff measurements | 63 x 17.5 cm |
| Arm circumference | 34.3 – 50.8 cm |
| Tube configuration | 2 tubes |
| Durability | Tested up to 10,000 cycles |
| Compatibility | Minor, Yton line, Roma 2T, Dallas, Big Ben, Empire, Dayton… |
Product data
| Manufacturer | GIMA |
|---|---|
| Manufacturer reference | 32835 |
| SKU Cahnos | GM32835 |
| Sales unit | 1 pc |
| Device type | Medical device (Medical device) |
| Device class | I |
| CND | C99 |
| GMDN | 34978 |
| EAN | 8023279328356 |
4. Equivalences and Cross-References
This cuff corresponds to the factory reference Ref. 32835 (SKU Cahnos GM32835), verified in the manufacturer’s catalogue. It is the 2-tube replacement in the obese-patient size indicated by the manufacturer for the dual-connection aneroid sphygmomanometers of the Minor, Yton line, Roma 2T, Dallas, Big Ben, Empire and Dayton family.
No equivalence table validated by the manufacturer has been found in reliable sources declaring this cuff as interchangeable 1:1 with cuffs from other blood pressure monitor brands. Cuffs from other manufacturers use their own connectors, tube lengths and gauges, so any replacement must be confirmed in advance with the technical-commercial department of Cahnos, verifying the 2-tube connection system, the connector diameter and the size of the specific device.
Within the 2-tube cuff family itself, the following related references with the same configuration are identified:
| Reference | Description | Related items |
|---|---|---|
| GM32915 (Ref. 32915) | Adult large cuff, 2 tubes, 16×63 cm, circumference 34.3 – 51 cm | Equivalent size variant in range |
| GM32914 (Ref. 32914) | One-piece cuff, 2 tubes, 14.5×54 cm, circumference 26 – 41 cm | Variant: standard size, same 2-tube connection |
5. Selection tips and variants of interest
Select the size according to the patient’s actual arm circumference (measured at the midpoint between the shoulder and the elbow): this cuff covers from 34.3 to 50.8 cm and is the appropriate choice for adult large-perimeter arms. A cuff that is too small causes overestimated readings, while one that is excessively loose underestimates them.
Check compatibility: this model is 2-tube and is designed for dual-connection aneroid sphygmomanometers (Minor, Yton line, Roma 2T, Dallas, Big Ben, Empire, Dayton). If your blood pressure monitor has a single tube or is from another manufacturer, it is not interchangeable without prior technical verification. For standard adult ranges (26-41 cm) it offers the 14.5×54 cm size (ref. GM32914) and for adult large size the 16×63 cm one (ref. GM32915).
Periodically inspect the condition of the Velcro, the TPU bladder and the connection fittings; replace the cuff at the first signs of wear, air leaks or loss of adhesion to maintain the reliability of measurements. In shared-use environments, have several cuffs available to rotate and facilitate cleaning between patients. For large orders you can request a quote: contact our technical-commercial department at Cahnos for terms and availability.





Reviews