Description
Premium cuff with TPU bladder and 2 tubes
The premium cuff from the range (ref. 32832) is the original high-resistance replacement for dual-tube sphygmomanometers. Its construction in high-quality 210D nylon, with an internal thermoplastic polyurethane (TPU) bladder and Velcro closure, makes it a robust, hygienic and durable solution for medical practices, primary care, emergency services, nursing units and home care. As a factory-made part, it retains the fit, comfort and inflation behaviour required by the original equipment, ensuring continuity of care for your fleet of blood pressure monitors.
Technical explanation
The cuff is the component of the sphygmomanometer that wraps around the arm and, when inflated, temporarily occludes the brachial artery to allow measurement of systolic and diastolic blood pressure. Its internal bladder must distribute pressure evenly and maintain airtightness so that the device correctly detects the oscillations of the arterial wall and calculates reliable values.
This model from the Premium range incorporates a TPU bladder that distributes pressure evenly over the limb, and the assembly has passed durability tests of up to 10,000 cycles. Its 2-tube configuration makes it compatible with dual-connection aneroid sphygmomanometers from the Minor, Yton line, Roma 2T, Dallas, Big Ben, Empire, Dayton families and similar. An inappropriate size or a worn cuff distorts pressure values; therefore, replacing the cuff with the original replacement of the correct size is essential for measurement accuracy.
Technical specifications
| Characteristic | Detail |
|---|---|
| Product | Premium cuff with TPU bladder and 2 tubes |
| Material | High-quality 210D nylon |
| Bladder (blister) | TPU (thermoplastic polyurethane) |
| Closure | Velcro |
| Colour | Dark grey |
| Model / size | Adult |
| Cuff measurements | 54 x 15 cm |
| Arm circumference | 25.4 – 40.6 cm |
| Tube configuration | 2 tubes |
| Durability | Tested up to 10,000 cycles |
| Compatibility | Minor, Yton line, Roma 2T, Dallas, Big Ben, Empire, Dayton… |
Product data
| Manufacturer | GIMA |
|---|---|
| Manufacturer reference | 32832 |
| Sales unit | 1 pc |
| Device type | Medical device (Medical device) |
| Device class | I |
| CND | C99 |
| GMDN | 34978 |
| EAN | 8023279328325 |
Equivalences and cross-references
This cuff corresponds to factory reference Ref. 32832 (SKU Cahnos GM32832), verified in the manufacturer’s catalogue. It is the 2-tube replacement in adult size indicated by the manufacturer for dual-connection aneroid sphygmomanometers from the Minor, Yton line, Roma 2T, Dallas, Big Ben, Empire and Dayton families.
No equivalence table validated by the manufacturer has been found in reliable sources that declares this cuff as 1:1 interchangeable with cuffs from other blood pressure monitor brands. Cuffs from other manufacturers use their own connectors, tube lengths and connection sizes, so any replacement must be confirmed in advance with the technical-commercial department of Cahnos, verifying the 2-tube connection system, the connector diameter and the size of the specific device.
Available references
| Reference | Description | Related items |
|---|---|---|
| GM32832 (Ref. 32832) | Premium cuff with TPU bladder, 2 tubes, 210D nylon, dark grey, adult, 54×15 cm, circumference 25.4 – 40.6 cm | This item |
| GM32835 (Ref. 32835) | Premium cuff with TPU bladder, 2 tubes, adult large, 63×17.5 cm, circumference 34.3 – 50.8 cm | Size variant of the same Premium line |
| GM32914 (Ref. 32914) | One-piece cuff, 2 tubes, latex-free nylon, adult, 14.5×54 cm, circumference 26 – 41 cm | Construction variant (integrated bladder) |
| GM32915 (Ref. 32915) | One-piece cuff, 2 tubes, latex-free nylon, adult large, 16×63 cm, circumference 34.3 – 51 cm | Size and construction variant |
| GM49707 (Ref. 49707) | Spare TPU bladder with 2 tubes, adult size, box of 5 units | Replacement for the internal bladder |
Selection tips and variants of interest
Select the size according to the actual arm circumference (measured at the midpoint between the shoulder and elbow): this adult cuff covers from 25.4 to 40.6 cm. A cuff that is too small causes overestimated readings and one that is too loose underestimates them, so correct size selection is crucial in clinical practice.
Check compatibility: this model is 2-tube and designed for dual-connection aneroid sphygmomanometers (Minor, Yton line, Roma 2T, Dallas, Big Ben, Empire, Dayton). If your blood pressure monitor is single-tube or from another manufacturer, it is not interchangeable without prior technical verification. For large arm circumferences (34.3 – 50.8 cm) it offers the adult large size from the same premium line (ref. GM32835) and for the internal bladder, the 2-tube TPU replacement in adult (ref. GM49707).
Maintenance: periodically inspect the condition of the Velcro, the TPU bladder and the connection fittings; replace the cuff if there are signs of wear, air leaks or loss of adhesion to maintain measurement reliability. In shared-use environments, have several cuffs available to rotate and facilitate cleaning between patients. For large orders you can request a quote: consult our technical-commercial department at Cahnos for terms and availability.