Description
1. Commercial Introduction
Maintain the accuracy of blood pressure readings in patients with large arm circumference with this nylon cuff for obese patients (Ref. 32841). Made of resistant nylon, latex-free, with TPU bladder and PVC tube, it is the original double-tube replacement designed for dual-connection aneroid sphygmomanometers such as Minor, Yton line, Roma 2T, Dallas, Big Ben, Empire and Dayton. A reliable, durable and correctly sized solution for practices, hospitals, primary care and measuring equipment maintenance services.
2. Technical explanation of the component
The cuff is the sphygmomanometer component that surrounds the patient’s arm to measure blood pressure non-invasively. When inflated, the internal bladder temporarily occludes the brachial artery and, when pressure is released in a controlled manner, allows detection of Korotkoff sounds (auscultatory method) or oscillations of the arterial wall (oscillometric method). For the measurement to be reliable, the bladder should cover approximately 40% of the arm circumference and the cuff must fit snugly, without folds or slack.
This model in adult large size, with dimensions of 62 x 17.5 cm, is indicated for arm circumferences of 34 to 51 cm, the recommended range for obese patients. The 2-tube configuration makes it compatible with the dual-connection aneroid sphygmomanometers in the indicated range; the nylon fabric, TPU bladder and PVC tube ensure tightness, durability and absence of latex.
3. Technical Specifications
Calibrated nylon cuff for obese patients, latex-free, with TPU bladder and PVC tube, in 2-tube configuration, black. Data verified in the manufacturer’s catalogue (Product_DB.csv).
| Characteristic | Specification |
|---|---|
| Product | Cuff for obese patient with bladder, 2 tubes |
| Model | Adult large (Adult large) |
| Colour | Black |
| Measurements | 62 x 17.5 cm |
| Arm circumference | 34 – 51 cm |
| Material | Nylon, latex-free |
| Internal bladder | TPU |
| Tubing | PVC, 2 tubes |
| Calibrated | Yes |
| Compatible with | Minor, Yton line, Roma 2T, Dallas, Big Ben, Empire, Dayton… |
| Sales unit | 1 pc |
Available references
| Reference | Description | Sales unit |
|---|---|---|
| 32841 | Cuff for obese patient, 2 tubes · 62 x 17.5 cm · Arm 34-51 cm · Black (SKU GM32841) | 1 pc |
Product data
| Manufacturer | GIMA |
|---|---|
| Manufacturer reference | 32841 |
| Sales unit | 1 pc |
| Device type | Medical device |
| Device class | I |
| CND | C99 |
| GMDN | 34978 |
| EAN | 8023279328417 |
4. Equivalences and Cross-References
This cuff is the manufacturer’s original replacement with reference 32841 (SKU Cahnos GM32841). No direct 1:1 equivalents with cuffs from other manufacturers are documented in reliable sources: each brand uses specific connection systems, number of tubes and bladder dimensions. Before replacing a part between brands, always confirm the compatibility of the connector and the number of tubes with your equipment or consult the technical-commercial department of Cahnos.
Within the 2-tube cuff family itself, related references with the same pneumatic configuration are identified:
| Reference | Description | Related items |
|---|---|---|
| GM32849 (Ref. 32849) | Cuff for obese patient, 2 tubes | Variant of the same 2-tube family |
| GM32915 (Ref. 32915) | Adult large cuff, 2 tubes, 16 x 63 cm, circumference 34.3 – 51 cm | Equivalent size variant in range |
| GM32914 (Ref. 32914) | One-piece cuff, 2 tubes, 14.5 x 54 cm, circumference 26 – 41 cm | Variant: standard size, same 2-tube connection |
| GM32835 (Ref. 32835) | Premium cuff for obese patient, 2 tubes, 63 x 17.5 cm | Premium version of the same range |
| GM32848 (Ref. 32848) | Cuff for obese patient, 1 tube, 62 x 17.5 cm, blue | 1-tube version for single connection |
5. Selection tips and variants of interest
Check that the patient’s arm circumference is within the range of 34 to 51 cm: an unsuitable cuff distorts blood pressure measurements.
Check that your blood pressure monitor or monitor uses a 2-tube connection; this model is designed for equipment such as Minor, Yton line, Roma 2T, Dallas, Big Ben, Empire and Dayton. If your equipment has a single tube, consider version GM32848, designed for Sirio, London, Boston, Roma 1T, Tokyo, Madrid, Ri-san, Precisa and Minimus.
Periodically check the condition of the TPU bladder, the tube and the closure: replace it in the event of leaks, deformation or wear to maintain the accuracy of readings.
If you manage a fleet of blood pressure monitors, keep this replacement in stock together with the rest of the sphygmomanometry family available in the Cahnos catalogue. As this product has no list price, request a quote from our technical-commercial team, who will advise you on supply conditions and volumes.







Reviews