3.182,50 €

The RIESTER RVS-100 multiparameter monitor (1960-RRXPE) is the bedside solution for rapid vital signs monitoring: it integrates clinical-grade non-invasive blood pressure (PNI/NIBP), Oximax SpO2 pulse oximetry and a printer in a device with an 8″ colour TFT touchscreen. With 3 measurement modes (monitoring, spot-check and triage), early warning scores EWS, NEWS and MEWS, memory for 5,000 measurements, LAN connectivity (HL7), Bluetooth with Riester thermometers and a lithium-ion battery with up to 11 hours of autonomy. Valid for neonatal, paediatric and adult patients. Original Riester reference 1960-RRXPE (ref. 33800). For large orders, you can request a quote.

Sales unit: 1 unidad
Minimum order for products shipped from Italy: 150,00 € excluding VAT (can be combined)

Delivery time: 15 days

International shipping. Import duties and taxes are payable by the recipient.

Reference
GM33800

Description

1. RIESTER RVS-100 multiparameter vital signs monitor (1960-RRXPE)

The RIESTER RVS-100 multiparameter monitor in its 1960-RRXPE configuration is the bedside solution designed by the German manufacturer Rudolf Riester for rapid and reliable vital signs monitoring in demanding healthcare environments. This version incorporates non-invasive blood pressure (NIBP), pulse oximetry (SpO2) and an integrated printer, making it a complete monitoring station for emergency departments, triage, consulting rooms, examination rooms and hospital wards. Its 8″ colour TFT touchscreen with intuitive interface and integrated help function allows simple operation and immediate reading of the parameters. Distributed in the healthcare channel under reference 33800, it is sold per unit. For large orders you can request a quote.

2. Technical description of the equipment

The RVS-100 combines the main non-invasive measurement techniques in a single device. Blood pressure is determined by an automatic oscillometric method of clinical quality, with adult, paediatric and neonatal modes, averaging function (2-5 readings) and double overpressure protection (hardware and software). Pulse oximetry uses Riester Oximax technology to measure oxygen saturation (SpO2) and pulse rate, with configurable averaging times (4, 8 or 16 seconds). The device offers 3 measurement modes (Monitor, Spot-check and Triage), programmable early warning scores EWS/NEWS/MEWS, 3-level visual and acoustic alarms in accordance with IEC 60601-1-8, internal memory for 5,000 measurements, LAN (HL7) connectivity for integration with the electronic health record, 4 USB ports, RJ11 nurse call output and a lithium-ion battery with up to 11 hours of autonomy.

3. Technical Specifications

Product data

Brand Riester
Manufacturer’s reference (Riester) 1960-RRXPE
Reference 33800
Sales unit 1 pc
Device type Medical device (Medical device)
Device class II B
CND Z12030280
EAN 4045396215368

Non-invasive blood pressure monitoring (NIBP)

Parameter Adult Paediatric Neonatal
Systolic pressure (SYS) 30-270 mmHg 30-235 mmHg 30-135 mmHg
Diastolic pressure (DIA) 10-220 mmHg 10-220 mmHg 10-110 mmHg
Mean arterial pressure (MAP) 20-235 mmHg 20-225 mmHg 20-125 mmHg
Specification Value
Measurement method Automatic oscillometric
Cuff pressure range 0-280 mmHg (resolution 1 mmHg)
Pressure accuracy Static ±3 mmHg; clinical ±5 mmHg (standard deviation 8 mmHg)
Pulse rate range 40-240 bpm (accuracy 1 bpm)
Initial inflation pressure Adult 160 mmHg / Paediatric 130 mmHg / Neonatal 75 mmHg
Overpressure protection Double (hardware and software): Adult 297 ± 3 mmHg / Paediatric 252 ± 3 mmHg / Neonatal 147 ± 3 mmHg
Alarm range SYS, DIA, MAP: 0-300 mmHg

Pulse oximetry (SpO2) and pulse rate

Parameter Value
SpO2 measurement range 0-100 % (resolution 1 %)
SpO2 accuracy ±2 % (70-100 %); ±3 % (40-69 %); not specified (0-39 %)
SpO2 alarm range 0-100 %
Averaging time 4 s, 8 s, 16 s
Pulse rate range 20-250 bpm (resolution 1 bpm)
Pulse rate accuracy ±1 % or ±1 bpm (whichever is greater)

Monitor, alarms, ports and connectivity

Specification Value
Display 8″ colour TFT touchscreen, high sensitivity, intuitive interface with integrated help function
Displayed parameters SYS, DIA, MAP, pulse, temperature, plethysmogram
Measurement modes Monitor, Spot-check, Triage
Early warning scores EWS, NEWS, MEWS and 5 customisable profiles
Alarms Visible LEDs (red, yellow, cyan), audible speaker, QRS tone; in accordance with IEC 60601-1-8 (45-85 dB at 1 m)
Ports 1 AC input, 1 RJ45 (100 BASE-TX, IEEE 802.3), 4 USB, 1 equipotential earth terminal, 1 RJ11 nurse call, DC output 15 V/1.2 A
Connectivity Standard LAN, HL7 standard (EHR/EMR), Bluetooth with Riester tymPRO and sensioPRO thermometers
Power supply 100-240 V AC, 50/60 Hz
Battery Rechargeable lithium-ion 10.8 V DC, 6,600 mAh; full charge in 6 h; approximate autonomy of 11 h (new and fully charged battery, with SpO2 and NIBP in automatic mode at 15 min intervals); low battery and charging indicators
Memory Internal for 5,000 measurements
Dimensions 303 x 110 x 230 mm
Weight 3,600 g (includes temperature module and printer)

Included accessories

Accessory Detail
Adult SpO2 sensor Included
SpO2 extension cable Included
NIBP extension tube Included
NIBP cuffs 2 cuffs with connector (adult and large adult)
User manual GB, IT (FR, DE, ES, RU on request)

4. Equivalences and Cross-References

SKU Cahnos Reference Riester reference Description
GM33800 33800 1960-RRXPE RVS-100 multiparameter monitor: NIBP + SpO2 + printer (this product)
GM33801 33801 1960-RRBPE RVS-100 multiparameter monitor: NIBP + SpO2 + predictive temperature + printer (variant with thermometer)
GM33805 33805 13301 RIESTER paediatric SpO2 sensor for RVS-100 (optional accessory)
GM33806 33806 13302 RIESTER adult SpO2 sensor for RVS-100 (replacement)
GM33810 33810 13317 RIESTER trolley with basket for RVS-100 monitor
GM33813 33813 129,006 Paediatric Velcro cuff 35.5 x 10 cm for RVS-100 (optional accessory)

No direct equivalent reference from other manufacturers has been confirmed for the Riester RVS-100 monitor: each manufacturer’s connectors and protocols are specific. As comparable references by category within the vital signs monitor catalogue of Cahnos, the multiparameter monitor PC-3000 (GM35134) and the handheld monitor PC-300 (GM35162) for spot-check measurement can be consulted. Before proposing any substitution in tenders, verify the specifications field by field with our technical-commercial department.

5. Selection tips and variants of interest

The 1960-RRXPE variant (GM33800, NIBP + SpO2 + printer) covers the essential parameters for triage and in-consultation monitoring; if integrated temperature measurement is also required, the 1960-RRBPE version (GM33801) adds the predictive oral thermometer with results in seconds. Select the cuff size according to the arm circumference: the device is supplied with adult and large adult cuffs, and accepts the optional paediatric Velcro cuff (ref. 129,006) and the adult and paediatric SpO2 sensors from the same family. Triage mode with EWS/NEWS/MEWS scales makes it especially suitable for emergency departments and triage bays, while LAN (HL7) connectivity and 5,000-measurement memory facilitate its integration into the centre’s electronic health record. To move it between points of care, the trolley with basket (ref. 13317) completes the equipment. For institutional orders, tenders or group purchasing organisations, contact the technical-commercial department of Cahnos.

Additional information

Manufacturer reference

1960-RRXPE

Model

RVS-100

Device type

Medical device (Medical device)

CND code

Z12030280

EAN

4045396215368

Parameters

NIBP + SpO2 + integrated printer

Display

8" colour TFT touchscreen, high sensitivity

Measurement modes

Monitor, Spot-check, Triage

NIBP method

Automatic oscillometric with averaging (2-5 readings) and neonatal mode

Systolic pressure range

Adult 30-270 / Paediatric 30-235 / Neonatal 30-135 mmHg

Diastolic pressure range

Adult 10-220 / Paediatric 10-220 / Neonatal 10-110 mmHg

Mean arterial pressure (MAP) range

Adult 20-235 / Paediatric 20-225 / Neonatal 20-125 mmHg

Precision NIBP

Static ±3 mmHg; clinical ±5 mmHg (standard deviation 8 mmHg)

SpO2 range

0-100 % (resolution 1 %)

Spo2 accuracy

±2 % (70-100 %); ±3 % (40-69 %)

SpO2 averaging time

4 s, 8 s, 16 s

Pulse rate range

20-250 bpm (resolution 1 bpm)

Early warning scores

EWS, NEWS, MEWS and 5 customisable profiles

Alarms

Visual (red, yellow, cyan LED) and 3-level acoustic alarms in accordance with IEC 60601-1-8

Connectivity

Standard LAN (HL7), Bluetooth, 4 USB ports, RJ11 nurse call

Power supply

100-240 V AC, 50/60 Hz

Battery

Rechargeable Li-ion 10.8 V DC, 6,600 mAh; approx. 11 h autonomy; 6 h charge

Memory

5,000 measurements

Dimensions

303 x 110 x 230 mm

Weight

3,600 g (includes temperature module and printer)

Included accessories

Adult SpO2 sensor, SpO2 extension cable, NIBP extension tube, 2 cuffs with connector (adult and large adult), GB/IT manual

Presentacion

Unit

Tipo dispositivo

Medical device

Clase sanitaria

II b

Documentation

📄 DatasheetEnglish PDF
📜 Declaration of conformityMultilingüe PDF
📜 CE certificateDownload PDF
📜 ISO 9001 / 13485 certificatesDownload PDF

Reviews

There are no reviews yet.

Be the first to review “RIESTER RVS-100 multiparameter vital signs monitor (1960-RRXPE) – NIBP, SpO2 and integrated printer | Ref. 33800”

Your email address will not be published. Required fields are marked *