PC-3000 multiparameter vital signs monitor (Ref. 35134) – ECG, SpO2, NIBP, 2-TEMP and RESP

807,50 €

Multiparameter vital signs monitor PC-3000 (Ref. 35134) with a 7″ high-resolution colour TFT screen and simultaneous display of 5 waveform channels. It continuously monitors standard parameters: ECG, RESP, SpO2, NIBP, dual temperature and pulse, with arrhythmia and ST-segment analysis. Includes adult/paediatric modes, protection against defibrillator and electrosurgical unit interference, visual and acoustic alarms, network capability and up to 12,000 data groups and 60 hours of ECG trace storage. Supplied with lithium-ion battery, NIBP cuff, adult SpO2 catheter, disposable electrodes and other accessories for start-up. For large orders you may request a quote.

Sales unit: 1 unidad
Minimum order for products shipped from Italy: 150,00 € excluding VAT (can be combined)

Delivery time: 15 days

International shipping. Import duties and taxes are payable by the recipient.

Reference
GM35134

Description

PC-3000 multiparameter vital signs monitor

The PC-3000 multiparameter monitor (Ref. 35134) is a vital signs surveillance device designed for healthcare settings requiring continuous and reliable patient monitoring: intensive care units, operating theatres, resuscitation rooms, emergency departments and intra-hospital transport. Its high-resolution colour TFT screen and its wide range of parameters make it a compact and versatile solution for the clinical monitoring of adult and paediatric patients.

Technical description of the equipment

The PC-3000 integrates in a single unit the monitoring of standard parameters: ECG (with arrhythmia and ST-segment analysis), respiration (RESP), oxygen saturation (SpO2), non-invasive blood pressure (NIBP), dual temperature channel (2-TEMP) and pulse (PR), with the possibility of displaying up to 7 simultaneous ECG waveforms. It features adult and paediatric measurement modes, protection against defibrillator and electrosurgical unit interference, visual and acoustic alarms, and network connectivity capability to integrate into centralised monitoring systems. Blood pressure measurement is performed using the automatic oscillometric method, with Manual, Auto and STAT modes, and the unit incorporates data storage and retrieval and trends for patient progress tracking.

Technical specifications

General characteristics

  • High-resolution 7” colour TFT screen with 5 waveform channel display.
  • Standard parameters: ECG, RESP, SpO2, NIBP, 2-TEMP, PR; arrhythmia and ST segment analysis.
  • Storage and retrieval of up to 12,000 parameter data groups and 60 hours of ECG tracing.
  • Graphical and tabular trends of 1,000 hours for all parameters.
  • Simultaneous display of 7 ECG waveform channels.
  • Protection against interference from defibrillators and electrosurgical units.
  • Adult/paediatric measurement modes.
  • Visual and audible alarms; network connectivity.
  • Transport handle with hooks for bed attachment.
  • Multilingual internal software: GB, IT, FR, ES, PT, PL, CZ, TR, CN.

NIBP monitoring

  • Measurement method: automatic oscillometric.
  • Initial cuff inflation pressure: adult mode < 180 mmHg; infant mode < 120 mmHg.
  • Overpressure protection limit: adult mode 300 mmHg; infant mode 240 mmHg.
  • Measurement modes: Manual, Auto and STAT.
  • Automatic measurement: interval from 1 to 240 minutes.
Parameter (mmHg) Adult mode Infant mode Accuracy
Systolic pressure 40 – 225 40 – 200 ± 10%
Diastolic pressure 20 – 215 20 – 165 ± 10%
Mean arterial pressure (MAP) 10 – 195 10 – 150 ± 10%

Temperature monitoring

  • Measurement range and accuracy: 25.0 – 45.0 °C, ± 0.2 °C.

SpO2 and pulse rate monitoring

  • Transducer: dual-wavelength LED.
  • SpO2 measurement range: 35% – 100%.
  • Low perfusion capability: 0.4% – 5%.
  • SpO2 display accuracy: 70% – 100% ± 3%.
  • Pulse measurement range: 30 – 250 lpm ± 2 lpm.

ECG monitoring

  • Heart rate measurement: ± 0.4 mVp – ± 5 mVp.
  • Heart rate display range: 20 – 250 lpm.
  • Display accuracy: ± 1% or ± 2 lpm (whichever is greater). Wide range of screen view options.
  • Heart rate alarm delay: 10 s.
  • Sensitivity selection: Auto, x1/2, x1, x2, x4 (tolerance: ± 5%).
  • Sweep speed: 12.5 mm/s, 25 mm/s, 50 mm/s (tolerance: ± 10%).
  • Common mode rejection ratio: ≥ 89 dB.
  • Frequency response: monitoring mode 0.5 – 40 Hz; diagnostic mode 0.05 – 75 Hz.

Respiration monitoring (RESP)

  • Measurement range and accuracy: 0 – 120 rpm, ± 5% or 2 rpm (whichever is greater).
  • RESP alarm range: 0 – 100 lpm ± 10%.

Other technical specifications

  • Power supply: 100 – 250 VAC, 50/60 Hz, < 80 VA.
  • Network port: serial/Net port.

Included accessories

  • 1 ECG cable
  • 1 adult SpO2 catheter
  • 1 AC adapter
  • 1 lithium-ion battery (Li-ion)
  • 1 NIBP cuff
  • 1 surface temperature transducer
  • 1 power cable
  • 10 disposable electrodes
  • User manual: IT, GB, FR

Product data

Manufacturer GIMA
Manufacturer reference 35134
Sales unit 1 unit
Device type Medical device
Device class II B
CND Z1203020201
GMDN 33586
EAN 8023279351347

Equivalences and cross-references

No direct equivalent reference from other manufacturers has been confirmed for the PC-3000 multiparameter monitor (Ref. 35134). As a similar reference in the same range of vital signs monitors marketed by Cahnos, the Riester RVS-100 multiparameter monitor can be consulted, also in the Vital Signs Monitors category, with SpO2, NIBP and temperature parameters. To equip the PC-3000, the system can be completed with standard consumables such as adult and paediatric blood pressure cuffs, SpO2 catheters and disposable ECG electrodes.

Selection tips and variants of interest

The PC-3000 is indicated for departments requiring continuous multiparameter monitoring in a compact and transportable desktop unit. Before selecting the model, assess the patient profile (adult or paediatric), the need for centralised network monitoring and the required accessories: NIBP cuffs in different sizes, spare SpO2 catheters, ECG cable and disposable electrodes. Confirm with our commercial team the configuration, optional accessories, language software and delivery times. For large orders you may request a quote: request your personalised offer without obligation.

Additional information

Brand

Creative Medical

Manufacturer reference

35134

EAN

8023279351347

CND code

Z1203020201

GMDN code

33586

Display

High-resolution 7'' colour TFT, 5 waveform channels

Parameters

ECG, RESP, SpO2, NIBP, 2-TEMP, PR; arrhythmia and ST segment analysis

Measurement modes

Adult / Paediatric

NIBP method

Automatic oscillometric; Manual, Auto and STAT modes

SpO2 range

35% – 100%

Spo2 accuracy

70% – 100% ± 3%

Heart rate range

20 – 250 lpm

Temperature range

25.0 – 45.0 °C (± 0.2 °C)

Data storage

12,000 parameter groups and 60 hours of ECG tracing; 1,000-hour trends

Power supply

100 – 250 VAC, 50/60 Hz, < 80 VA

Red

Serial/Net port

Software languages

GB, IT, FR, ES, PT, PL, CZ, TR, CN

Included accessories

ECG cable, adult SpO2 catheter, AC adapter, Li-ion battery, NIBP cuff, temperature transducer, power cable, 10 disposable electrodes, IT/GB/FR manual

Presentacion

Unit

Tipo dispositivo

Medical device

Clase sanitaria

II b

Alimentacion

Mains power, Rechargeable battery

Documentation

📄 DatasheetEnglish PDF
📎 Label / packagingLabel Box PDF · Label Prodotto PDF
📜 Declaration of conformityMultilingüe PDF
📜 CE certificateDownload PDF
📜 ISO 9001 / 13485 certificatesMultilingüe PDF

Reviews

There are no reviews yet.

Be the first to review “PC-3000 multiparameter vital signs monitor (Ref. 35134) – ECG, SpO2, NIBP, 2-TEMP and RESP”

Your email address will not be published. Required fields are marked *