Description
Adult SpO2 sensor compatible with Nellcor monitors
At Cahnos we offer you the reusable finger pulse oximetry SpO2 sensor for adult patients, manufactured as an OEM solution with Nellcor reference brand and under reference 35258. It is the ideal spare part for medical electronics services, ICU, emergency, operating theatre and hospitalisation departments that use monitoring equipment with Nellcor protocol and need to maintain continuous, stable and accurate measurement of oxygen saturation with a reliable and proven quality consumable.
Technical explanation
Pulse oximetry (SpO2) non-invasively measures the functional oxygen saturation of arterial haemoglobin and pulse rate by spectrophotometry: the sensor emits red and infrared light through the vascular bed of the finger and detects differential absorption according to the degree of blood oxygenation. The signal is transmitted to the monitor via the integrated 0.9 m cable, which connects directly to the SpO2 port of the equipment following the electrical scheme of the Nellcor protocol. Its forceps design (Adult Finger) allows quick, stable and ergonomic placement on adult patients, both for spot and continuous monitoring, ensuring reliable readings in demanding clinical environments.
Technical specifications
Reusable finger sensor for adults with integrated cable. The available references and product data registered by the manufacturer are detailed below.
Available references
| Reference | Cable length | Sales unit |
|---|---|---|
| GM35258 | 0.9 m cable | 1 pc |
| GM35259 | 3.0 m cable | 1 pc |
Product data
| Manufacturer | GIMA |
|---|---|
| Sales unit | 1 pc |
| Device type | Medical device (Medical device) |
| Device class | II B |
| CND | C900301 |
Sensor features
| Sensor type | Adult finger forceps (Adult Finger), reusable |
|---|---|
| Reference brand (OEM) | Nellcor |
| Cable length | 0.9 m (Ref. 35258) / 3.0 m (Ref. 35259) |
| Extension cable | Available – Ref. 35304 (optional) |
| Measured parameters | SpO2 and pulse rate |
| Manual included | Spanish, English, French and Italian (GB, FR, IT, ES) |
Verified compatibility
Artema: Diascope. Datascope (Mindray): Accutorr Plus, Expert, Passport, PM-50. Dräger: Cicero, Narkomed, Vitalert 1000. GE Medical: Corometrics 118, 120, 129, 188, 510, 556; Critikon 9710, 9720, Plus, Compact, Dinamap Select, MPS, Oxyshuttle, Pro 300/400; Eagle Series, Dash Series, Hellige Eagle 1000, 3000; Eagle SMK, SMU, SMV; SOLAR Series; TRAM Modular x50SL Series. Invivo Research: MI2 (Nellcor SpO2), Millennia 4500 Plus 2; Invivo/MDE Escort 100 OPT11A, Escort 300A, Escort II OPT30, Prism (Nellcor SpO2). Ivy Biomedical: 405A, 4050, 405P, 405T, Vital-Guard 450 CN. Mennen: Horizon XL (Nellcor SpO2), MR 1300, Mercury 1200. Nellcor: N100 (requires preamplifier cable), N180, N200 (requires preamplifier cable), N-20, NPB-75, NPB-290, NPB-295, N-390, N-395, N-3000, N6000. Nihon Kohden: BSM-1102 Life Scope EC, BSM-2304 iPro (Life Scope i), BSM-4102, 4112 Procyon LT (Life Scope P), BSM-4104, 4114 Procyon (Life Scope P), BSM-9510 Life Scope M (Nellcor SpO2), OGS-2000 PocketCare (Nellcor SpO2). Pace Tech: Vitalmax 800 Series (Nellcor SpO2). Philips: 78352C, 78354C, 78834C, M1020A, M1025B, M1205A, M1350B, M1722A/B, M1732A/B, M2475B, M2601A, M3000A.
Equivalences and cross-references
This sensor is marketed as an OEM product with Nellcor reference brand (Ref. 35258 and 35259) and is designed for the Nellcor protocol monitors listed in the specifications. There is no equivalence table validated by the manufacturer that authorises a 1:1 cross-reference with other brands: any replacement must verify the electrical scheme of the connector, the required cable length and the exact model of the installed monitor. In the Cahnos catalogue you can find other sensors in the same category, such as the available ones compatible with Nellcor protocol (e.g., GM33754 and GM33755) or the adult finger sensors for Datascope equipment (Ref. 35231), comparable by function and population but not interchangeable with each other without prior technical validation. Consult our technical-commercial department indicating the brand and model of your monitor to confirm exact compatibility.
Selection tips and variants of interest
Choose the cable length according to the equipment arrangement: Ref. GM35258 (0.9 m) is the standard option for monitors close to the patient, while Ref. GM35259 (3.0 m) offers greater reach for headboards, infusion stands or configurations where the monitor is further away. If you need to extend the connection distance, the manufacturer offers the extension cable Ref. 35304 as an optional accessory. As this is an adult finger forceps, make sure you select the sensor for the correct population (adult, paediatric or neonatal) according to the patient to be monitored. As a reusable sensor, follow the manufacturer’s cleaning instructions between patients to prolong its service life. For volume orders, service allocations or tenders, contact our technical-commercial team at Cahnos. For large orders you can request a quote.





Reviews
There are no reviews yet.