Description
1. Commercial Introduction
The 5-lead ECG patient cable (ref. 54406) is the reference spare part for the multiparameter vital signs monitor ref. 54405. It is an original accessory designed to keep your monitoring equipment fully operational: replacing the lead cable at the right time prevents signal loss, trace artefacts and interruptions to patient monitoring. A replacement solution intended for hospitals, intensive care units, emergency departments, outpatient clinics and medical transport services that rely on the monitoring range.
2. Technical explanation
The ECG patient cable is the element of the monitoring chain that transmits the heart’s electrical activity from the electrodes placed on the patient’s chest to the monitor. With a 5-lead configuration, it offers the standard leads for bedside monitoring, a more complete option than the 3-lead cable as it allows additional leads to be monitored without moving the electrodes. Its construction with shielded conductors protects the signal against electrical interference, and its connection terminals are prepared for single-use electrodes of the type commonly used in clinical monitoring. According to the manufacturer’s specifications, this spare cable requires the connection cable ref. 54407 for its link to the monitor 54405, so it should be considered as part of a complete set of accessories.
3. Technical Specifications
Main features of the 5-lead ECG cable (reference 54406), according to verified data from the manufacturer’s catalogue:
| Manufacturer | GIMA |
|---|---|
| Manufacturer reference | 54406 |
| Product type | 5-lead ECG patient cable (spare part) |
| Number of leads | 5 |
| Compatible equipment | Vital signs monitor ref. 54405 |
| Connection cable required | Ref. 54407 |
| Sales unit | 1 pc (1 piece) |
| Device type | Medical device |
| Device class | I |
| CND | Z1203020280 |
| EAN | 6941900602946 |
4. Equivalences and Cross-References
Ref. 54406 corresponds to the manufacturer’s official factory code for this 5-lead ECG spare cable for monitor 54405. There is no official equivalence table validated by the manufacturer that cross-references this reference with cables from other brands for the same equipment: ECG patient cables are specific to each monitor’s connector, so any replacement with a third-party accessory must be verified field by field (connector type, number of leads and compatibility with the monitor) against the equipment’s technical data sheet before use. Within the same family of accessories, the connection cable ref. 54407 is the indispensable complement for assembling this spare part, and the monitor ref. 54405 is the equipment for which the set is intended.
5. Selection tips and variants of interest
Check the number of leads on your equipment: this cable is 5-lead for monitor ref. 54405. Verify that you have the connection cable ref. 54407 to complete the link between the patient cable and the monitor; without it, the spare part installation will not be complete. For bedside monitoring, it is recommended to have a spare cable per monitoring station so as not to interrupt monitoring during replacement or cleaning. To complete the monitoring circuit, consider the disposable ECG electrodes, skin preparation gels and thermal recording paper from the Cahnos catalogue, always confirming compatibility with your installed base. For volume orders, complete sets or tenders, contact the technical-commercial department of Cahnos, which will confirm the exact reference and the formalised quotation.






Reviews
There are no reviews yet.