We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

4-lead ECG patient cable for vital signs monitor Ref. 54400 – Replacement (Ref. 54401) – Requires connection cable 54407

45,60 €

4-lead electrocardiography patient cable, original replacement (Ref. 54401) designed for the Ref. 54400 vital signs monitor. Spare part that restores ECG acquisition in emergency departments, hospital wards, outpatient clinics and intrahospital transport. Requires connection cable to monitor Ref. 54407 (not included). Class I medical device, sales unit: 1 unit.

Sales unit: 1 unidad
Minimum order for products shipped from Italy: 150,00 € excluding VAT (can be combined)

Delivery time: 15 days

International shipping. Import duties and taxes are payable by the recipient.

Reference
GM54401

Description

4-lead ECG cable: the replacement that keeps your Ref. 54400 monitor operational

This 4-lead ECG patient cable (Ref. 54401) is the replacement your facility needs to replace the electrocardiography wiring of the Ref. 54400 vital signs monitor. When a cable deteriorates through continued use, folds or frequent cleaning, signal quality degrades and artefacts appear on the trace; replacing it with the original part restores stable, reliable signal acquisition to the device, in accordance with the manufacturer’s specifications. An essential maintenance solution for emergency departments, hospital wards, ICUs, health centres and patient transport.

Technical explanation

The ECG patient cable connects the electrodes placed on the patient’s chest to the ECG input of the Ref. 54400 vital signs monitor. With a 4-lead configuration, it enables monitoring of cardiac electrical activity and the acquisition of the lead traces required for continuous patient monitoring, transmitting signals with minimal interference thanks to its shielding and insulation.

It is a replacement accessory (spare) designed specifically for the Ref. 54400 monitor. For connection to the device, the manufacturer states that it requires the additional connection cable Ref. 54407, which must be ordered separately if not already available. Always check the connector and lead system of your monitor before purchasing the replacement.

Technical specifications

Product data

Manufacturer GIMA
Sales unit 1 unit
Device type Medical device (medical device)
Device class I
CND Z1203020280
EAN 6941900601192

Spare part characteristics

Manufacturer reference 54401
Accessory type ECG patient cable, replacement (spare)
Number of leads 4 leads
Compatible equipment Vital signs monitor Ref. 54400
Connection cable required 54407 (not included)

Available references

SKU Cahnos Manufacturer reference Description
GM54401 54401 4-lead ECG patient cable for monitor 54400 (replacement)

Equivalences and cross-references

This cable corresponds to reference 54401 for the Ref. 54400 vital signs monitor (SKU Cahnos GM54401). There is no manufacturer-validated equivalence table cross-referencing this reference with cables from other manufacturers; ECG cables from other monitors are not interchangeable without prior technical validation, since each device uses specific connectors and lead assignments. Within the same family, the related references are the 54400 monitor (compatible device) and the 54407 connection cable (required to connect the replacement to the monitor). Consult our technical-commercial department before using this reference in tenders or replacing a cable from another supplier.

Selection tips and variants of interest

Confirm the exact model of your monitor: this cable is the replacement specified for the Ref. 54400 vital signs monitor. Check the device’s ECG input connector and verify whether you have the 54407 connection cable, essential for the operation of this reference. Periodically inspect the cabling for cuts, kinks or deterioration of the insulation, and replace the part if there are signs of poor trace quality. For institutional orders, maintenance contracts or volume requirements, contact our technical-commercial team, who will advise you on compatibility, supply conditions and a formal quotation.

Additional information

Manufacturer reference

54401

Product type

ECG patient cable (replacement)

Number of leads

4

Compatibility

Vital signs monitor ref. 54400

Connection cable required

54407 (not included)

Device type

Medical device (medical device)

CND code

Z1203020280

EAN

6941900601192

Manufacturer

GIMA S.p.A.

Presentacion

Unit

Tipo dispositivo

Medical device

Clase sanitaria

I

Documentation

📄 DatasheetEnglish PDF
📜 Declaration of conformityEnglish PDF
📜 ISO 9001 / 13485 certificatesMultilingüe PDF

Reviews

There are no reviews yet.

Be the first to review “4-lead ECG patient cable for vital signs monitor Ref. 54400 – Replacement (Ref. 54401) – Requires connection cable 54407”

Your email address will not be published. Required fields are marked *