We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Tympanometer Maico touchTymp RaceCar – Impedance Analyser with Paediatric Animation, 10.4″ Touchscreen and Integrated Printer | Ref. ABM-TOUCHTYMP-RACECAR

Price on request

Touch tympanometer MAICO touchTymp RaceCar designed for middle ear screening in paediatrics: the full-colour car race animation keeps the child focused during tympanometry and acoustic reflex detection, reducing repetitions and test times. Results in 3-5 seconds, ergonomic probe with luminous progress bar, fully customisable 10.4″ touchscreen, integrated printer and data transmission to PC via the optional MAICO Sessions software, compatible with OtoAccess® and Noah databases.

International shipping. Import duties and taxes are payable by the recipient.

Reference
ABM-TOUCHTYMP-RACECAR
Brand
Maico

Description

1. Paediatric tympanometry, now fun and efficient

The MAICO touchTymp RaceCar tympanometer (Ref. ABM-TOUCHTYMP-RACECAR) turns middle ear examination into an engaging experience for young children: the moment tympanometry or acoustic reflex testing begins, an exciting full-colour car race starts on screen, keeping the child attentive, seated and still. With the patient focused, the probe seal is broken far less often, resulting in fewer repeats, test results in seconds and a smoother workflow for the ENT, audiology or primary care specialist.

2. Technical explanation of the equipment

The touchTymp RaceCar is an acoustic impedance analyser from the MAICO touch series that performs tympanometry and acoustic reflex tests (ipsilateral as standard, contralateral optional) with a 226 Hz probe tone and an optional 1 kHz high-frequency tone for newborns. Its 10.4-inch touchscreen allows parameters to be changed and tests to be switched with just three taps. The ergonomic probe incorporates a light bar that provides real-time feedback on test progress, and indicator lights that show the ear being examined and the result. Reports are printed automatically when the probe is placed in its holder, and transfer to PC is via the optional MAICO Sessions software, which can be integrated with OtoAccess® and Noah patient databases. The RaceCar animation is included as standard across the entire touchTymp range.

3. Technical Specifications

Characteristic Specification
Model / Family MAICO touchTymp RaceCar (touchTymp touch series)
Reference (SKU) ABM-TOUCHTYMP-RACECAR
Set type Tympanometer / acoustic impedance analyser for screening
Display 10.4″ colour touchscreen
Probe tone 226 Hz · 85 dB SPL (± 1.5 dB); optional 1 kHz · 69 dB SPL (± 1.5 dB)
Pressure range -600 to +400 daPa (accuracy ± 5% or ± 10 daPa)
Volume range 0.0 to 6.0 ml compensated (± 5% or 0.1 ml)
Compliance range 0.1 to 8.0 ml at 226 Hz; 0.1 to 15.0 mmho at 1 kHz (option)
Acoustic reflexes 500 Hz, 1 kHz, 2 kHz, 4 kHz ipsilateral (contralateral optional); automatic or fixed level; ipsilateral with AGC
Test time 3-5 seconds
Paediatric animation RaceCar (car race) included as standard
Catheter Ergonomic with light bar for progress and ear/result indicators
Printer Integrated, automatic printing when the probe is placed in the holder
Connectivity / software Data transfer to PC; optional MAICO Sessions software (OtoAccess® and Noah)
Scope of use ENT, audiology, paediatrics, primary care and hearing screening services

4. Equivalences and Cross-References

The reference ABM-TOUCHTYMP-RACECAR corresponds to the distribution code of the MAICO touchTymp device with the RaceCar animation included. Within the manufacturer’s own family, the touchTymp is marketed in the MI 24 (screening tympanometer), MI 26 and MI 36 (tympanometer with audiometry) and MI 34 (ENT diagnostic) variants, all of which include the RaceCar animation as standard according to the manufacturer; reference 136910, corresponding to the touchTymp MI 24 in standard configuration without the RaceCar animation and without printer, has been verified in authorised distribution and is not interchangeable 1:1 with the device described here because it lacks these elements.

There is no manufacturer-validated equivalence table cross-referencing this reference with third-party codes; consult the technical department before use in tenders. At category level, tympanometers with touchscreen and acoustic reflexes from manufacturers such as Interacoustics (Titan series), Inventis, GN Otometrics / Madsen, Grason-Stadler (GSI) or Amplivox cover the same clinical indication of middle ear screening; before any substitution, the probe tone frequency and level, pressure range, reflex frequencies (ipsi/contralateral), presence of printer and data management software must be verified field by field.

5. Selection tips and variants of interest

The touchTymp RaceCar is the recommended option when the volume of paediatric patients requires reducing time per examination and avoiding repeats: the animation keeps the child’s attention and minimises probe seal losses. If your service also performs air and bone conduction audiometry, consider the combined touchTymp MI 26 or MI 36 models from the same family; if you need 678 and 800 Hz probe tones and reflex decay or Eustachian tube function (ETF) tests, the MI 34 is the most complete diagnostic variant. For network integration in the centre, activate the MAICO Sessions software with connection to OtoAccess® or Noah and request the contralateral probe and 1 kHz tone options from the distributor. For institutional orders, tenders or supply contracts, contact the technical-commercial department of Cahnos to confirm the exact configuration and obtain a formal quotation under B2B conditions.

Additional information

Brand

MAICO Diagnostics

Reference

ABM-TOUCHTYMP-RACECAR

Product type

Tympanometer / acoustic impedance analyser

Display

10.4-inch colour touchscreen

Catheter frequency

226 Hz (optional 1 kHz high frequency)

Pressure range

-600 to +400 daPa

Compliance range

0.1 to 8.0 ml (226 Hz); 0.1 to 15.0 mmho (1 kHz)

Volume range

0.0 to 6.0 ml

Acoustic reflexes

500 Hz, 1 kHz, 2 kHz and 4 kHz ipsilateral (contralateral optional)

Test time

3-5 seconds

Paediatric animation

RaceCar included as standard

Printer

Integrated with automatic printing

Connectivity

USB to PC; MAICO Sessions software with OtoAccess and Noah

Use

Middle ear screening in paediatric and adult patients

Reviews

There are no reviews yet.

Be the first to review “Tympanometer Maico touchTymp RaceCar – Impedance Analyser with Paediatric Animation, 10.4″ Touchscreen and Integrated Printer | Ref. ABM-TOUCHTYMP-RACECAR”