Description
1. The first touchscreen tympanometer in the MAICO series
The Maico TouchTymp MI 24 represents a new generation of intuitive impedance testing. Designed for middle ear screening, it allows testing of children and adults with results in a matter of seconds, without compromising diagnostic reliability. Its fully touchscreen interface makes operation extremely simple: the large colour screen and its innovative icon structure allow parameters to be changed with just three taps, improving the daily workflow of ENT specialists, hearing aid acousticians and primary care professionals.
2. Technical explanation of the equipment
The TouchTymp MI 24 is an acoustic impedance analyser that combines tympanometry and acoustic reflex testing in a single compact desktop device. It uses a 226 Hz probe tone with an optional 1 kHz high-frequency tone, especially recommended for obtaining reliable results in newborns. The available acoustic reflex frequencies are 500 Hz, 1 kHz, 2 kHz and 4 kHz, with ipsilateral stimulation as standard and contralateral optional.
The test is patient-centred: the ergonomic and innovative probe incorporates a light bar that provides real-time information on the progress of the measurement, while other light indicators show which ear is being examined and what the result is. Reports are printed automatically when the probe is placed in its holder thanks to the integrated printer. Data transfer to a PC is carried out via the optional MAICO Sessions software, which connects to the OtoAccess® and Noah patient databases for simple, centralised management.
3. Technical Specifications
| Characteristic | Specification |
|---|---|
| Brand / Model | MAICO TouchTymp MI 24 (touchTymp touchscreen series) |
| Reference (SKU) | ABM-TIMPANOMETRO-TOUCHTYMP-MI24 |
| Set type | Tympanometer / acoustic impedance analyser for middle ear screening |
| Display | 10.4″ colour touchscreen (26.4 cm), high resolution |
| Probe tone | 226 Hz · 85 dB SPL (± 1.5 dB); optional 1 kHz · 69 dB SPL (± 1.5 dB) |
| Pressure range | −600 to +400 daPa (accuracy ± 5% or ± 10 daPa) |
| Volume range | 0.0 to 6.0 ml compensated (± 5% or 0.1 ml) |
| Compliance range | 0.1 to 8.0 ml at 226 Hz; 0.1 to 15.0 mmho at 1 kHz (option) |
| Acoustic reflex frequencies | 500 Hz, 1 kHz, 2 kHz, 4 kHz (ipsilateral as standard / contralateral optional); automatic or fixed level; ipsilateral with AGC |
| Test time | 3–5 seconds |
| Catheter | Ergonomic, with a progress light bar and ear and result indicators |
| Printer | Integrated; automatic printing when the probe is placed in the holder |
| Connectivity / software | Data transfer to PC; optional MAICO Sessions software (OtoAccess® and Noah) |
| Configurability | Customisable to meet the individual needs of the professional |
| Scope of use | ENT, audiology, paediatrics, primary care and hearing screening services |
4. Equivalences and Cross-References
The reference ABM-TIMPANOMETRO-TOUCHTYMP-MI24 corresponds to the Cahnos distribution code for the MAICO TouchTymp MI 24 tympanometer. There is no manufacturer-validated equivalence table cross-referencing this reference with third-party codes; consult the technical department before using it in a tender. Within the MAICO family itself, the paediatric RaceCar animation (full-colour car race) is included as standard in the touchTymp line. It has been verified in authorised distribution that reference 136910 corresponds to the TouchTymp MI 24 in standard configuration without RaceCar animation and without printer, which is not interchangeable 1:1 with the equipment described here because it lacks these elements.
At category level, tympanometers with touchscreen and acoustic reflexes from manufacturers such as Interacoustics (Titan series), Inventis, GN Otometrics / Madsen, Grason-Stadler (GSI) or Amplivox cover the same clinical indication for middle ear screening. Before any replacement, the frequency and level of the probe tone, the pressure range, the reflex frequencies (ipsi/contralateral), the presence of a printer and the data management software must be verified field by field.
5. Selection tips and variants of interest
The TouchTymp MI 24 is the recommended option as a screening tympanometer when speed, desktop portability and ease of use are prioritised: results in 3–5 seconds, parameter customisation and less stress for the patient thanks to the probe with light and the standard RaceCar animation. If your department also requires audiometry, consider the combined models in the same family: TouchTymp MI 26 (tympanometry + optional air and bone conduction audiometry) and TouchTymp MI 36 (tympanometry + air and bone conduction audiometry). For advanced ENT diagnostics, the TouchTymp MI 34 adds 678 Hz and 800 Hz probe tones, reflex decay testing and Eustachian tube function (ETF) for intact and perforated eardrums.
For network integration in the centre, activate the MAICO Sessions software with connection to OtoAccess® or Noah and request from your distributor the contralateral probe and 1 kHz high-frequency tone options. For institutional orders, tenders or supply contracts, contact the technical-commercial department of Cahnos to confirm the exact configuration and obtain a formalised quotation under B2B conditions.