Description
1. Eco-friendly gallium thermometer with magnifying glass and shaker
The eco-friendly gallium thermometer (ref. 25568) is the safe, accurate and functional alternative to classic mercury thermometers, completely eliminating their toxicity without compromising the traditional analogue reading behaviour. Its column is filled with a gallium alloy, a non-toxic metal with thermal behaviour equivalent to mercury, thus maintaining the classic measurement reliability with the safety required in today’s environments: homes, pharmacies, parapharmacies, clinics, care homes and healthcare centres. Each unit incorporates two highly useful clinical aids: a shaker to reset the column after each reading and a magnifying glass that facilitates reading the scale, especially indicated for elderly patients or those with reduced vision.
2. Technical explanation of the equipment
This thermometer works on the classic principle of thermal expansion: the gallium alloy contained in the bulb expands on contact with the body and rises up the graduated capillary until it stabilises at the patient’s actual temperature. When the thermometer is removed, the reading remains fixed in the column; to reset it, the alloy must be brought down below the working temperature (usually below 36 °C). This is exactly the function of the included shaker: holding the thermometer by the end opposite the bulb and performing a firm, controlled shaking motion, the gallium column descends and the instrument is ready for a new use. The built-in magnifying glass allows clear reading of the capillary graduation, a very useful reading aid in clinical thermometry. Compared with mercury thermometers, it offers decisive advantages: total absence of mercury (safety against breakage and compliance with regulations restricting this metal), robust glass structure with clear graduation and functional behaviour equivalent to the classic thermometer. It is easy to handle and requires no batteries or electronic maintenance.
3. Technical Specifications
Features verified against the manufacturer’s official catalogue (Product_DB.csv).
Product data
| Manufacturer | GIMA |
|---|---|
| Manufacturer reference | 25568 |
| Reference Cahnos (SKU) | GM25568 |
| Sales unit | 1 pc |
| Device type | Medical device |
| Device class | I M |
| CND | V03010199 |
| EAN | 6948647010690 |
Main characteristics
| Characteristic | Description |
|---|---|
| Measurement technology | Gallium alloy instead of mercury (mercury-free) |
| Reading type | Analogue, gallium column |
| Structure | Glass |
| Included accessories | Shaker to facilitate the descent of the gallium column after each use and magnifying glass to facilitate reading |
| Presentation | Individual box (1 unit) |
| Safety | Mercury-free: safe, accurate and functional |
| Documentation | Box and multilingual instructions: GB, FR, IT, ES, PT, DE, PL, NL, SE, HU, RO, SK, HR, SI, BG, GR and Arabic |
4. Equivalences and Cross-References
This product corresponds to the original reference number 25568. No validated 1:1 equivalence table with third-party manufacturers is available for this model; any substitution must be verified field by field against the official datasheet. Within the Cahnos catalogue, it is related to the manufacturer’s eco-friendly thermometry range:
| Reference | Product | Related items |
|---|---|---|
| 25586 (GM25586) | Eco-friendly gallium thermometer with shaker, unit (EAN 8023279255867) | Same technology, without reading magnifying glass |
| 25589 (GM25589) | Eco-friendly thermometer display with shaker, 24 units | Same thermometer in display box |
| 25587 (GM25587) | Shaker for eco-friendly thermometer, box of 24 units. | Compatible replacement accessory |
| 25569 (GM25569) | Shaker with magnifying glass for eco-friendly thermometer, box of 24 units | Alternative accessory with reading lens |
5. Selection tips and variants of interest
Choose the eco-friendly gallium thermometer with magnifying glass and shaker when you need a measuring instrument with the classic behaviour of mercury thermometers but without their toxicity, and especially consider this version when reading support is a priority (elderly patients, low vision or reading in low-light conditions). For correct use, shake the thermometer with the shaker until the gallium column drops below 36 °C, place the bulb in contact with the measurement area and wait for the column to stabilise before reading with the aid of the magnifying glass. If your centre does not require a magnifying lens, the eco-friendly thermometer with shaker (ref. 25586) is available; for counter sales and continuous replenishment, the 24-unit display (ref. 25589); and to replace lost shakers, the box of 24 shakers (ref. 25587) or the shaker with magnifying glass (ref. 25569). Always handle the instrument gently: although its contents are safe compared with mercury thermometers, the structure is glass and must be protected from knocks. For institutional orders, supply contracts or substitution queries, contact the technical-commercial team at Cahnos:. For large orders you can request a quote.







Reviews
There are no reviews yet.