Description
1. Introduction
The reusable neonatal type Y SpO2 catheter (ref. 35315) is the pulse oximetry accessory indicated for non-invasive monitoring of oxygen saturation and pulse rate in newborn patients. Thanks to its type Y design, it adapts comfortably to the neonate’s foot or hand, ensuring a stable hold and reliable reading during continuous monitoring in neonatology, paediatrics, delivery rooms and critical care units. It is an original, reusable component designed to work in combination with the brand’s pulse oximeters.
2. Technical Explanation
Pulse oximetry is a non-invasive optical technique that measures the oxygen saturation of haemoglobin through the differential absorption of red and infrared light across the capillary bed. The catheter incorporates the emitter and photodetector in a single flexible assembly that surrounds the neonate’s measurement area, transmitting the signal to the monitor via the connection cable. This type D configuration catheter with 0.9 m cable and type Y connector is specifically designed for the neonatal population, whose limb size requires small, highly flexible sensors to avoid compression and movement artefacts. It is a reusable device: after each use it must be cleaned following the manufacturer’s instructions to ensure hygiene between patients and extend its service life.
3. Technical Specifications
| Manufacturer | GIMA |
|---|---|
| Manufacturer reference | 35315 |
| Catheter type | Reusable SpO2 catheter, type Y, neonatal |
| Configuration / cable type | Type D, length 0.9 m |
| Population | Neonates |
| Compatibility | Pulse oximeters K12, K15 (requires cable ref. 35318) and Oxy 110 (optional) |
| Sales unit | 1 pc |
| Device type | Medical device |
| Device class | II A |
| CND | C900301 |
| GMDN | 36087 |
| EAN | 8023279353150 |
4. Equivalences and Cross-References
This catheter corresponds to reference 35315 and is verified in the manufacturer’s catalogue (Product_DB base). For the K12 and K15 pulse oximeters, the connection cable with reference 35318 is required; for the Oxy 110 model, the catheter is offered as an optional accessory. No 1:1 equivalence with catheters from other manufacturers has been verified in reliable sources: before replacing this reference with a sensor from another brand in tenders or equipment fleets, consult our technical-commercial department to validate the compatibility of the connector and the pulse oximetry system.
5. Selection tips and variants of interest
Always select the catheter according to the population and the monitor: for neonates, this type Y catheter (ref. 35315) is the indicated one, while for paediatric or adult patients, the specific catheter for each range is recommended. Verify the cable reference 35318 when configuring the K12 and K15 equipment, as well as the most appropriate cable length for your monitoring station. As it is a reusable sensor, establish a cleaning and periodic inspection protocol for the connector and cable to maintain signal quality. For institutional orders, volume purchases or compatibility with other monitoring models, contact Cahnos and we will advise you on the complete configuration of accessories.