Description
1. Commercial Introduction
At Cahnos we offer you the SpO2 pulse oximetry sensor reusable for adult patients as an original replacement for the pulse oximeter Ref. 35060 (Ref. 35061). It is the ideal spare part to restore blood oxygen saturation measurement when the original sensor deteriorates or to have a second catheter that allows alternating between patients without interrupting care activity. A reliable and proven quality solution for clinics, primary care, emergency departments, hospitalisation and diagnostic centres.
2. Technical explanation
Pulse oximetry is a non-invasive optical technique that estimates the functional oxygen saturation of arterial haemoglobin (SpO2) and pulse rate by spectrophotometry: the sensor emits light at two wavelengths (red and infrared) through the vascular bed of the finger and a photodetector quantifies the differential absorption according to the degree of blood oxygenation. This reusable adult catheter integrates the emitter and photodetector in a single element that is placed comfortably and stably on the patient’s finger; the captured signal is transmitted to the pulse oximeter Ref. 35060, which processes it and displays the values on screen. As it is a reusable sensor, it must be cleaned between patients following the manufacturer’s instructions, which reduces the cost per use compared with disposable catheters.
3. Technical Specifications
| Manufacturer | GIMA |
|---|---|
| Manufacturer reference | 35061 |
| Compatible equipment | Pulse oximeter Ref. 35060 |
| Sensor type | Reusable adult SpO2 sensor (replacement / spare) |
| Patient population | Adult |
| Sales unit | 1 pc |
| Device type | Medical device |
| Device class | II B |
| CND | Z12030280 |
| EAN | 6944904005904 |
| Available references | |
|---|---|
| Reference | 35061 |
| Compatible equipment | 35060 |
| Sales unit | 1 pc |
4. Equivalences and Cross-References
Reference 35061 is the original replacement for the pulse oximeter 35060. No equivalence table validated by the manufacturer has been found in reliable sources confirming the 1:1 interchangeability of this catheter with SpO2 sensors from other manufacturers, since compatibility depends on the type of connector and the electronic protocol of each device; it is always recommended to verify the connector and sensor specifications with our technical department before considering replacement with a catheter from another brand. Within the same family there are comparable reusable adult SpO2 catheters by category and population, such as references 35049 (replacement for 35048), 35165 (replacement for PC-300) and 32903, among others; they are similar in functionality but not interchangeable with each other without confirming compatibility with the installed equipment.
5. Selection tips and variants of interest
Confirm that your pulse oximeter corresponds to model 35060 before placing the order and verify the type of connector required by your equipment. As it is a reusable sensor, follow the manufacturer’s cleaning and disinfection instructions between patients and periodically check the cable and contact area to avoid erroneous readings. It is recommended to have a spare unit for each pulse oximeter in use to minimise downtime; if your service also attends to paediatric patients, consult the catalogue at Cahnos for the reusable paediatric SpO2 catheters from the same family. For large orders you can request a quote: contact our technical-commercial team to confirm compatibility, availability and B2B supply conditions.




Reviews
There are no reviews yet.