Description
1. Commercial Introduction
The paediatric pulse oximetry SpO2 catheter (ref. 35328) is the optional accessory your department needs to monitor oxygen saturation and pulse rate in paediatric patients with the vital signs monitor Ref. 35145. Manufactured as an original replacement and extension of the 35145 family, this child-size catheter allows monitoring to be extended to the paediatric population without having to replace the main equipment, maintaining the accuracy and reliability typical of the Italian manufacturer’s original accessories.
2. Technical explanation of the equipment
Pulse oximetry is a non-invasive optical technique that measures the oxygen saturation of haemoglobin through the differential absorption of red and infrared light across the capillary bed. This paediatric catheter connects the Ref. 35145 monitor to the infant patient and transmits the plethysmographic signal that the monitor converts into SpO2 and pulse rate values. Being a paediatric-size catheter, it offers a safer and more precise fit in young patients, reducing the risk of motion artefacts and poor fixation. For connection, the adapter or cable 35324 indicated by the manufacturer is required, and its use is guaranteed from serial number J3300SE01687 of the monitor.
3. Technical Specifications
The product’s technical data are detailed below, cross-checked against the manufacturer’s official catalogue:
| Manufacturer | GIMA |
|---|---|
| Manufacturer reference | 35328 (SKU Cahnos: GM35328) |
| Sales unit | 1 pc |
| Device type | Medical device |
| Device class | II A |
| GMDN | 36087 |
| EAN | 6941900600362 |
| Target population | Paediatric |
| Compatible equipment | Vital signs monitor Ref. 35145 |
| Required accessory | Adapter/cable 35324 (required for use of the catheter) |
| Monitor validity | From serial number J3300SE01687 |
4. Equivalences and Cross-References
This catheter is part of the family of original accessories for the Ref. 35145 monitor. There is no official equivalence table validated by the manufacturer that cross-references this reference with catheters from other manufacturers, so it must not be replaced by a third-party catheter without first verifying the compatibility of the connector and the monitor’s electronics.
- 35145: vital signs monitor to which this catheter is connected.
- 35324: connection adapter/cable required to use the paediatric catheter with the monitor.
5. Selection tips and variants of interest
Verify that your Ref. 35145 monitor corresponds to serial number J3300SE01687 or higher before purchasing this catheter. Confirm the availability of adapter 35324, as it is essential for the accessory to function. For departments with a mixed population, complete the equipment with catheters of other sizes from the 35145 monitor family (adult and neonatal, depending on catalogue availability) and always select the appropriate catheter for the patient group to ensure a quality signal. For institutional orders, supply contracts or compatibility queries, contact our technical-commercial department at Cahnos.