Description
1. Commercial presentation
The OXY-4 finger pulse oximeter (ref. 35091, blue) is a portable medical device designed to non-invasively check in seconds the arterial haemoglobin oxygen saturation (SpO2), pulse rate and perfusion index. Its compact and ultra-lightweight clip format (66 x 36 x 33 mm) makes it ideal for medical consultations, emergency and urgent care services, primary care, social-health centres, home care, physiotherapy and sports medicine.
For large orders you can request a quote: contact the technical-commercial team at Cahnos to confirm availability, conditions for fleets and equipment projects.
2. Technical explanation of the equipment
Pulse oximetry is a non-invasive optical technique that measures the functional oxygen saturation of arterial haemoglobin. The OXY-4 sensor emits light at two wavelengths (red and infrared) through the nail bed; a photodetector located on the opposite side of the finger quantifies the light absorbed by the tissues. The pulsatile component of the signal, generated by the arterial beat, allows calculation of the percentage of saturated haemoglobin (SpO2) and pulse rate.
The device simultaneously displays SpO2, pulse rate (PR), perfusion index (PI), plethysmogram (pulse wave) and pulse bar on a dual-colour screen adjustable in 4 directions, making it easy to read for both the professional and the patient. It incorporates automatic on/off, audible and visible alarm, low battery indication and alarm, water ingress protection and drop resistance. It is designed for spot screening measurements; not for continuous patient monitoring.
3. Technical Specifications
Product data
| Field | Value |
|---|---|
| Manufacturer | GIMA |
| Sales unit | 1 pc |
| Device type | Medical device (Medical device) |
| Device class | II A |
| CND | Z1203020408 |
| GMDN | 45607 |
Technical features
| Parameter | Specification |
|---|---|
| Model | OXY-4 |
| Manufacturer references | 35091 (blue), 35092 (orange) |
| Measured parameters | SpO2, pulse rate (PR) and perfusion index (PI) |
| SpO2 measurement range | 35 – 99 % |
| Pulse rate range | 30 – 240 bpm |
| Display | Dual colour: SpO2, PR, PI, plethysmogram and pulse bar; adjustable in 4 directions |
| On/off | Automatic |
| Power supply | 2 AAA alkaline batteries |
| Battery life | More than 30 hours of continuous operation |
| Alarms | Audible and visible alarm; battery voltage indication and low battery alarm |
| Protection | Water ingress protection and drop resistance |
| Measurements | 66 x 36 x 33 mm |
| Manual | In 8 languages: GB, FR, IT, DE, ES, PT, GR, PL |
Available references
| Reference | Colour | Sales unit |
|---|---|---|
| GM35091 | blue | 1 pc |
| GM35092 | orange | 1 pc |
4. Equivalences and Cross-References
There is no official equivalence table validated by the manufacturer that cross-references the OXY-4 with specific codes from other brands on a 1:1 interchangeable basis. The following references are functional comparisons by category (same clinical indication: spot measurement of SpO2, pulse and perfusion index in a finger pulse oximeter) and must be validated field by field against the technical data sheet of each manufacturer before any substitution in a tender:
| Family / Model | Reference | Equivalence level |
|---|---|---|
| ME5 finger pulse oximeter (medical ECONET) | 40.22-5206 | Comparable by category (not interchangeable 1:1) |
| ME7 finger pulse oximeter (medical ECONET) | 40.21-5207 | Comparable by category (not interchangeable 1:1) |
| ME10 finger pulse oximeter (medical ECONET, with alarm) | 40.22-5205 | Comparable by category (not interchangeable 1:1) |
| PULOX PO-200 digital pulse oximeter | 713 | Comparable by category (not interchangeable 1:1) |
Consult with the technical department of Cahnos before using this reference as a substitute in specifications or public tenders.
5. Selection tips and variants of interest
Choose the OXY-4 in blue (GM35091) or orange (GM35092) according to the visual identification you prefer for your service, as both share the same technical features and are supplied in a sales unit of 1 pc.
- Intended use: spot screening measurements in consultations, emergencies, home care and sports monitoring; does not replace continuous monitoring or clinical judgement.
- Display and perfusion index (PI): the 4-direction adjustable reading and the plethysmogram allow verification of signal quality; the PI helps assess perfusion at the measurement point.
- Maintenance: use quality AAA alkaline batteries, respect polarity, replace the batteries when the low battery warning appears and clean the sensor pads between patients.
- Catalogue variants: for similar needs, Cahnos offers finger pulse oximeters from other ranges (ME5, ME7, ME10 and PULOX) and handheld monitors from the PalmCare Pro family for advanced monitoring.
For volume orders or equipment projects, request a quote from the technical-commercial team at Cahnos indicating the reference 35091 and the intended point of use.










Reviews