The Nonin Onyx® Vantage 9590 is the reference finger pulse oximeter for spot-check measurement of oxygen saturation (SpO₂) and pulse rate, with clinically proven accuracy even with movement and low perfusion. Manufactured in the USA, lead-free and latex-free, it incorporates PureSAT® technology, a large LED display readable from any angle, IP32 protection and a 4-year warranty. Available in blue (ref. 35084) and black (ref. 35085), suitable for fingers from 8 to 25.4 mm (from paediatric patient to large adult). For large orders, you can request a quote: consult our technical sales team.

International shipping. Import duties and taxes are payable by the recipient.

Reference
GM35084-F

Description

1. Commercial Introduction

The Nonin Onyx® Vantage 9590 finger pulse oximeter is the professional solution for quick and reliable monitoring of oxygen saturation (SpO₂) and pulse rate in any healthcare setting: consultations, emergencies, primary care, medical transport and professional home monitoring. It is the finger pulse oximeter whose accuracy and performance have been demonstrated through published clinical studies and scientific articles, and it is tested for use on all five fingers or toes. Available in blue (ref. 35084) and black (ref. 35085). For large orders, you can request a quote: ask our technical sales team for a personalised offer.

2. Technical explanation of the equipment

Pulse oximetry is a non-invasive optical technique that measures the functional oxygen saturation of arterial haemoglobin (SpO₂) by differential absorption of red and infrared light through the capillary bed of the finger. The photodetector captures the pulsatile component of the signal and the device immediately calculates the percentage of saturated haemoglobin and the pulse rate, displaying them on its large, bright LED display, readable from any angle, both day and night.

The Onyx® Vantage 9590 incorporates PureSAT® technology, which ensures accurate and fast readings even with patient movement, low perfusion or variable skin pigmentation. The device switches on automatically when the finger is inserted and allows up to 6,000 spot checks or 36 hours of continuous operation with two AAA alkaline batteries. Its construction, manufactured in the USA lead-free and latex-free, exceeds the requirements of the IP32 protection test against water ingress and withstands accidental drops (tested up to 50 drops), making it a robust device for daily use. It is supplied with a multilingual CD-ROM manual (includes Spanish) and comes with an industry-leading 4-year warranty.

3. Technical Specifications

Parameter Specification
Pulse rate range 18-321 lpm ±3 digits (20-250 lpm)
SpO₂ range 0-100% ±2 digits (70-100%)
SpO₂ in low perfusion 70-100% ±2 digits
Pulse rate in low perfusion 40-240 lpm ±3 digits

Available references

Reference Colour Sales unit
GM35084 Blue 1 pc
GM35085 Black 1 pc

Product data

Brand Nonin
Sales unit 1 pc
Device type Medical device (Medical device)
Device class II B
CND Z1203020408
GMDN 17148

4. Equivalences and Cross-References

This device corresponds to factory references 35084 (blue) and 35085 (black) under the Nonin brand (management SKU Cahnos GM35084 and GM35085). In Nonin’s reference documentation, the Onyx Vantage 9590 pulse oximeter is internationally identified as N-9590 (verified on the manufacturer’s website and GUDID 00849686072785).

There is no official equivalence table validated by the manufacturer that certifies a 1:1 substitution with models from other brands. At category level (finger pulse oximeter for spot-check measurement), models such as the medical ECONET ME10 (ref. 40.22-5205) or the ME5 (ref. 40.22-5206), as well as handheld pulse oximeters with catheter from the Nonin PalmSAT® 2500A family (ref. 35086), are considered comparable, subject to field-by-field technical validation. None should be considered interchangeable without verifying specifications, connectors and tender requirements; consult our technical department before any substitution.

5. Selection tips and variants of interest

  • Colour choice: the device is offered in blue (ref. 35084, SKU GM35084) and black (ref. 35085, SKU GM35085); it is the same technology, so the choice is based on preference or your department’s internal coding.
  • Population: a single pulse oximeter covers from paediatric patient to large adult thanks to its finger fit range of 8 to 25.4 mm, tested for fingers, thumbs and toes.
  • Intended use: it is designed for quick and reliable spot-check measurements; for continuous monitoring with catheter, alarms and memory, consider the Nonin PalmSAT® 2500A handheld pulse oximeter (ref. 35086) from our range.
  • Power supply: it operates with two AAA alkaline batteries; use quality batteries and remove them if the device is to remain unused for a long time to extend its service life.
  • Hygiene and maintenance: clean the sensor pads between patients following the manufacturer’s indications; the lead-free and latex-free construction, together with IP32 protection, facilitates its use in demanding environments.
  • Warranty: the device includes a 4-year warranty, a benchmark in the sector.

Additional information

Color

blue, black

Model

Onyx® Vantage 9590 (N-9590)

Manufacturer reference

35084 (blue) / 35085 (black)

Set type

Finger pulse oximeter for spot-check measurement

Technology

PureSAT®

Measured parameters

SpO₂ and pulse rate

SpO2 range

0-100% (±2 digits in 70-100%)

Pulse rate range

18-321 lpm (±3 digits in 20-250 lpm)

Spo2 low perfusion

70-100% ±2 digits

Pulse rate low perfusion

40-240 lpm ±3 digits

Population

Paediatric to large adult (finger from 8 to 25.4 mm)

Power supply

2 AAA alkaline batteries

Battery life

Up to 6,000 spot checks or 36 hours of continuous operation

Protection

IP32 (water ingress); withstands up to 50 drops

Materials

Lead-free (Pb) and latex-free

Warranty

4 years

Manual

Multilingual CD-ROM (GB, FR, IT, DE, ES, PT, GR, NL, PL, NO, FI, DK, SE)

Device type

Medical device (Medical device)

CND code

Z1203020408

GMDN code

17148

Presentacion

Unit

Tipo dispositivo

Medical device

Clase sanitaria

II b

Pais fabricacion

USA

Documentation

📄 DatasheetEnglish PDF
📎 Label / packagingLabel Box PDF · Label Box PDF
📜 Declaration of conformityMultilingüe PDF
📜 CE certificateDownload PDF
📜 ISO 9001 / 13485 certificatesMultilingüe PDF

Reviews

There are no reviews yet.

Be the first to review “Nonin Onyx® Vantage 9590 finger pulse oximeter | SpO₂ and pulse rate monitor with PureSAT® technology – Refs. 35084 (blue) and 35085 (black)”

Your email address will not be published. Required fields are marked *