We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Disposable SpO2 catheter for neonates and adults (Ref. 35109) for pulse oximeters 32902 and 35100 – Single-use with 70 cm cable

11,40 €

Disposable SpO2 pulse oximetry catheter valid for adult patients (>40 kg, finger placement) and neonates (<3 kg, foot placement), compatible with pulse oximeters Ref. 32902 and 35100. Single-use sensor with integrated 70 cm cable that prevents cross-contamination between patients, indicated for clinics, emergency departments, paediatrics, medical transport and monitoring of oxygen saturation and pulse rate. Requires extension cable Ref. 35108 (2 m), not included, for connection to the device. Medical device class II B (CND C900301) and sold per unit (1 pc). For large orders you can request a quote: consult our technical-commercial department.

Sales unit: 1 unidad
Minimum order for products shipped from Italy: 150,00 € excluding VAT (can be combined)

Delivery time: 15 days

International shipping. Import duties and taxes are payable by the recipient.

Reference
GM35109

Description

1. Commercial Introduction

The disposable SpO2 catheter ref. 35109 is the hygienic and practical solution for monitoring oxygen saturation and pulse rate in two very different patient profiles: adults over 40 kg and neonates under 3 kg. As a single-use sensor, it eliminates the need for cleaning and disinfection between patients and reduces the risk of cross-contamination in clinics, emergency departments, paediatrics, medical transport and home care. It is sold per unit; our technical-commercial team will advise you on volumes, lead times and conditions for institutional orders. For large orders you can request a quote.

2. Technical explanation of the probe

The SpO2 catheter is the sensing element of the pulse oximeter: it incorporates red and infrared light emitters and a photodetector which, placed on either side of the capillary bed, measure the differential absorption of haemoglobin. From the pulsatile component of the signal, the device non-invasively calculates oxygen saturation (SpO2) and pulse rate.

This reference is a single-use dual-application sensor: it can be used as a finger catheter in adult patients over 40 kg or as a foot catheter in neonates under 3 kg. It incorporates an integrated 70 cm cable and requires, for connection to the pulse oximeter, the 2 m extension cable Ref. 35108 (not included). It is designed to work with the equipment Ref. 32902 and 35100, guaranteeing direct compatibility with the connector and the manufacturer’s electronic protocol.

3. Technical Specifications

Manufacturer GIMA
Manufacturer reference 35109
Product type Disposable SpO2 catheter (single-use)
Population Adult >40 kg (finger) / Neonate <3 kg (foot)
Use Disposable (single-use)
Cable length 70 cm
Extension cable required Ref. 35108 – 2 m (not included)
Compatibility Pulse oximeters Ref. 32902 and 35100
Sales unit 1 pc (1 unit)
Device type Medical device (Medical device)
Device class II B
CND C900301
EAN 6945040101789

4. Equivalences and Cross-References

This catheter corresponds to reference 35109, designed for the pulse oximeters Ref. 32902 and 35100. No validated equivalence table has been found in reliable sources confirming 1:1 interchangeability with SpO2 sensors from other manufacturers (Nonin, Masimo, Nellcor, etc.), since compatibility depends on the connector and the electronic protocol of each device. It is recommended to always verify the connector and sensor specifications with the Cahnos technical department before considering replacement with a catheter from another brand.

For use with these devices, the extension cable Ref. 35108 (2 m) is essential. Within the same family of pulse oximetry accessories there are other catheters of comparable reference: the reusable adult catheter (ref. 35105), the reusable paediatric catheter 10-40 kg (ref. 35106) and the reusable neonatal catheter 3-10 kg (ref. 35107).

5. Selection tips and variants of interest

Take into account the patient’s weight range: this catheter is suitable for adults over 40 kg (placement on the finger) and neonates under 3 kg (placement on the foot); for other weight ranges consider the specific paediatric and neonatal catheters in the range. Remember to order the 2 m extension cable 35108 together with the catheter, as it is necessary to connect the sensor to the pulse oximeter 32902 or 35100.

As it is a single-use sensor, check stock rotation and consumption needs per patient according to the activity volume of your facility. Contact the Cahnos technical-commercial team to confirm exact compatibility with your equipment fleet, availability and conditions for volume orders.

Additional information

Manufacturer reference

35109

Product type

Disposable SpO2 catheter (single-use)

Use

Disposable (single-use)

Population

Adult >40 kg (finger) / Neonate

Cable length

70 cm

Extension cable required

Yes, ref. 35108 (2 m), not included

Compatibility

Pulse oximeters ref. 32902 and 35100

Sales unit

1 pc (1 unit)

Device type

Medical device (Medical device)

CND code

C900301

EAN

6945040101789

Presentacion

Unit

Tipo dispositivo

Medical device

Clase sanitaria

II b

Documentation

📄 DatasheetEnglish PDF
📎 Label / packagingLabel Box PDF
📜 Declaration of conformityEnglish PDF
📜 CE certificateMultilingüe PDF
📜 ISO 9001 / 13485 certificatesMultilingüe PDF

Reviews

There are no reviews yet.

Be the first to review “Disposable SpO2 catheter for neonates and adults (Ref. 35109) for pulse oximeters 32902 and 35100 – Single-use with 70 cm cable”

Your email address will not be published. Required fields are marked *