Chison P3-A Phased Array Probe (3.0 MHz) with CW + TDI for Portable Ultrasound Scanner CHISON ECO6 – Cardiology | Ref. GM33859

2.612,50 €

CHISON P3-A phased array probe for the portable ECO6 ultrasound scanner, with a cardiac package that optionally incorporates continuous wave Doppler (CW) and tissue Doppler (TDI). Main frequency of 3.0 MHz and working range of 2.5 to 4.5 MHz, specific for cardiology applications: detection of high-velocity blood flows and assessment of myocardial contractile and relaxation function. Original manufacturer transducer (ref. 33859) and marketed by Cahnos as GM33859. Class II A medical device, sales unit 1 pc. For large orders you can request a quote: consult our technical-commercial team.

Sales unit: 1 unidad
Minimum order for products shipped from Italy: 150,00 € excluding VAT (can be combined)

Delivery time: 15 days

International shipping. Import duties and taxes are payable by the recipient.

Reference
GM33859

Description

1. Commercial Introduction

The CHISON P3-A phased array probe is the reference transducer for cardiac examination with your portable CHISON ECO6 ultrasound scanner, distributed in Spain under reference 33859 (SKU Cahnos GM33859). It is an original manufacturer accessory, verified to guarantee maximum electrical, mechanical and software compatibility with your equipment, reliable image quality and a long service life. This package expands the cardiac diagnostics of your ECO6 with the P3-A probe and, optionally, with two advanced functions: continuous wave Doppler (CW) and tissue Doppler (TDI), ideal for assessing high-velocity flows and myocardial wall motion.

2. Technical explanation

The phased array probe has a reduced active aperture that generates a triangular image sector, making it especially suitable for scanning through the intercostal spaces and obtaining classic cardiac views (parasternal, apical and subcostal) with an excellent resolution-to-penetration ratio. With a main frequency of 3.0 MHz and a working range of 2.5 to 4.5 MHz, it is optimised for adult cardiology.

The continuous wave Doppler (CW) is an optional function that detects high-velocity blood flows and provides the clinician with additional relevant information for diagnosis. The tissue Doppler (TDI) is an echocardiography technique that directly measures myocardial velocity: systolic TDI measurements assess the contractile function of the left and right ventricles, while diastolic TDI values reflect myocardial relaxation.

3. Technical Specifications

Catheter features

Parameter Specification
CHISON code P3-A
Catheter type Phased array
Main frequency 3.0 MHz
Frequency range (MHz) 2.5 / 4.5
Applications Cardiology
Optional functions Continuous wave Doppler (CW) and tissue Doppler (TDI)

Product data

Brand Chison
Manufacturer reference 33859
SKU Cahnos GM33859
Sales unit 1 pc
Device type Medical device (Medical device)
Device class II A
CND Z11040182
EAN 6945121407427

Description of the optional functions

  • Continuous wave Doppler (CW) – optional: detects high-velocity blood flow and helps the physician in diagnosis by providing additional clinical information.
  • Tissue Doppler (TDI) – optional: echocardiography technique that directly measures myocardial velocity; systolic TDI measurements assess the contractile function of the ventricles and diastolic values reflect myocardial relaxation.

4. Equivalences and Cross-References

This probe is supplied under reference 33859 and is marketed on Cahnos under code GM33859, corresponding to the original CHISON P3-A code; both references are interchangeable when ordering the product. There is no official 1:1 equivalence table with other manufacturers validated by CHISON for this specific reference; for any replacement or tender, always verify the compatibility of the transducer with your equipment in the manufacturer’s official technical data sheet. Within the same range of probes for CHISON portable ultrasound scanners of the ECO series, the catalogue includes the linear probe L7M-A (ref. 33999), the 9.0 MHz linear probe L7S-A (ref. 33871), the convex probe C3-A (ref. 33998), the microconvex probes MC6-A (ref. 33997) and MC3-A (ref. 33874), the microconvex transvaginal probe V6-A (ref. 33872) and the transrectal probe R7-A (ref. 33873). As the host equipment, the CHISON ECO6 ultrasound scanner is identified by reference 33858.

5. Selection tips and variants of interest

Select this P3-A phased array probe if your activity focuses on cardiac examination with a portable CHISON ECO6 ultrasound scanner. Always confirm that your equipment corresponds to the ECO6 model before incorporating it, and consider activating the optional CW (high-velocity flows) and TDI (myocardial velocity) functions if your practice requires advanced functional analysis of the heart. If your work is oriented towards superficial tissues or small parts, consider a high-frequency linear probe; for the abdomen and deep organs, a convex or microconvex probe; and for obstetrics, gynaecology or urology, the transvaginal or transrectal probes compatible with your equipment. For large orders you can request a quote: tell our technical-commercial department your application and volume and we will advise you without obligation to configure the most suitable combination of probes for your clinical needs.

Additional information

Manufacturer reference

33859

CHISON code

P3-A

Catheter type

Phased array

Main frequency

3.0 MHz

Frequency range

2.5 / 4.5 MHz

Application

Cardiology

Compatibility

Portable ultrasound scanner CHISON ECO6

Optional functions

Continuous wave Doppler (CW) and tissue Doppler (TDI)

Device type

Medical device (Medical device)

CND code

Z11040182

EAN

6945121407427

Presentacion

Unit

Tipo dispositivo

Medical device

Clase sanitaria

II a

Documentation

📄 DatasheetEnglish PDF
📎 Label / packagingLabel Prodotto PDF
📜 Declaration of conformityEnglish PDF
📜 CE certificateDownload PDF
📜 ISO 9001 / 13485 certificatesMultilingüe PDF