Description
Introduction
The Specomed 4 mm otoscope speculum (Ref. 2470040A) is the reference disposable consumable for otoscopic examination in adult patients. Each unit is used only once and then discarded, eliminating reprocessing between patients and minimising the risk of cross-contamination in primary care, ENT, paediatrics and emergency departments.
Compatible with the most widespread otoscopes on the European market —Heine, KaWe and P Petit—, it is a versatile, economical solution with CE marking as a Class I medical device.
Technical product explanation
The ear speculum attaches to the head of the otoscope and acts as a funnel for transmitting light and image. Its distal opening of 4 mm is the standard size for adult ear canals, allowing proper inspection of the tympanic membrane with minimal manipulation.
Made of high-impact polystyrene (PS/HIPS) with a wall thickness of 0.5 mm, it maintains the necessary rigidity for insertion without deforming, avoids sharp edges and preserves the light transmission of the otoscope. It is a medical device Class I in accordance with RD 1591/2009 and Directives 93/42/EEC and 2007/47/EC, latex-free, non-sterile and with a temporary use duration of less than 30 minutes.
Technical specifications
| Characteristic | Detail |
|---|---|
| Manufacturer reference | 24 700 40A |
| EAN (pharmacy) | 3401040826211 |
| Distal opening | 4 mm |
| Material | Impact-resistant polystyrene (PS/HIPS) |
| Latex content | Exempt |
| Classification | Class I — Medical device |
| Use | Single-use, non-sterile |
| Use duration | Temporary (less than 30 minutes) |
| Presentation | Box of 250 units |
| GMDN code | 35348 |
| ANSM registration number | BI-07823-95 |
| Expiry | Not applicable |
| Storage | Dry and clean, away from direct sunlight (from -10 °C to +40 °C) |
Compatibility with otoscopes
| Brand | Indicative compatible models |
|---|---|
| Heine | Mini, Mini 3000, K180, BETA (127M), BETA (200/400), ALLSPEC |
| KaWe | Eurolight F.O., Piccolight C / F.O. / LED, Combilight F.O. |
| P Petit | Brand models cited by the manufacturer |
Equivalences and cross-references
Equivalent manufacturer references have been cross-checked by category in official sources (manufacturer catalogue, GUDID/FDA). All match in diameter (4 mm), material (polystyrene), single-use and absence of latex, but as they are proprietary designs of each brand, they are not considered 1:1 interchangeable for mechanical fit purposes.
| Manufacturer / Brand | Family / Model | Reference Code / SKU | Equivalence Level | Technical Differences / Remarks |
|---|---|---|---|---|
| HEINE | AllSpec Disposable Tips, adult Ø 4 mm | B-000.11.127 (bag of 1,000 units) / B-000.11.152 (dispenser of 250 units) | Comparable by category (not interchangeable 1:1) | Styrol material with at least 94% recycled content; dark grey colour; proximal opening 17.5 mm and length 30.5 mm; HEINE’s own positive fit; class I. Verified in official HEINE technical data sheet (March 2024) and GUDID (GTIN 04053755191055). |
| KaWe | Disposable ear funnels Ø 4.0 mm (large size) | 01.71221.002 (box of 1,000 units) / 01.71222.002 (box of 100 units) | Comparable by category (not interchangeable 1:1) | Anthracite/grey colour; factory format in bulk or in box; designed for EUROLIGHT F.O., COMBILIGHT F.O. and PICCOLIGHT C/F.O.; bayonet fitting KaWe. Verified on official KaWe website and GUDID (GTIN 04030155000675). |
| GIMA | Disposable standard speculum Ø 4 mm for Heine/KaWe | 31505 (box of 1,000 units, 20 packs of 50) | Comparable by category (not interchangeable 1:1) | Black colour; GTIN 13701126705100; designed for Heine Beta 100, K100, Eurolight and KaWe C10, C30, Combilight C10; class I. Verified in official GIMA catalogue. |
The brand P Petit appears in the official documentation of the manufacturer Specomed as compatible for these references, but no validated public speculum code for that brand has been found in open sources. Other similar brands in the sector for this size (Riester and Welch Allyn) use their own fixation systems or non-disposable formats, so their specific references must be verified against each manufacturer’s official catalogue before replacement. There is no equivalence table validated by the manufacturer that includes P Petit with its own code; consult the technical department before use in tenders.
Selection tips and variants of interest
For paediatric patients or those with narrow ear canals, the 2.5 mm speculum from the same Specomed range is recommended (Ref. 2470025A and variants). In high-volume centres, the presentation in bag of 1,000 units (Ref. 2470040) offers a better cost per unit and reduces warehouse restocking.
Always check the fixation diameter of your otoscope head before choosing the reference: Mini-Heine and compatible models share the same coupling system, while otoscopes of the Welch Allyn type use a different socket. For optimal hygiene, use a new speculum for each patient and each ear, and dispose of it in the appropriate medical waste container.