Description
Clinical monitor for exhaled nitric oxide (FeNO)
The FeNO monitor is the ideal tool for pulmonologists, allergists and primary care professionals who need to objectively, quickly and non-invasively assess airway inflammation. Thanks to its 8-inch colour TFT LED touchscreen, the device offers an intuitive interface that simplifies performing the test and reading results during the consultation, improving the experience for both the professional and the patient.
How does exhaled nitric oxide analysis work?
The exhaled fraction of nitric oxide (FeNO) is an internationally recognised biomarker (ATS/ERS and GEMA guidelines) of type 2 eosinophilic inflammation in the airway. During the test, the patient exhales in a controlled manner through the mouthpiece and the device quantifies in parts per billion (ppb) the concentration of nitric oxide present in the exhaled air. High FeNO values indicate an increase in respiratory inflammation, allowing confirmation of the asthma diagnosis, prediction of response to inhaled corticosteroids, assessment of treatment adherence and anticipation of possible exacerbations.
This device performs three types of measurement for a complete assessment of the respiratory tree: FeNO (exhaled bronchial nitric oxide), CaNO (alveolar nitric oxide, characteristic of the small airway) and FnNO (nasal nitric oxide). The standard exhalation is 10 seconds, with a reduced 6-second mode designed for children aged 6 to 10 years.
Technical specifications
Measurement parameters
| Parameter | Specification |
| Measurement range | 1 to 3500 ppb of exhaled nitric oxide |
| Measurement types | FeNO, CaNO and FnNO |
| Accuracy | ±5 ppb for values < 50 ppb; relative margin of up to 10% for higher values |
| Exhalation duration | 10 seconds standard; 6 seconds in paediatric mode (children aged 6 to 10 years) |
| Memory | 500,000 measurements for prolonged clinical follow-up |
Display and operation
| Parameter | Specification |
| Display | 8-inch colour TFT LED touchscreen |
| Languages | Spanish, Chinese, French, English, Italian, Polish, Portuguese, Russian and Turkish |
| Power supply | Alternating current AC 100-240 V |
| Internal battery | Rechargeable 2200 mAh, up to 1 hour of continuous use after 8 hours of charging |
| Operating temperature | 5 to 40 °C |
| Operating relative humidity | 15 % to 80 % |
Safety and regulations
| Parameter | Specification |
| Certification | CE marking as a medical device |
| Electrical protection | Class I |
| Degree of protection against liquids | IPX1 |
Equivalences and cross-references
FeNO monitors have become established in clinical practice as the reference complementary test for asthma management, alongside spirometry and PEF/FEV1 measurement. Commercial references in the same segment used in the European and international market include, among others, the Sunvou TM1100/TM1101 series (bronchial FeNO50 measurement with electrochemical sensor), the Sunvou CA2122 device (all-in-one with FeNO50, CaNO, FnNO, H2S and CO) and the Sunvou TM2120 portable touchscreen model; as well as the benchtop analysers NObreath (Bedfont), NIOX VERO (Circassia) and CLD 88 sp (EcoMedics), used in comparative studies of clinical equivalence with the values obtained by this type of equipment.
This monitor is complemented in the Cahnos catalogue by the professional spirometers from the Datospir range (Aira T, Micro A and Touch models), peak flow measurement devices for asthma and the rest of the respiratory diagnostic solutions, allowing a complete lung function unit to be configured.
Selection tips and variants of interest
1. Clinical interpretation of results: according to ATS guidelines, in adults FeNO values below 25 ppb are considered low, between 25 and 50 ppb intermediate, and above 50 ppb high. In children, the cut-off points are set at 20 and 35 ppb. Ensure that patient values are recorded together with the date, time and medication for effective follow-up.
2. Paediatric population: the reduced 6-second exhalation mode facilitates the test in children aged 6 to 10 years, making this monitor especially suitable for paediatric and child allergy consultations.
3. Integration with other tests: for a complete functional assessment of the respiratory patient, it is recommended to combine FeNO measurement with spirometry and bronchodilator testing. Consult the Cahnos range of spirometers and flow meters compatible with this diagnostic unit.
4. Consumables and maintenance: measurement is performed through patient mouthpieces or filters; it is recommended to check the availability of consumables and the sensor calibration plan to ensure repeatability of readings over time.
5. Environmental conditions: the device operates correctly between 5 and 40 °C with a relative humidity of 15 % to 80 %. Keep the monitor within these ranges and recharge the 2200 mAh battery periodically to ensure its availability when mobile.